重症监护各领域报警疲劳:一项横断面多中心调查的比较见解与独立预测因素
该研究为横断面多中心调查,纳入514名在ICU、心脏遥测病房(CTW)和手术室(OR)工作的医护人员,使用荷兰语版Charité报警疲劳问卷(含报警压力和报警应对两个子量表)评估报警疲劳,并让参与者用1-10分自评报警疲劳及感知的误报警百分比。结果显示,遥测病房工作人员的自评报警疲劳最高(B=0.65;95%CI 0.06-1.24;p=0.032),感知误报警也最高(B=0.77;95%CI 0.23-1.30;p=0.005);手术室工作人员最低(B=-1.01;95%CI -1.59至-0.43;p<0.001)。医师(B=-0.13;95%CI -0.25至-0.01;p<0.031)和工龄不足3个月者(B=-0.34;95%CI -0.68至-0.01;p=0.046)报告的报警疲劳较低。作者认为需要针对科室的干预和纵向研究来减轻报警疲劳并提升患者安全。
要点
- 遥测病房工作人员自评报警疲劳最高(B=0.65;95%CI 0.06-1.24;p=0.032),感知误报警也最高(B=0.77;95%CI 0.23-1.30;p=0.005)。
- 手术室工作人员自评报警疲劳最低(B=-1.01;95%CI -1.59至-0.43;p<0.001)。
- 医师报告的报警疲劳低于其他职业(B=-0.13;95%CI -0.25至-0.01;p<0.031)。
- 工龄不足3个月的工作人员报告的报警疲劳较低(B=-0.34;95%CI -0.68至-0.01;p=0.046)。
- 作者认为需要针对科室的干预和纵向研究来减轻报警疲劳并提升患者安全。
适用人群与场景
- 在ICU、心脏遥测病房(CTW)和手术室(OR)工作的医护人员,共514名。
研究设计与关键结果
- 研究类型:横断面多中心调查,样本量514名医护人员,涉及ICU、心脏遥测病房(CTW)和手术室(OR)。
- 主要终点:遥测病房工作人员自评报警疲劳最高(B=0.65;95%CI 0.06-1.24;p=0.032),感知误报警最高(B=0.77;95%CI 0.23-1.30;p=0.005);手术室工作人员最低(B=-1.01;95%CI -1.59至-0.43;p<0.001)。
- 关键次要终点:医师报警疲劳较低(B=-0.13;95%CI -0.25至-0.01;p<0.031);工龄不足3个月者较低(B=-0.34;95%CI -0.68至-0.01;p=0.046)。
证据类型、等级与局限
- 证据类型:横断面多中心调查。
- 局限:原文未报告局限性。
对床旁实践的改变
- 作者认为需要针对科室的干预和纵向研究来减轻报警疲劳并提升患者安全。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
OBJECTIVES: Alarm fatigue, the desensitization to excessive false alarms, threatens patient safety and staff performance across critical care domains. It is unclear whether alarm fatigue differs between hospital departments. This study compared alarm fatigue among staff in the ICU, cardiac telemetry ward (CTW), and operating room (OR), and, secondarily, identified its independent determinants.
DESIGN: Cross-sectional, multicenter survey study.
SETTING: ICUs, a CTW, and ORs.
PATIENTS: A total of 514 healthcare professionals working in the ICU, CTW, and OR.
INTERVENTIONS: None.
MEASUREMENTS AND MAIN RESULTS: Alarm fatigue was assessed using the Dutch-translated Charité Alarm Fatigue Questionnaire, which includes alarm stress and alarm coping subscales. Participants also rated their self-perceived alarm fatigue on a 1-10 scale and the percentage of perceived false alarms. Telemetry staff reported the highest self-perceived alarm fatigue (B = 0.65; 95% CI, 0.06-1.24; p = 0.032) and perceived false alarms (B = 0.77; 95% CI, 0.23-1.30; p = 0.005), while OR staff reported the lowest (B = -1.01; 95% CI, -1.59 to -0.43; p < 0.001). Second, physicians (B = -0.13; 95% CI, -0.25 to -0.01; p < 0.031) and less experienced staff (< 3 mo; B = -0.34; 95% CI, -0.68 to -0.01; p = 0.046) reported lower alarm fatigue.
CONCLUSIONS: Alarm fatigue varied significantly across departments and professions, being highest in telemetry staff and lowest among physicians and less experienced personnel. Targeted department-specific interventions and longitudinal research are necessary to mitigate alarm fatigue and enhance patient safety.
参考来源
- Le Pera T, Gerardu VCA, van Bussel BCT, et al. Alarm Fatigue Across Critical Care Domains: Comparative Insights and Independent Predictors From a Cross-Sectional Multicenter Survey Study. Crit Care Med. 2026. PMID: 43012575. doi:10.1097/CCM.0000000000007416
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。