文献速递甲状腺疾病

改良美国放射学会甲状腺影像报告与数据系统与改良人工智能甲状腺影像报告与数据系统用于甲状腺结节:一项多中心回顾性研究

Modified American College of Radiology Thyroid Imaging Reporting and Data System and Modified Artificial Intelligence Thyroid Imaging Reporting and Data System for Thyroid Nodules: A Multicenter Retrospective Study.
PubMed 文献 · Thyroid · 2023-12-07

该多中心回顾性研究纳入6家中国医院2017年1月至2021年9月的2596个甲状腺结节(2511例患者),比较改良美国放射学会甲状腺影像报告与数据系统(ACR TI-RADS)与改良人工智能甲状腺影像报告与数据系统(AI TI-RADS)和原版ACR TI-RADS的诊断效能。结果显示,两种改良版均提高了特异度、准确率与曲线下面积并降低不必要细针穿刺率,敏感度略降但差异无统计学意义,且两种改良版之间诊断效能与不必要细针穿刺率无显著差异。

要点

  • 改良ACR TI-RADS将TR4细针穿刺阈值提高至2.5 cm,TR3不做细针穿刺。
  • 改良ACR TI-RADS特异度73% vs 原版46%,准确率74% vs 51%,不必要细针穿刺率25% vs 48%。
  • 改良AI TI-RADS与原版相比特异度73% vs 46%,不必要细针穿刺率24% vs 48%,两者诊断效能无显著差异。

核心结论

  • 改良后的细针穿刺阈值与分层标准可能提高特异度和准确率,而未显著牺牲恶性检出敏感度。

研究设计与样本

  • 多中心回顾性研究,纳入6家中国医院2017年1月至2021年9月超声检查且有明确病理诊断的2596个甲状腺结节(2511例患者)。

主要发现

  • 改良ACR TI-RADS较原版ACR TI-RADS特异度73% vs 46%、准确率74% vs 51%、曲线下面积0.80 vs 0.70均更高,不必要细针穿刺率25% vs 48%更低(均p < 0.001)。
  • 改良ACR TI-RADS较原版敏感度略降(87% vs 93%,p = 0.057)。
  • 改良AI TI-RADS较原版ACR TI-RADS特异度73% vs 46%、准确率75% vs 51%、曲线下面积0.81 vs 0.70均更高,不必要细针穿刺率24% vs 48%更低(均p < 0.001)。
  • 改良AI TI-RADS较原版敏感度略降(89% vs 93%,p = 0.13)。
  • 改良ACR TI-RADS与改良AI TI-RADS在诊断效能与不必要细针穿刺率上无显著差异(均p > 0.05)。

关键数值与推荐

  • 改良ACR TI-RADS标准:TR3不做细针穿刺;TR4细针穿刺阈值提高至2.5 cm。
  • 改良AI TI-RADS标准:6分结节升级为TR5;TR3不做细针穿刺;TR4细针穿刺阈值提高至2.5 cm。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

Background: Risk stratification systems for thyroid nodules are limited by low specificity. The fine-needle aspiration (FNA) biopsy size thresholds and stratification criteria are based on evidence from the literature and expert consensus. Our aims were to investigate the optimal FNA biopsy size thresholds in the American College of Radiology (ACR) Thyroid Imaging Reporting and Data System (TI-RADS) and artificial intelligence (AI) TI-RADS and to revise the stratification criteria in AI TI-RADS. Methods: A total of 2596 thyroid nodules (in 2511 patients) on ultrasound examination with definite pathological diagnoses were retrospectively identified from January 2017 to September 2021 in 6 participating Chinese hospitals. The modified criteria for ACR TI-RADS were as follows: (1) no FNA for TR3; (2) FNA threshold for TR4 increased to 2.5 cm. The modified criteria for AI TI-RADS were as follows: (1) 6-point nodules upgraded to TR5; (2) no FNA for TR3; (3) FNA threshold for TR4 increased to 2.5 cm. The diagnostic performance and the unnecessary FNA rate (UFR) of modified versions were compared with the original ACR TI-RADS. Results: Compared with the original ACR TI-RADS, the modified ACR (mACR) TI-RADS yielded higher specificity (73% vs. 46%), accuracy (74% vs. 51%), area under the receiver operating characteristic curve (AUC; 0.80 vs. 0.70), and lower UFR (25% vs. 48%; all p < 0.001), although the sensitivity was slightly decreased (87% vs. 93%, p = 0.057). Compared with the original ACR TI-RADS, the modified AI (mAI) TI-RADS yielded higher specificity (73% vs. 46%), accuracy (75% vs. 51%), AUC (0.81 vs. 0.70), and lower UFR (24% vs. 48%; all p < 0.001), although the sensitivity tended to be slightly decreased (89% vs. 93%, p = 0.13). There was no significant difference between the mACR TI-RADS and mAI TI-RADS in the diagnostic performance and UFR (all p > 0.05). Conclusions: The revised FNA thresholds and the stratification criteria of the mACR TI-RADS and mAI TI-RADS may be associated with improvements in specificity and accuracy, without significantly sacrificing sensitivity for malignancy detection.

来源:Thyroid,查看原文。版权归原作者所有。

引用

  1. Li X, Peng C, Liu Y, et al. Modified American College of Radiology Thyroid Imaging Reporting and Data System and Modified Artificial Intelligence Thyroid Imaging Reporting and Data System for Thyroid Nodules: A Multicenter Retrospective Study. Thyroid. 2023. PMID: 37950720. doi:10.1089/thy.2023.0429

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。