比较自动胰岛素输注(人工胰腺)联合碳水化合物计数或简化定性餐量估算在1型糖尿病中的随机交叉试验
两中心随机交叉非劣效试验比较成人1型糖尿病自动胰岛素输注联合碳水化合物计数或定性餐量估算各3周。主要结局3.9-10.0 mmol/L时间范围:计数组74.1% vs 定性组70.5%,平均差-3.6%(非劣效P=0.78),非劣效未确认。定性组基础胰岛素输注量更高(34.6 vs 32.6 U/d,P=0.003)。
要点
- 定性餐量估算组3.9-10.0 mmol/L时间范围70.5%,低于计数组的74.1%,非劣效未确认。
- 两组低血糖时间均低(<3.9 mmol/L <1.6%,<3.0 mmol/L <0.2%)。
- 定性组自动基础胰岛素输注量高于计数组(34.6 vs 32.6 U/d,P=0.003)。
核心结论
- 定性餐量估算策略虽实现高时间范围和低低血糖时间,但非劣效性未确认。
研究设计与样本
- 两中心、随机、交叉、非劣效试验,比较成人1型糖尿病自动胰岛素输注联合碳水化合物计数或定性餐量估算各3周。
- 30例参与者完成研究(女性20例;年龄44(SD 17)岁;A1C 7.4%[0.7%])。
- 定性餐量估算分为低、中、高、极高碳水化合物四类,分别定义为<30 g、30-60 g、60-90 g和>90 g碳水化合物。
- 餐时胰岛素大剂量按个体化胰岛素与碳水化合物比值分别乘以15、35、65和95计算。
- 两臂闭环算法其他方面相同;主要结局为3.9-10.0 mmol/L时间范围,预设非劣效界值4%。
主要发现
- 3.9-10.0 mmol/L平均时间范围:碳水化合物计数组74.1%(10.0%) vs 定性餐量估算组70.5%(11.2%);平均差-3.6%(8.3%;非劣效P=0.78)。
- 两组<3.9 mmol/L和<3.0 mmol/L时间频率均低(分别<1.6%和<0.2%)。
- 自动基础胰岛素输注量定性餐量估算组高于碳水化合物计数组(34.6 vs 32.6 U/d;P=0.003)。
关键数值与推荐
- 定性餐量估算分类阈值:低<30 g、中30-60 g、高60-90 g、极高>90 g碳水化合物。
- 餐时胰岛素大剂量计算:个体化胰岛素与碳水化合物比值分别乘以15、35、65和95。
- 非劣效界值预设为4%。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: Qualitative meal-size estimation has been proposed instead of quantitative carbohydrate (CHO) counting with automated insulin delivery. We aimed to assess the noninferiority of qualitative meal-size estimation strategy. RESEARCH DESIGN AND METHODS: We conducted a two-center, randomized, crossover, noninferiority trial to compare 3 weeks of automated insulin delivery with 1) CHO counting and 2) qualitative meal-size estimation in adults with type 1 diabetes. Qualitative meal-size estimation categories were low, medium, high, or very high CHO and were defined as <30 g, 30-60 g, 60-90 g, and >90 g CHO, respectively. Prandial insulin boluses were calculated as the individualized insulin to CHO ratios multiplied by 15, 35, 65, and 95, respectively. Closed-loop algorithms were otherwise identical in the two arms. The primary outcome was time in range 3.9-10.0 mmol/L, with a predefined noninferiority margin of 4%. RESULTS: A total of 30 participants completed the study (n = 20 women; age 44 (SD 17) years; A1C 7.4% [0.7%]). The mean time in the 3.9-10.0 mmol/L range was 74.1% (10.0%) with CHO counting and 70.5% (11.2%) with qualitative meal-size estimation; mean difference was -3.6% (8.3%; noninferiority P = 0.78). Frequencies of times at <3.9 mmol/L and <3.0 mmol/L were low (<1.6% and <0.2%) in both arms. Automated basal insulin delivery was higher in the qualitative meal-size estimation arm (34.6 vs. 32.6 units/day; P = 0.003). CONCLUSIONS: Though the qualitative meal-size estimation method achieved a high time in range and low time in hypoglycemia, noninferiority was not confirmed.
引用
- Haidar A, Legault L, Raffray M, et al. A Randomized Crossover Trial to Compare Automated Insulin Delivery (the Artificial Pancreas) With Carbohydrate Counting or Simplified Qualitative Meal-Size Estimation in Type 1 Diabetes. Diabetes Care. 2023. PMID: 37134305. doi:10.2337/dc22-2297
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。