文献速递儿科与产科急症

儿童尿路感染:一种新型非侵入性即时诊断标志物的探索

Urinary tract infections in children: Testing a novel, noninvasive, point-of-care diagnostic marker.
PubMed 文献 · Acad Emerg Med · 2021-11-09
一句话结论袋装尿与导尿标本uNGAL一致性不足,不能互换;袋装尿uNGAL特异性低(73.8%),采样技术影响uNGAL水平。

本研究为前瞻性研究,纳入211例<24月龄发热儿童(10%尿培养阳性),其中116对有导尿与袋装尿配对标本。主要目的是确定配对导尿与袋装尿标本uNGAL水平的一致性,次要目的是比较定量uNGAL、试纸uNGAL和尿常规的诊断特性。结果:定量uNGAL(≥39.1 ng/mL)一致性为0.76(95%CI 0.67-0.83),试纸uNGAL(>50 ng/mL)一致性为0.77(95%CI 0.68-0.84);导尿标本uNGAL的AUC为0.96(95%CI 0.89-1.00),袋装尿为0.93(95%CI 0.87-0.99);导尿标本定量与试纸uNGAL敏感性均为90.5%,高于尿常规LE≥1+的57.1%;袋装尿uNGAL定量与试纸特异性均为73.8%,低于导尿标本(94.3%和95.3%)。结论:袋装与导尿标本uNGAL一致性不足,不能互换使用;袋装尿uNGAL低特异性提示采样技术影响uNGAL水平。

要点

  • 在<24月龄发热儿童中,袋装尿与导尿标本uNGAL一致性不足(定量κ=0.76,试纸κ=0.77),不能互换使用。
  • 导尿标本uNGAL诊断UTI的AUC为0.96(95%CI 0.89-1.00),袋装尿为0.93(95%CI 0.87-0.99)。
  • 导尿标本定量与试纸uNGAL敏感性均为90.5%,高于尿常规LE≥1+的57.1%。
  • 袋装尿uNGAL定量与试纸特异性均为73.8%,低于导尿标本(94.3%和95.3%),与尿常规相似。
  • 采样技术影响uNGAL水平,袋装尿标本uNGAL特异性低,解读结果时需考虑采样方式。

适用人群与场景

  • 适用于<24月龄因发热评估尿路感染的儿童,场景为急诊或门诊评估。
  • 排除人群原文未提及。

诊断标准与关键阈值

  • 尿培养阳性定义为>100,000 CFUs/mL的病原体。
  • 定量uNGAL阈值采用先前确定的39.1 ng/mL。
  • 试纸uNGAL阈值采用内置的>50 ng/mL。
  • 尿常规白细胞酯酶(LE)采用标准阈值。

处置流程与药物剂量

  • 原文未提及

红旗征与不能漏的情况

  • 原文未提及

研究设计与关键结果

  • 前瞻性研究,纳入211例<24月龄发热儿童(10%尿培养阳性),其中116对有导尿与袋装尿配对标本。
  • 导尿与袋装标本定量uNGAL(≥39.1 ng/mL)一致性为0.76(95%CI 0.67-0.83),试纸uNGAL(>50 ng/mL)一致性为0.77(95%CI 0.68-0.84)。
  • 导尿标本uNGAL的AUC为0.96(95%CI 0.89-1.00),袋装尿为0.93(95%CI 0.87-0.99)。
  • 导尿标本定量与试纸uNGAL敏感性均为90.5%,高于尿常规LE≥1+的57.1%。
  • 袋装尿uNGAL定量与试纸特异性均为73.8%,低于导尿标本(94.3%和95.3%),与尿常规相似。

证据类型、等级与局限

  • 证据类型:前瞻性诊断准确性研究。
  • 局限:单中心、样本量较小(211例),尿培养阳性率低(10%),袋装尿标本可能受污染影响。

对床旁实践的改变

  • 袋装尿与导尿标本uNGAL不可互换,解读袋装尿uNGAL结果时需注意其较低特异性(73.8%)。
  • 导尿标本uNGAL敏感性高(90.5%),但袋装尿uNGAL特异性低,可能影响临床决策。
  • 采样技术影响uNGAL水平,临床应规范采样方式。

指南或共识出处

  • 原文未提及

以上提炼依据论文摘要(全文未开放获取,或许可不允许翻译转载);全文请点「阅读原文」。

英文原文(摘要)· 点击展开

OBJECTIVES: Urinary neutrophil gelatinase-associated lipocalin (uNGAL) appears highly accurate to identify urinary tract infections (UTIs) when obtained via catheterization. Our primary aim was to determine the agreement in uNGAL levels between paired catheter and bag urine specimens. Our secondary aim was to compare the diagnostic test characteristics of quantitative uNGAL, dipstick uNGAL (a potential point-of-care test), and urinalysis (UA).

METHODS: This was a prospective study of febrile children < 24 months evaluated for UTIs. We evaluated quantitative uNGAL at a previously identified threshold of 39.1 ng/mL, dipstick uNGAL at its built-in threshold of >50 ng/mL, and UA at standard thresholds for leukocyte esterase (LE). A positive urine culture was defined as >100,000 CFUs/mL of a pathogen.

RESULTS: A total of 211 patients were included (10% with positive urine cultures); 116 had paired catheterized and bagged samples. The agreement between catheterized and bagged samples at a quantitative uNGAL cutoff of ≥39.1 ng/mL was 0.76 (95% confidence interval [CI] = 0.67 to 0.83) and 0.77 (95% CI = 0.68 to 0.84) at a uNGAL dipstick threshold of >50 ng/mL. The area under the receiver operating characteristic curve for uNGAL from a catheterized sample was 0.96 (95% CI = 0.89 to 1.00) compared to 0.93 (95% CI = 0.87 to -0.99) from a bagged sample. The sensitivities of catheterized sample quantitative and dipstick uNGAL (90.5%) were higher than UA at a LE threshold of ≥1+ (57.1%). Bagged-sample uNGAL had lower quantitative and dipstick specificities (both 73.8%) than from catheterized samples (94.3% and 95.3% respectively), similar to UA.

CONCLUSIONS: uNGAL from bagged and catheterized samples showed insufficient agreement to be used interchangeably. The low specificity of uNGAL from bagged samples suggests that sampling technique affects uNGAL levels.

来源:Acad Emerg Med,查看原文。版权归原作者所有。

参考来源

  1. Lubell TR, Barasch JM, King B, et al. Urinary tract infections in children: Testing a novel, noninvasive, point-of-care diagnostic marker. Acad Emerg Med. 2021. PMID: 34665891. doi:10.1111/acem.14402

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。