文献速递糖尿病

代谢组作为1型糖尿病运动最大有氧能力的诊断工具

The metabolome as a diagnostic for maximal aerobic capacity during exercise in type 1 diabetes.
PubMed 文献 · Diabetologia · 2024-04-25

研究纳入30例1型糖尿病受试者和30名对照组,进行45分钟坡度跑台步行并检测靶向代谢组。1型糖尿病组最大有氧能力(V̇O2peak)与HbA1c呈负相关(r2=0.17,p=0.024),静息血清苹果酸/丙酮酸比值对该组最大有氧能力具有诊断价值(ROC曲线AUC 0.867[95%CI 0.716,0.956])。

要点

  • 1型糖尿病组V̇O2peak与HbA1c呈负相关(r2=0.17,p=0.024)。
  • 1型糖尿病组静息血清苹果酸(倍数变化1.4,p=0.001)和乳酸(倍数变化1.22,p=1.23×10⁻⁵)升高。
  • 静息血清苹果酸/丙酮酸比值诊断1型糖尿病最大有氧能力的ROC曲线AUC为0.867(95%CI 0.716,0.956)。

核心结论

  • 血清代谢组可区分高和低最大有氧能力,并具有诊断潜力,有助于1型糖尿病有氧运动和体适能管理的个性化医疗方法。

研究设计与样本

  • 招募30例1型糖尿病受试者(病程≥3年)和30名对照者,两组年龄和性别无差异。
  • 根据峰值刺激C肽水平将受试者分为残余β细胞功能检测不到(<3 pmol/l)、低(3-200 pmol/l)和高(>200 pmol/l)三组。
  • 通过V̇O2peak测试评估最大有氧能力,所有受试者完成45分钟坡度跑台步行(60% V̇O2peak),在运动前、运动后即刻和恢复60分钟后采集静脉血。
  • 血清采用靶向代谢组学分析,代谢组数据采用多变量统计定义1型糖尿病运动的代谢表型,采用ROC曲线识别循环代谢组标志物。

主要发现

  • 1型糖尿病组最大有氧能力(V̇O2peak)与HbA1c呈负相关(r2=0.17,p=0.024)。
  • 静息血清三羧酸循环代谢物苹果酸(倍数变化1.4,p=0.001)和乳酸(倍数变化1.22,p=1.23×10⁻⁵)升高可区分1型糖尿病人群。
  • 血清酰基肉碱升高(AC C14:1,F值=12.25,p=0.001345;AC C12,F值=11.055,p=0.0018)是1型糖尿病人群运动代谢反应所特有。
  • C肽状态差异影响运动期间血清酰基肉碱的代谢反应(AC C18:1,杠杆值0.066;平方预测误差3.07)。
  • 静息血清苹果酸/丙酮酸比值对1型糖尿病人群最大有氧能力(V̇O2peak)具有诊断价值(ROC曲线AUC 0.867[95%CI 0.716,0.956])。

关键数值与推荐

  • 1型糖尿病组V̇O2peak与HbA1c呈负相关(r2=0.17,p=0.024)。
  • 静息血清苹果酸/丙酮酸比值诊断1型糖尿病最大有氧能力的ROC曲线AUC为0.867(95%CI 0.716,0.956)。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

AIMS/HYPOTHESIS: Our aim was to characterise the in-depth metabolic response to aerobic exercise and the impact of residual pancreatic beta cell function in type 1 diabetes. We also aimed to use the metabolome to distinguish individuals with type 1 diabetes with reduced maximal aerobic capacity in exercise defined by V ˙ O 2peak . METHODS: Thirty participants with type 1 diabetes (≥3 years duration) and 30 control participants were recruited. Groups did not differ in age or sex. After quantification of peak stimulated C-peptide, participants were categorised into those with undetectable (<3 pmol/l), low (3-200 pmol/l) or high (>200 pmol/l) residual beta cell function. Maximal aerobic capacity was assessed by V ˙ O 2peak test and did not differ between control and type 1 diabetes groups. All participants completed 45 min of incline treadmill walking (60% V ˙ O 2peak ) with venous blood taken prior to exercise, immediately post exercise and after 60 min recovery. Serum was analysed using targeted metabolomics. Metabolomic data were analysed by multivariate statistics to define the metabolic phenotype of exercise in type 1 diabetes. Receiver operating characteristic (ROC) curves were used to identify circulating metabolomic markers of maximal aerobic capacity ( V ˙ O 2peak ) during exercise in health and type 1 diabetes. RESULTS: Maximal aerobic capacity ( V ˙ O 2peak ) inversely correlated with HbA1c in the type 1 diabetes group (r2=0.17, p=0.024). Higher resting serum tricarboxylic acid cycle metabolites malic acid (fold change 1.4, p=0.001) and lactate (fold change 1.22, p=1.23×10-5) differentiated people with type 1 diabetes. Higher serum acylcarnitines (AC) (AC C14:1, F value=12.25, p=0.001345; AC C12, F value=11.055, p=0.0018) were unique to the metabolic response to exercise in people with type 1 diabetes. C-peptide status differentially affected metabolic responses in serum ACs during exercise (AC C18:1, leverage 0.066; squared prediction error 3.07). The malic acid/pyruvate ratio in rested serum was diagnostic for maximal aerobic capacity ( V ˙ O 2peak ) in people with type 1 diabetes (ROC curve AUC 0.867 [95% CI 0.716, 0.956]). CONCLUSIONS/INTERPRETATION: The serum metabolome distinguishes high and low maximal aerobic capacity and has diagnostic potential for facilitating personalised medicine approaches to manage aerobic exercise and fitness in type 1 diabetes.

来源:Diabetologia,查看原文。版权归原作者所有。

引用

  1. Taylor GS, Smith K, Scragg J, et al. The metabolome as a diagnostic for maximal aerobic capacity during exercise in type 1 diabetes. Diabetologia. 2024. PMID: 38662134. doi:10.1007/s00125-024-06153-0

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。