参加夏令营的1型糖尿病儿童和青少年中实时动态血糖监测的益处与准确性:第二年研究
2024年夏令营中评估Dexcom G7实时动态血糖监测(rt-CGM)在21例1型糖尿病儿童和52名医护人员中的有用性、推荐度及准确性,并与前一年使用的G6比较。G7在传感器插入、血糖变化可视化和便利性方面评分高,有用性和推荐度在营员中显著高于G6,医护人员评分两者几乎同等高。G7的MARD在营中为11.3%(G6为16.0%),营外为11.0%(G6为19.7%),营中血糖管理指标优于营外。
要点
- G7在营员中的有用性和推荐度显著高于前一年使用的G6,医护人员对两者评分几乎同等高。
- G7的MARD在营中为11.3%(G6为16.0%),营外为11.0%(G6为19.7%)。
- G7的血糖管理指标为7.44%(G6为8.04%),营中血糖管理指标优于营外。
核心结论
- G7在参与者中的有用性和推荐度评分高于G6,G7也表现出改善的准确性,被认为是夏令营环境中一种有用的rt-CGM工具。
- 由于医护人员的多方向努力,营中血糖管理显著改善。
研究设计与样本
- 2024年夏令营研究,从营前6天开始使用Dexcom G7测量传感器葡萄糖浓度,共21例1型糖尿病儿童和52名医护人员参与。
- 通过问卷评估有用性和推荐度,在营前6天和营中2天测量CGM相关指标。
主要发现
- G7在传感器插入、传感器葡萄糖变化可视化和营中便利性方面评分高,传感器葡萄糖值准确性评分相对较低。
- G7在营员中的有用性和推荐度显著高于前一年使用的G6,医护人员对两者评分几乎同等高。
- G7的MARD在营中为11.3%(G6为16.0%),营外为11.0%(G6为19.7%)。
- G7的变异系数在营中为34.4%(G6为60.3%),营外为35.9%(G6为63.1%)。
- G7的血糖管理指标为7.44%(G6为8.04%),营中血糖管理指标优于营外,图形分析也显示足够准确性。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
CONTEXT: In 2023, we employed Dexcom G6 for real-time continuous glucose monitoring (rt-CGM); it showed high usefulness but unsatisfactory accuracy in summer camp (camp) participants with type 1 diabetes. OBJECTIVE: To assess the usefulness, recommendation, and accuracy of a new rt-CGM system in camp participants in 2024. METHODS: Sensor glucose (SG) concentrations were measured by Dexcom G7 (G7) from 6 days prior to camp. Usefulness and recommendation were assessed by questionnaire. A total of 21 children with type 1 diabetes and 52 healthcare providers (HCPs) participated. CGM-associated metrics were measured 6 days prior to camp (off camp: 6 days) and during camp (on camp: 2 days). RESULTS: G7 was rated highly for its sensor insertion, visualization of SG variation, and convenience during camp. The SG value accuracy scored relatively low. G7's usefulness and recommendation among campers were significantly higher than those of G6, utilized the previous year, and they were both almost equally highly rated by HCPs. The mean absolute relative difference (MARD) was 11.3% (G6: 16.0%) on camp and 11.0% (G6: 19.7%) off camp. The coefficient of variation was 34.4% (G6: 60.3%) on camp and 35.9% (G6: 63.1%) off camp, while the glucose management indicator was 7.44% for G7 (G6: 8.04%). The glycemic management metrics on camp were better than those off camp. Graphical analyses also showed sufficient accuracy. CONCLUSION: G7 was rated higher in usefulness and recommendation than G6 among participants. G7 also exhibited improved accuracy and was considered a useful rt-CGM tool in a camp setting. Glucose management on camp was significantly improved because of the multi-directional efforts of the HCPs.
引用
- Kondo T, Senokuchi T, Yano M, et al. Benefits and Accuracy of Real-Time CGM in Children and Adolescents With Type 1 Diabetes Attending Summer Camp: Second Year. J Clin Endocrinol Metab. 2025. PMID: 40073408. doi:10.1210/clinem/dgaf160
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。