文献速递甲状腺疾病

基于人工智能的计算机辅助诊断系统用于超声诊断和表征甲状腺结节:初步临床评估

A Computer-Aided Diagnosis System Using Artificial Intelligence for the Diagnosis and Characterization of Thyroid Nodules on Ultrasound: Initial Clinical Assessment.
PubMed 文献 · Thyroid · 2017-02-28

该研究连续纳入2015年11月至2016年2月具有明确良恶性诊断的甲状腺结节患者,由一名经验丰富的放射科医生评估超声特征,另一名放射科医生使用人工智能计算机辅助诊断(CAD)系统评估同一结节,比较两者的诊断性能和超声特征一致性。共纳入89例患者的102个甲状腺结节,其中良性59个(57.8%)、恶性43个(42.2%)。CAD系统灵敏度与经验丰富的放射科医生相似(90.7% vs 88.4%,p>0.99),但特异度和AUROC曲线下面积较低(特异度:74.6% vs 94.9%,p=0.002;AUROC:0.83 vs 0.92,p=0.021)。

要点

  • CAD系统诊断恶性甲状腺结节的灵敏度与经验丰富的放射科医生相似(90.7% vs 88.4%,p>0.99)。
  • CAD系统特异度低于经验丰富的放射科医生(74.6% vs 94.9%,p=0.002)。
  • CAD系统对结节成分、方位、回声和海绵状特征与放射科医生呈高度一致,边缘呈一般一致。

核心结论

  • CAD系统诊断恶性甲状腺结节的灵敏度与经验丰富的放射科医生相当,但特异度和准确度低于经验丰富的放射科医生。
  • CAD系统在甲状腺结节特征表征方面与经验丰富的放射科医生具有可接受的一致性。

研究设计与样本

  • 连续纳入2015年11月至2016年2月具有明确良恶性诊断的甲状腺结节患者。
  • 一名经验丰富的放射科医生审阅甲状腺结节超声图像特征,另一名放射科医生使用CAD系统评估同一结节并提供超声特征及良恶性诊断。
  • 比较经验丰富的放射科医生与CAD系统之间的诊断性能和超声特征一致性。

主要发现

  • 共纳入89例患者的102个甲状腺结节,其中良性59个(57.8%),恶性43个(42.2%)。
  • CAD系统灵敏度与经验丰富的放射科医生相似(90.7% vs 88.4%,p>0.99)。
  • CAD系统特异度低于经验丰富的放射科医生(74.6% vs 94.9%,p=0.002)。
  • CAD系统AUROC曲线下面积低于经验丰富的放射科医生(0.83 vs 0.92,p=0.021)。
  • 放射科医生与CAD系统对超声特征分类的一致性:成分κ=0.659,方位κ=0.740,回声κ=0.733,海绵状κ=0.658,边缘κ=0.239。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: An initial clinical assessment is described of a new, commercially available, computer-aided diagnosis (CAD) system using artificial intelligence (AI) for thyroid ultrasound, and its performance is evaluated in the diagnosis of malignant thyroid nodules and categorization of nodule characteristics. METHODS: Patients with thyroid nodules with decisive diagnosis, whether benign or malignant, were consecutively enrolled from November 2015 to February 2016. An experienced radiologist reviewed the ultrasound image characteristics of the thyroid nodules, while another radiologist assessed the same thyroid nodules using the CAD system, providing ultrasound characteristics and a diagnosis of whether nodules were benign or malignant. The diagnostic performance and agreement of US characteristics between the experienced radiologist and the CAD system were compared. RESULTS: In total, 102 thyroid nodules from 89 patients were included; 59 (57.8%) were benign and 43 (42.2%) were malignant. The CAD system showed a similar sensitivity as the experienced radiologist (90.7% vs. 88.4%, p > 0.99), but a lower specificity and a lower area under the receiver operating characteristic (AUROC) curve (specificity: 74.6% vs. 94.9%, p = 0.002; AUROC: 0.83 vs. 0.92, p = 0.021). Classifications of the ultrasound characteristics (composition, orientation, echogenicity, and spongiform) between radiologist and CAD system were in substantial agreement (κ = 0.659, 0.740, 0.733, and 0.658, respectively), while the margin showed a fair agreement (κ = 0.239). CONCLUSION: The sensitivity of the CAD system using AI for malignant thyroid nodules was as good as that of the experienced radiologist, while specificity and accuracy were lower than those of the experienced radiologist. The CAD system showed an acceptable agreement with the experienced radiologist for characterization of thyroid nodules.

来源:Thyroid,查看原文。版权归原作者所有。

引用

  1. Choi YJ, Baek JH, Park HS, et al. A Computer-Aided Diagnosis System Using Artificial Intelligence for the Diagnosis and Characterization of Thyroid Nodules on Ultrasound: Initial Clinical Assessment. Thyroid. 2017. PMID: 28071987. doi:10.1089/thy.2016.0372

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。