糖尿病外周动脉疾病床旁诊断工具的多中心准确性研究
该前瞻性多中心诊断准确性研究纳入604例糖尿病患者,以CTA或MRA为参考标准,评估五种床旁测试对PAD的诊断准确性。结果显示所有床旁测试敏感性均低, audible Doppler为36%,visual Doppler为42%,TBPI为55%,ABPI为41%,运动ABPI为41%。结论认为这些工具在糖尿病人群中诊断性能差,不应视为准确诊断工具。
要点
- 在糖尿病患者中,五种常用床旁测试诊断PAD的敏感性均低。
- TBPI敏感性55%为最高,但仍不足以作为准确诊断工具。
- ABPI和运动ABPI敏感性均为41%,audible Doppler仅36%。
核心结论
- 在糖尿病患者中,visual Doppler、audible Doppler、ABPI、TBPI和运动ABPI对PAD的诊断性能差,不应视为准确诊断工具。
研究设计与样本
- 前瞻性多中心诊断准确性研究,在英国16个中心开展,纳入604例年龄≥18岁、有糖尿病史且无CTA或MRA禁忌的参与者,最终536例完成研究并有有效参考影像。
主要发现
- PAD在37%的参与者中被识别。
- audible Doppler敏感性为36%(95% CI 27-45)。
- visual Doppler敏感性为42%(95% CI 33-51)。
- TBPI敏感性为55%(95% CI 46-64)。
- ABPI敏感性为41%(95% CI 32-50),运动ABPI敏感性为41%(95% CI 31-51)。
关键数值与推荐
- 参考标准为CTA或MRA,采用ANGIO评分系统,以≥50%狭窄定义PAD。
- 主要结局为测试敏感性。
临床怎么用
- 在糖尿病患者中,不应将上述床旁测试视为PAD的准确诊断工具,需谨慎解读其结果。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: Accurate diagnosis of peripheral arterial disease (PAD) in people with diabetes is critical, but the accuracy of common bedside tests remains uncertain. This study evaluated the diagnostic accuracy of five bedside tests-ankle brachial pressure index (ABPI), exercise ABPI, toe brachial pressure index (TBPI), visual Doppler, and audible Doppler. Results were compared against the reference standard of computed tomography angiography (CTA) or magnetic resonance angiography (MRA). RESEARCH DESIGN AND METHODS: A prospective multicenter diagnostic accuracy study was conducted across 16 sites in the U.K. Participants aged ≥18 years, with a history of diabetes (symptomatic and asymptomatic), without contraindications to CTA or MRA, PAD status known on imaging, or a known history of PAD intervention, were eligible to partake. Patients were recruited from both primary and secondary care. Radiologists, blinded to index test results, used the ANGIO scoring system, with ≥50% stenosis defining PAD. The primary outcome was test sensitivity. RESULTS: From April 2022 to November 2023, 604 participants were enrolled; 536 completed the study with valid reference imaging. PAD was identified in 37% of participants. Sensitivity was low across all bedside tests: audible Doppler (36%, 95% CI 27-45), visual Doppler (42%, 95% CI 33-51), TBPI (55%, 95% CI 46-64), ABPI (41%, 95% CI 32-50), and exercise ABPI (41%, 95% CI 31-51). CONCLUSIONS: In people with diabetes, visual Doppler, audible Doppler, ABPI, TBPI, and exercise ABPI demonstrated poor diagnostic performance for PAD and should not be considered as accurate diagnostic tools in this population.
引用
- Normahani P, Burgess L, Graham C, et al. Diagnostic Tools to Establish the Presence of Peripheral Arterial Disease in People With Diabetes (DMPAD): A Multicenter Comparative Diagnostic Accuracy Study. Diabetes Care. 2026. PMID: 42525838. doi:10.2337/dc25-1693
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。