亚临床甲减患者中巨TSH的患病率与临床特征
研究纳入1599例亚临床甲减患者,采用PEG沉淀法筛查巨TSH,发现4例(0.25%)存在巨TSH,其复合物涉及IgG、IgA和IgM。所有巨TSH患者此前均接受过LT4治疗且TSH仅轻度下降,其中3例甲状腺自身抗体阳性。提示在低抗体-TSH结合亲和力且自身抗体阳性者中TSH水平可能波动,增加诊治难度。
要点
- 亚临床甲减患者中巨TSH患病率为0.25%(4/1599)。
- 巨TSH复合物可涉及IgG、IgA和IgM多种免疫球蛋白类型。
- 巨TSH患者LT4治疗仅使TSH轻度下降,且多伴甲状腺自身抗体阳性。
核心结论
- 巨TSH复合物包含多种免疫球蛋白类型,在低抗体-TSH结合亲和力且甲状腺自身抗体阳性的患者中TSH水平可能波动,使诊断和管理复杂化。
研究设计与样本
- 所有患者进行PEG沉淀法筛查,TSH回收率<20%者进一步行凝胶过滤色谱、蛋白G和Jacalin沉淀及干扰试验。
主要发现
- 4例患者(0.25%)在中性条件下显示高分子量TSH峰(>150 kDa),酸性条件下消失并转为天然分子量(约28 kDa),提示巨TSH。
- 巨TSH复合物在对应IgG、IgA和IgM的峰中被检测到,经蛋白G和Jacalin沉淀验证,无检测干扰证据。
- 所有4例巨TSH患者此前均接受LT4治疗,TSH仅轻度下降,其中3例TgAb和/或TPOAb阳性。
- PEG沉淀后TSH回收率在两名单体TSH丰富的患者中变异较大。
临床怎么用
- 对亚临床甲减患者,尤其甲状腺自身抗体阳性且LT4治疗后TSH下降不显著者,应警惕巨TSH可能。
- PEG沉淀法可作为巨TSH的初筛手段,TSH回收率<20%时需进一步验证。
局限性
- 研究为单中心、短时间连续纳入,巨TSH病例数少(4例),结论外推需谨慎。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Macro-thyrotropin (TSH) is a high molecular weight complex of TSH associated with apparently elevated levels of serum TSH, which can lead to an incorrect diagnosis of subclinical hypothyroidism. Given that levothyroxine (LT4) replacement is unnecessary in such cases, the accurate identification of macro-TSH based on clinical and laboratory findings is of particular importance. We aimed to determine the prevalence and clinical features of macro-TSH in patients with subclinical hypothyroidism evaluated after the introduction of TSH harmonization. PATIENTS AND METHODS: Between August and November 2023, we included 1599 consecutive patients with subclinical hypothyroidism (TSH > 4.23 mIU/L with normal fT4 levels) who were either untreated or receiving LT4 replacement monotherapy. Polyethylene glycol (PEG) precipitation was performed in all cases. Patients with TSH recovery of <20% underwent further evaluation, including gel filtration chromatography under neutral and acidic conditions, protein G and Jacalin precipitation assays, and a comprehensive battery of interference tests. RESULTS: Four patients (0.25%) showed high molecular-weight TSH peaks (>150 kDa) under neutral conditions that disappeared under acidic conditions, with a shift to the native molecular weight (approximately 28 kDa), indicating the initial presence of macro-TSH. The TSH complex was detected in peaks corresponding to IgG, IgA, and IgM. These findings were verified using Protein G and Jacalin precipitation assays, with no evidence of assay interference. Reevaluation of TSH recovery following PEG precipitation showed substantial variation in two patients who had abundant monomeric TSH compared with the high-molecular complex. All four patients with macro-TSH had previously received LT4 therapy, which resulted in a modest reduction in TSH levels, with three of these patients testing positive for TgAb and/or TPOAb. CONCLUSIONS: Macro-TSH complexes comprise several immunoglobulin isotypes. In cases with low antibody-TSH binding affinity and positive antithyroid autoantibodies, TSH levels may fluctuate during the clinical course, thereby complicating diagnosis and management.
引用
- Nishihara E, Fukata S, Imamura C, et al. Prevalence and Clinical Characteristics of Macro-TSH in Patients with Subclinical Hypothyroidism. Thyroid. 2026. PMID: 42236450. doi:10.1177/10507256261456988
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。