研究纳入109例乌得勒支大学医学中心门诊患者,比较静脉血浆与指血干血斑(DBS)促甲状腺素(TSH)在自动化高通量免疫分析仪上的检测表现。静脉血浆与指血DBS的TSH方法学比较R²为0.988(95%CI 0.986-0.990),正确诊断14例中12例低促甲状腺素血症和7例中6例甲状腺功能减退症,无误诊。DBS中TSH在-20°C至+30°C下至少稳定4天;血细胞比容每升高1%,洗脱液TSH最大下降1.13%。作者认为DBS-TSH经更大规模现场研究确认后,可能用于远程诊断、筛查、随访和药物管理。

要点

  • 静脉血浆与指血DBS的TSH方法学比较R²为0.988(95%CI 0.986-0.990)。
  • DBS-TSH正确诊断低促甲状腺素血症14例中12例、甲状腺功能减退症7例中6例,无误诊。
  • DBS中TSH在-20°C至+30°C下至少稳定4天。

核心结论

  • DBS中的TSH可在自动化高通量免疫分析仪上准确检测,并可能用于诊断甲状腺功能减退症和首次用于诊断低促甲状腺素血症。
  • 该方法经更大规模现场研究确认后,可能使个体通过DBS进行居家采血,用于远程诊断、筛查项目、患者随访和药物管理。

研究设计与样本

  • 研究纳入109例就诊于乌得勒支大学医学中心门诊的患者,采用毛细血管指血采集并滴于滤纸卡上干燥制成DBS。
  • 从DBS中提取TSH后,在自动化高通量免疫分析仪上与静脉TSH进行方法学比较,并按临床与实验室标准协会相应评估方案进行稳定性、血细胞比容影响、精密度及空白限和定量限的验证。

主要发现

  • 静脉血浆与指血DBS的TSH方法学比较R²为0.988(95%CI 0.986-0.990)。
  • DBS-TSH正确诊断低促甲状腺素血症14例中12例、甲状腺功能减退症7例中6例,无误诊。
  • DBS中TSH在-20°C至+30°C下至少稳定4天。
  • 血细胞比容每升高1%,洗脱液TSH最大下降1.13%。

关键数值与推荐

  • 静脉血浆与指血DBS的TSH方法学比较R²为0.988(95%CI 0.986-0.990)。
  • DBS-TSH正确诊断低促甲状腺素血症14例中12例、甲状腺功能减退症7例中6例,无误诊。
  • DBS中TSH在-20°C至+30°C下至少稳定4天。
  • 血细胞比容每升高1%,洗脱液TSH最大下降1.13%。

临床怎么用

  • 作者认为DBS-TSH经更大规模现场研究确认后,可能使个体通过DBS进行居家采血,用于远程诊断、筛查项目、患者随访和药物管理。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

Background: Hyper- and hypothyroidism are prevalent in Western countries and often go unnoticed for long periods. Thyrotropin (TSH) as a biomarker of thyroid dysfunction is regularly measured in venous plasma/serum. In newborn screening for congenital hypothyroidism, TSH is measured from dried blood spots (DBSs). DBS enables minimally invasive (at-home) sampling of a small blood volume that can be sent to diagnostic laboratories by regular mail. Methods: In this study, we included 109 patients who presented to the outpatient clinic of the University Medical Center Utrecht. Capillary finger stick was used to spot blood on a filter paper card and was dried. After extraction of TSH from DBS, method comparison with venous TSH was performed on an automated high-throughput immunoassay analyzer. Additional validation steps regarding stability, effect of hematocrit (Hct), precision, and limits of blank and quantitation were conducted according to corresponding Clinical and Laboratory Standards Institute evaluation protocol. Results: Method comparison of TSH from venous plasma versus finger stick DBSs showed an R2 [95% confidence interval] = 0.988 [0.986-0.990]. This enabled correct diagnosis of hypothyrotropinemia and hypothyroidism in 12 of 14 and 6 of 7 cases, respectively, with no false positives. Furthermore, TSH from DBS was stable for at least 4 days at temperatures between -20°C and +30°C, and the maximum decrease of eluate TSH was 1.13% for 1% increase in Hct. Conclusions: TSH from DBS may be accurately measured on an automated high-throughput immunoassay analyzer and could be used to diagnose hypothyroidism and, for the first time, hypothyrotropinemia. This method, when confirmed in larger field studies, may enable individuals to engage in (at-home) sampling of blood on DBSs for telediagnostics, screening programs, patient follow-up, and medication management.