利用连续血糖监测早期识别亚洲人群妊娠期糖尿病及妊娠结局
研究纳入103名超重或肥胖的多族裔亚洲孕妇,孕早期佩戴盲法连续血糖监测(CGM)并在24-28周行通用妊娠期糖尿病(GDM)筛查。CGM衍生新参数预测GDM的曲线下面积为0.953,传统风险模型为0.722;新参数可显著区分初次剖宫产和大于胎龄儿。作者认为CGM在孕早期对预测GDM及不良妊娠结局有潜在临床价值。
要点
- 孕早期CGM衍生参数预测GDM的AUC为0.953,优于传统风险模型的0.722。
- CGM衍生新参数可显著区分初次剖宫产和大于胎龄儿。
- 作者认为CGM在孕早期对超重或肥胖人群预测GDM及不良妊娠结局有潜在临床价值。
核心结论
- 数据提示CGM在孕早期对预测GDM及不良妊娠结局有潜在临床价值,尤其在超重或肥胖个体中。
研究设计与样本
- 研究从一项医院前瞻性队列中招募103名超重或肥胖的多族裔亚洲孕妇,均在孕早期佩戴盲法CGM并在24-28孕周接受通用GDM筛查。
- 基于孕早期风险因素和CGM衍生参数选择模型,比较各自对GDM和妊娠结局的预测价值。
主要发现
- 共确诊18例GDM。
- CGM衍生新参数预测GDM的曲线下面积为0.953,传统风险模型为0.722。
- CGM衍生新参数可显著区分初次剖宫产和大于胎龄儿。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: We explored the potential value of continuous glucose monitoring (CGM) in early pregnancy in predicting gestational diabetes mellitus (GDM) and pregnancy outcomes. RESEARCH DESIGN AND METHODS: The study recruited 103 multiethnic Asian pregnant women with overweight or obesity from a hospital-based, prospective cohort. All of them had worn blinded CGM devices in early pregnancy and underwent the universal GDM screening at 24-28 gestation weeks. Models were selected based on early pregnancy risk factors and CGM-derived parameters to compare their respective predictive values for GDM and pregnancy outcomes. RESULTS: Eighteen GDM cases were ascertained. CGM-derived novel parameters demonstrated greater performance (e.g., area under the curve: 0.953 vs. 0.722) for predicting incident GDM compared with the model using traditional risks. Such novel CGM-derived parameters significantly differentiated primary cesarean and large-for-gestational age babies. CONCLUSIONS: Our data suggest CGM's potential clinical utility in the first trimester for predicting GDM and adverse pregnancy outcomes, particularly in individuals with overweight or obesity.
引用
- Lim BSY, Yang Q, Choolani M, et al. Utilizing Continuous Glucose Monitoring for Early Detection of Gestational Diabetes Mellitus and Pregnancy Outcomes in an Asian Population. Diabetes Care. 2024. PMID: 39235839. doi:10.2337/dc24-0944
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。