一句话结论在院外心脏骤停成人中,使用Real BVM Help®实时反馈与AHA通气指南达标率显著提高相关,作者认为治疗心脏骤停时应考虑通气压与潮气量的实时监测反馈。

该前瞻性前后对照质量保证研究在威斯康星州密尔沃基县急救医疗服务与基诺沙消防部门开展,纳入278例成人院外心脏骤停患者(Before组148例、After组130例)。Before组使用呼气末二氧化碳(ETCO2)监测通气并应用盲法Real BVM Help®,After组使用非盲法Real BVM Help®。主要终点为每人通气中速率、潮气量及两者同时达标的比例,After组三项均显著高于Before组。作者结论认为Real BVM Help®与AHA通气指南依从性改善相关,仅用ETCO2监测难以兼顾速率与潮气量达标,作者建议治疗心脏骤停时考虑通气压与潮气量的实时反馈监测。

要点

  • After组每人通气同时满足速率与潮气量达标的比例为39.0±23.3%,Before组为7.5±9.6%(p<0.0001)。
  • After组速率达标比例74.4±24.1% vs Before组47.7±25.1%(p<0.0001),潮气量达标比例45.4±23.8% vs 15.3±15.4%(p<0.0001)。
  • Before组仅用ETCO2监测全部22037次通气时,速率达标43.8%、潮气量达标13.5%、两者同时达标6.8%,潮气量低于目标占58.2%。
  • After组使用非盲法Real BVM Help®,与AHA 2020通气指南速率与潮气量达标率的显著改善相关。
  • 作者认为治疗心脏骤停时应考虑通气压与潮气量的实时反馈监测。

适用人群与场景

  • 成人院外心脏骤停患者,由威斯康星州密尔沃基县急救医疗服务与基诺沙消防部门救治。

诊断标准与关键阈值

  • 通气达标判定依据AHA 2020指南,主要终点为每人通气中速率、潮气量及两者同时达标的平均比例(%)。

处置流程与药物剂量

  • Before组:使用呼气末二氧化碳(ETCO2)监测通气,应用Real BVM Help®但设盲。
  • After组:使用非盲法Real BVM Help®进行通气实时反馈监测。
  • 作者认为治疗心脏骤停时应考虑通气压与潮气量的实时反馈监测。

研究设计与关键结果

  • 前瞻性前后对照质量保证研究,纳入278例成人院外心脏骤停患者(Before组148例、After组130例),比较ETCO2监测联合盲法Real BVM Help®(Before)与非盲法Real BVM Help®(After)的通气达标情况。
  • 速率达标比例:After组74.4±24.1% vs Before组47.7±25.1%(p<0.0001);潮气量达标比例:After组45.4±23.8% vs Before组15.3±15.4%(p<0.0001);速率与潮气量同时达标比例:After组39.0±23.3% vs Before组7.5±9.6%(p<0.0001)。
  • Before组使用ETCO2监测全部22037次通气中,速率达标43.8%、潮气量达标13.5%、两者同时达标6.8%,潮气量低于目标占全部通气的58.2%。

证据类型、等级与局限

  • 证据类型:前瞻性前后对照质量保证研究。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 在成人院外心脏骤停救治中,仅用ETCO2监测通气时速率与潮气量同时达标比例低(Before组22037次通气中仅6.8%同时达标),潮气量低于目标最常见(58.2%)。
  • 作者认为Real BVM Help®与AHA通气指南依从性改善相关,治疗心脏骤停时应考虑通气压与潮气量的实时反馈监测。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
  • 另有 1 条提炼内容因数值无法与原文逐一核对而未列出,请以原文为准。
英文原文(摘要)· 点击展开

INTRODUCTION: Adherence to American Heart Association (AHA) ventilation guidelines during cardiac arrest is challenging.

METHODS: Prospective, Before/After quality assurance study determining adherence to AHA ventilation guidelines in adults with out-of-hospital cardiac arrest treated by Milwaukee County Emergency Medical Services and Kenosha Fire in Wisconsin using (Before) end tidal carbon dioxide [ETCO2] to monitor ventilations - Real BVM Help® applied but blinded versus (After) Real BVM Help®.

PRIMARY ENDPOINTS: mean per-person proportion (%) of ventilations in-target for rate, tidal volume, and both rate and tidal volume. AHA 2020 guidelines were followed.

RESULTS: From 9/29/22-12/22/23, 278 patients were entered (148 Before/130 After). Average age: 62.3 ± 16.7 years; 185 (67%) male. Mean per-person proportion (%) of ventilations in Before/After Groups in-target for rate (47.7 ± 25.1% vs 74.4 ± 24.1% respectively, p < 0.0001), tidal volume (15.3 ± 15.4% vs 45.4 ± 23.8% respectively, p < 0.0001), and rate and tidal volume (7.5 ± 9.6% vs 39.0 ± 23.3% respectively, p < 0.0001) were significantly higher in the After Group. In the Before Group, using ETCO2 to monitor all ventilations (N = 22,037 ventilations), only 43.8% were in-target for rate, 13.5% in-target for tidal volume, and 6.8% in-target for rate and tidal volume with a lower-than-target tidal volume delivered in 58.2% of all ventilations.

CONCLUSION: Real BVM Help® was associated with statistically significant and clinically meaningful improvement in adherence to AHA ventilation guidelines. ETCO2 monitoring failed to approach both rate and tidal volume guideline adherence with a lower-than-target tidal volume being the most common parameter delivered out-of-target (58.2%). Ventilation rate and tidal volume monitoring with real-time feedback should be considered during treatment of cardiac arrest.