非典型及初诊漏诊甲状旁腺腺瘤的超声特征:单中心队列的经验教训
该研究评估445例生化证实的原发性甲状旁腺功能亢进症患者中457个甲状旁腺腺瘤的超声记录,发现49%的腺瘤至少有一种非典型超声特征,最常见为非典型大小(29%)和非典型回声(19%);初诊漏诊122个腺瘤,漏诊主因包括非典型大小(22.1%)、非典型位置(18.8%)和经验不足(16.3%)。
要点
- 近半数甲状旁腺腺瘤超声上至少有一种非典型特征。
- 非典型大小和非典型位置是初诊漏诊最常见的主因。
- 认识非典型超声特征或可提高超声检查准确性。
核心结论
- 近半数甲状旁腺腺瘤超声上至少有一种非典型特征,认识这些特征或可提高超声准确性并可能减少对更昂贵二线影像的需求。
研究设计与样本
- 单中心队列研究,评估445例生化证实的原发性甲状旁腺功能亢进症患者前瞻性维护数据库中的457个甲状旁腺腺瘤超声记录。
主要发现
- 研究组包括359例女性和86例男性原发性甲状旁腺功能亢进症患者。
- 231个腺瘤(51%)呈典型超声特征,226个(49%)至少有1种非典型超声特征。
- 最常见非典型特征为非典型大小(29%),其次为非典型回声(19%)、形状(8%)、位置(7%)和组成(7%)。
- 所有组中共有122个初诊漏诊的甲状旁腺腺瘤。
- 导致假阴性检查的最常见非典型超声主因为非典型大小(22.1%)和非典型位置(18.8%),经验不足为第三常见原因(16.3%)。
临床怎么用
- 作者认为,认识非典型超声特征的高 prevalence 或可提高超声检查准确性并可能减少对更昂贵二线影像的需求。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
CONTEXT: Awareness of typical and atypical ultrasonographic (US) features of parathyroid adenomas (PAs) is crucial since US is the most widely used first-line imaging modality. OBJECTIVE: The purpose of this study was to describe the atypical features of PAs on US and other possible factors leading to a false negative examination in a large single-center cohort. MATERIALS AND METHODS: The US records of 457 PAs in 445 patients with biochemically proven primary hyperparathyroidism (PHPT) were evaluated in a prospectively maintained database. Atypical size, composition, shape, echogenicity, location, and vascular pattern on US were noted. For patients who previously had at least one negative US examination in referring centers, the main possible reason was defined accordingly. RESULTS: The study group included 359 female and 86 male patients with PHPT. Typical sonographic features were observed in 231 PAs (51%), whereas 226 (49%) had at least one atypical US feature. The most common atypical features were atypical size (29%), followed by atypical echogenicity (19%), shape (8%), location (7%), and composition (7%), respectively. There were 122 initially missed PAs in all groups. The most frequent main atypical US features leading to false negative examinations were atypical size (22.1%) and atypical location (18.8%). Inexperience was third most common reason (16.3%) for false negative US examinations. CONCLUSIONS: Almost half of PAs have at least one atypical feature on US. Awareness of the high prevalence of atypical US features could increase the accuracy of US examination and potentially decrease demand for more expensive second-line imaging modalities.
引用
- Ilgan S, Aydoğan Bİ, Emer Ö, et al. Sonographic Features of Atypical and Initially Missed Parathyroid Adenomas: Lessons Learned From a Single-Center Cohort. J Clin Endocrinol Metab. 2024. PMID: 37668359. doi:10.1210/clinem/dgad527
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。