文献速递糖尿病

2型糖尿病患者连续血糖监测衍生的目标范围内时间与血糖变异系数与颈动脉壁组织特征改变相关

Continuous glucose monitoring-derived time in range and CV are associated with altered tissue characteristics of the carotid artery wall in people with type 2 diabetes.
PubMed 文献 · Diabetologia · 2023-09-26

这项前瞻性多中心观察性研究的探索性分析纳入600例无心血管症状史的2型糖尿病患者,在基线和104周时进行连续血糖监测(CGM)和颈动脉超声检查。校正包括HbA1c在内的动脉粥样硬化危险因素后,基线TIR和CV均与平均GSM及增厚病变GSM的年变化显著相关,达到国际共识CGM目标者的平均GSM年变化与未达标者存在显著差异。

要点

  • 基线TIR每增加10%,平均GSM年变化回归系数为0.52(95%CI 0.06, 0.98)。
  • 基线CV每增加1%,平均GSM年变化回归系数为-0.12(95%CI -0.22, -0.02)。
  • 达到基线CGM目标者的平均GSM年变化与未达标者存在显著差异(p=0.007)。

核心结论

  • TIR和CV与颈动脉壁组织特征的变化显著相关。

研究设计与样本

  • 一项正在进行的多中心前瞻性观察性研究的探索性分析,使用基线及104周数据。
  • 共600例无明确症状性心血管疾病史的2型糖尿病患者,在基线和104周接受CGM和颈动脉超声测量IMT与GSM。
  • 采用多变量回归模型分析CGM衍生指标(主要为TIR和CV)与颈动脉粥样硬化指标变化的相关性。

主要发现

  • 104周期间平均IMT从0.759±0.153 mm增至0.773±0.152 mm(p<0.001)。
  • 增厚病变GSM从43.5±19.5单位增至53.9±23.5单位(p<0.001)。
  • 颈总动脉最大IMT从1.109±0.442 mm至1.116±0.469 mm无显著变化(p=0.453),平均GSM从48.7±19.3至49.8±20.8单位无显著变化(p=0.092)。
  • 校正包括HbA1c在内的危险因素后,基线TIR每增加10%与平均GSM年变化回归系数0.52(95%CI 0.06, 0.98;Hochberg校正p值0.038)相关,基线CV每增加1%与平均GSM年变化回归系数-0.12(95%CI -0.22, -0.02;Hochberg校正p值0.038)相关。
  • 基线TIR每增加10%与增厚病变GSM年变化回归系数0.95(95%CI 0.12, 1.79;Hochberg校正p值0.038)相关,基线CV每增加1%与增厚病变GSM年变化回归系数-0.19(95%CI -0.36, -0.01;Hochberg校正p值0.038)相关。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

AIMS/HYPOTHESIS: Previous studies have suggested that glucose variability may accelerate atherosclerosis progression in people with type 2 diabetes. Current guidelines recommend assessing glycaemic control using continuous glucose monitoring (CGM), which provides a comprehensive glycaemic profile to supplement HbA1c measurement. However, the association between CGM-derived metrics and atherosclerosis progression is not entirely clear. METHODS: This exploratory study used baseline data and data obtained after 104 weeks from an ongoing prospective, multicentre, observational study. Six hundred study participants with type 2 diabetes and no apparent history of symptomatic cardiovascular disease underwent CGM and ultrasonographic atherosclerosis measurements of the carotid arteries, including the intima-media thickness (IMT) and grey-scale median (GSM), at baseline and 104 weeks. Non-invasive ultrasonic tissue characterisation of the carotid artery wall or plaque using the GSM reflects vascular composition. Multivariate regression models were used to analyse the association between CGM-derived indices, mainly time in range (TIR) and CV, and changes in carotid atherosclerosis index values. RESULTS: Over the 104-week study period, there were modest increases in mean IMT (from 0.759±0.153 to 0.773±0.152 mm, p<0.001) and thickened-lesion GSM (from 43.5±19.5 to 53.9±23.5 units, p<0.001), but no significant changes in common carotid artery maximum-IMT (from 1.109±0.442 to 1.116±0.469 mm, p=0.453) or mean GSM (from 48.7±19.3 to 49.8±20.8 units, p=0.092). In a linear regression model with adjustment for possible atherosclerotic risk factors, including HbA1c, TIR and CV at baseline were significantly associated with the annual change in mean GSM (regression coefficient per 10% increase in TIR 0.52; 95% CI 0.06, 0.98; Hochberg-adjusted p value 0.038; regression coefficient per 1% increase in CV -0.12; 95% CI -0.22, -0.02; Hochberg-adjusted p value 0.038). TIR and CV at baseline were also significantly associated with the annual change in thickened-lesion GSM (regression coefficient per 10% increase in TIR 0.95; 95% CI 0.12, 1.79; Hochberg-adjusted p value 0.038; regression coefficient per 1% increase in CV -0.19; 95% CI -0.36, -0.01; Hochberg-adjusted p value 0.038). Participants who achieved target CGM-derived metrics at baseline, as proposed by an international consensus, showed significant annual changes in mean GSM compared with those who did not (0.94±6.88 vs -0.21±6.19 units/year, p=0.007). CONCLUSIONS/INTERPRETATION: TIR and CV were significantly associated with changes in the tissue characteristics of the carotid artery wall. TRIAL REGISTRATION: University Hospital Medical Information Network Clinical Trials Registry, number UMIN000032325.

来源:Diabetologia,查看原文。版权归原作者所有。

引用

  1. Mita T, Katakami N, Okada Y, et al. Continuous glucose monitoring-derived time in range and CV are associated with altered tissue characteristics of the carotid artery wall in people with type 2 diabetes. Diabetologia. 2023. PMID: 37750893. doi:10.1007/s00125-023-06013-3

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。