文献速递复苏、休克与脓毒症重症综合管理与镇静镇痛

双平面成像与标准横切单平面成像在超声引导外周静脉置管中的比较:一项前瞻性对照交叉试验

Biplane Imaging Versus Standard Transverse Single-Plane Imaging for Ultrasound-Guided Peripheral Intravenous Access: A Prospective Controlled Crossover Trial.
PubMed 文献 · Crit Care Explor · 2021-10-08
一句话结论对无超声经验的外科ICU护士,体模上双平面成像较单平面横切提高外周静脉置管成功率、首针成功率并减少后壁穿透。

双平面组总体成功率78.3%±22.4% vs 41.7%±26%(p<0.001),首针成功率80%±41% vs 45%±51%(p=0.015),置管时间27.8±14.8 vs 36.6±15.8 s(p=0.003),后壁穿透次数0.4±0.7 vs 1.5±0.8(p<0.001)。结论为原理验证性研究,提示新手使用双平面成像可更快、更成功、更安全地完成外周静脉置管。

要点

  • 对无超声经验的外科ICU护士,体模上双平面成像总体置管成功率78.3%±22.4%,高于单平面横切的41.7%±26%(p<0.001)。
  • 双平面成像首针成功率80%±41%,高于单平面横切的45%±51%(p=0.015)。
  • 双平面成像置管时间27.8±14.8 s,短于单平面横切的36.6±15.8 s(p=0.003)。
  • 双平面成像后壁穿透次数0.4±0.7,少于单平面横切的1.5±0.8(p<0.001)。

适用人群与场景

  • 原文未提及患者纳入/排除标准及临床适用人群。

诊断标准与关键阈值

  • 原文未提及

处置流程与药物剂量

  • 第一步:所有参与者观看单平面与双平面成像用于外周静脉置管的教学视频。
  • 第二步:准随机(交替分配)决定先用单平面或双平面成像,在体模上完成3次置管尝试。
  • 第三步:记录每次尝试的置管完成时间、管腔置入成功与否、以及针尖穿透血管后壁的次数。
  • 第四步:次日参与者改用另一种成像方式重复外周静脉置管操作。

红旗征与不能漏的情况

  • 原文未提及

研究设计与关键结果

  • 干预与对照:双平面成像 vs 标准横切单平面成像,每位参与者两种方式各完成3次尝试。
  • 主要结局:双平面总体成功率78.3%±22.4% vs 单平面41.7%±26%(p<0.001)。
  • 关键次要结局:首针成功率80%±41% vs 45%±51%(p=0.015);置管时间27.8±14.8 vs 36.6±15.8 s(p=0.003);后壁穿透次数0.4±0.7 vs 1.5±0.8(p<0.001)。
  • 不良事件:原文未提及除后壁穿透外的其他不良事件。

证据类型、等级与局限

  • 证据类型:前瞻性准随机(交替分配)交叉试验,属原理验证性研究。

对床旁实践的改变

  • 对无超声引导外周静脉置管经验的新手,在体模训练中采用双平面成像可能提高置管成功率、首针成功率并减少后壁穿透。
  • 该证据来自体模与新手护士,不能直接改变急诊/ICU真实患者的外周静脉置管常规或作为临床推荐。
  • 原文未提及适用与不适用人群的排除标准,临床推广需谨慎。

指南或共识出处

  • 原文未提及

以上提炼依据论文摘要(全文未开放获取,或许可不允许翻译转载);全文请点「阅读原文」。

英文原文(摘要)· 点击展开

UNLABELLED: Obtaining peripheral IV access in critically ill patients is often challenging especially for novice providers. The availability of biplane imaging for ultrasound guided peripheral access has the potential to improve successful venous cannulation compared with standard plane imaging.

DESIGN: Single-center quasi-randomized (alternate allocation) crossover trial.

SETTING: Surgical ICU at the Massachusetts General Hospital.

SUBJECTS: Twenty surgical ICU nurses with no prior experience using ultrasound for peripheral IV were enrolled.

INTERVENTIONS: All participants viewed instructional videos on single-plane and biplane imaging for peripheral IV insertion. The participants were then quasi-randomly assigned to use either single-plane or biplane imaging for peripheral IV insertion using a phantom model. The time to catheter completion, successful lumen cannulation, and attempts in which the needle was observed to go through the back wall of the vessel were recorded for each of the three attempts. The following day the participants repeated the peripheral IV insertion with the alternate imaging modality.

MEASUREMENTS AND MAIN RESULTS: Biplane imaging compared with single-plane imaging was associated with a significantly greater overall success rate (78.3% ± 22.4% vs 41.7% ± 26%; p < 0.001), higher first-pass success rate (80% ± 41% vs 45% ± 51%; p = 0.015), faster cannulation times (27.8 ± 14.8 vs 36.6 ± 15.8 s; p = 0.003), and reduced frequency of backwall perforations (0.4 ± 0.7 vs 1.5 ± 0.8; p < 0.001).

CONCLUSIONS: This proof-of-principle study demonstrates that the biplane ultrasound imaging approach for vessel cannulation resulted in an overall faster, more successful, and safer peripheral IV access than the standard single-plane transverse approach when performed by novice ultrasound users.

来源:Crit Care Explor,查看原文。版权归原作者所有。

参考来源

  1. Convissar D, Bittner EA, Chang MG, et al. Biplane Imaging Versus Standard Transverse Single-Plane Imaging for Ultrasound-Guided Peripheral Intravenous Access: A Prospective Controlled Crossover Trial. Crit Care Explor. 2021. PMID: 34651134. doi:10.1097/CCE.0000000000000545

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。