唾液11-脱氢地塞米松作为地塞米松吸收标志物的效用
该研究在90对过夜1mg地塞米松抑制试验后的血清和唾液样本中,用LC-MS/MS检测血清皮质醇、地塞米松及唾液皮质醇、可的松、地塞米松和11-脱氢地塞米松。结果发现血清地塞米松与唾液11-脱氢地塞米松呈正相关(R²=0.75),而血清与唾液地塞米松相关性差(R²=0.135)。唾液11-脱氢地塞米松有望作为地塞米松吸收的替代标志物,改善患者路径。
要点
- 血清地塞米松与唾液11-脱氢地塞米松正相关(R²=0.75)。
- 血清与唾液地塞米松相关性差(R²=0.135)。
- 唾液11-脱氢地塞米松或可替代血清地塞米松评估吸收。
核心结论
- 血清地塞米松与唾液11-脱氢地塞米松呈正相关,提示后者可作为地塞米松吸收的替代标志物。
研究设计与样本
- 研究收集90对过夜1mg地塞米松抑制试验后的0900h血清和唾液样本,采用LC-MS/MS检测血清皮质醇和地塞米松,并开发新型LC-MS/MS法检测唾液皮质醇、可的松、地塞米松和11-脱氢地塞米松,用Pearson相关系数评估相关性。
主要发现
- 血清与唾液地塞米松相关性差(R²=0.135)。
- 唾液地塞米松与11-脱氢地塞米松相关性差(R²=0.163)。
- 血清地塞米松与唾液11-脱氢地塞米松呈正相关(R²=0.75),高浓度时相关性呈曲线且变异增大。
临床怎么用
- 患者可自行给药并在方便时收集0900h唾液样本,邮寄分析,有望改善当前患者路径。
局限性
- 高浓度地塞米松时血清与唾液11-脱氢地塞米松相关性呈曲线且变异增大。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: The 1 mg overnight dexamethasone suppression test (ONDST) is recommended for the investigation of hypercortisolism and adrenal incidentalomas. Measurement of cortisol and dexamethasone (DXM) has been shown to improve diagnostic sensitivity of the ONDST. Recent work has shown that salivary cortisone collection can be undertaken at home replacing serum sampling, but previous studies have found poor performance of salivary DXM after the ONSDT. Herein we introduce the concept of measuring 11-dehydrodexamethasone (11-DHD): a DXM metabolite produced in the salivary duct by metabolism of 11β-hydroxysteroid dehydrogenase type 2, as a surrogate marker for DXM absorption. METHODS: Paired 0900h serum and saliva samples (n=90) were collected post-ONDST. Independent liquid chromatography-tandem mass spectrometry (LC-MS/MS) assays were used to measure serum cortisol and DXM. A novel LC-MS/MS assay was developed to measure salivary cortisol, cortisone, DXM and 11-DHD. Results were compared and correlations were assessed using Pearson's correlation coefficient. RESULTS: Serum and salivary DXM results exhibited a poor correlation (R-squared = 0.135). Salivary DXM and 11-DHD also correlated poorly (R-squared = 0.163). Serum DXM and salivary 11-DHD yielded a positive correlation with an R-squared of 0.75. CONCLUSION: The positive relationship between serum DXM and salivary 11-DHD is novel. At higher concentrations of DXM, the correlation becomes somewhat curvilinear and more variable. A similar relationship is seen between salivary cortisol and cortisone. The development of a salivary 11-DHD LC-MS/MS assay has the potential to improve the current patient pathway. Patients could administer the drug and collect a 0900h-saliva sample at their convenience, prior to posting for analysis.
引用
- Marshall DJ, Issa BG, Keevil BG, et al. The Utility of Salivary 11-Dehydrodexamethasone as a Marker of Dexamethasone Absorption. J Clin Endocrinol Metab. 2026. PMID: 42275605. doi:10.1210/clinem/dgag236
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。