syndecan-1联合肺超声评估急性呼吸窘迫综合征患者血管外肺水
单中心纳入50例ARDS患者,均置入PiCCO导管监测EVLWI和PVPI,同时行肺超声计算双肺10个切面B线总数并检测血浆SDC-1。B线数与EVLWI、PVPI显著正相关(r=0.802、0.799),SDC-1亦与EVLWI、PVPI正相关(r=0.732、0.576)。以EVLWI 10 mL/kg为界划分轻/重度肺水肿,B线数AUC 0.891、SDC-1 AUC 0.875,两者联合AUC 0.958,敏感度92.9%、特异度91.8%。提示两者联合可作为无创评估ARDS血管外肺水程度的指标。
要点
- ARDS患者B线数与EVLWI显著正相关(r=0.802,P<0.01),B线数截断值40.50时预测重度肺水肿敏感度82.1%、特异度86.4%。
- 血浆SDC-1与EVLWI正相关(r=0.732,P<0.01),截断值559.37 μg/L时敏感度85.7%、特异度81.8%。
- B线数联合SDC-1预测肺水肿严重程度AUC 0.958(95%CI 0.890-1.000),优于单一指标。
- 研究以EVLWI 10 mL/kg为界划分轻度与重度肺水肿,联合指标可用于无创评估血管外肺水程度。
- 研究为单中心50例,联合指标的临床决策价值尚需前瞻性验证。
适用人群与场景
- 2018年7月至2019年7月南京医科大学附属无锡市人民医院ICU收治的50例ARDS患者。
- 入组患者CI为(46.84±6.00)mL×s-1×m-2、CVP为(8.12±1.80)mmHg,已排除心源性肺水肿。
诊断标准与关键阈值
- 以EVLWI 10 mL/kg为边界值,将ARDS患者肺水肿程度分为轻度肺水肿与重度肺水肿。
- B线数预测重度肺水肿的截断值为40.50,SDC-1截断值为559.37 μg/L。
- B线计数方法:双肺上蓝点、下蓝点、膈肌点、Plaps点、后蓝点共10个超声切面下B线数目之和。
处置流程与药物剂量
- 第一步:所有患者入ICU后置入PiCCO导管,由一名医生监测EVLWI和PVPI。
- 第二步:由另一名医生行肺超声检查,计算双肺10个切面B线数之和。
- 第三步:采用酶联免疫吸附试验(ELISA)检测血浆SDC-1水平。
- 第四步:将B线数与SDC-1联合用于评估ARDS患者血管外肺水程度。
红旗征与不能漏的情况
- 原文未提及
研究设计与关键结果
- 研究类型:单中心观察性研究,纳入50例ARDS患者。
- 50例患者EVLWI为(10.82±2.92)mL/kg,PVPI为3.02±0.69,B线数为40.90±13.05,血浆SDC-1为(568.25±118.14)μg/L。
- B线数与EVLWI、PVPI正相关(r1=0.802,r2=0.799,均P<0.01);SDC-1与EVLWI、PVPI正相关(r1=0.732,r2=0.576,均P<0.01)。
- B线数预测肺水肿严重程度AUC 0.891(95%CI 0.803-0.979),截断值40.50时敏感度82.1%、特异度86.4%。
- SDC-1预测肺水肿严重程度AUC 0.875(95%CI 0.772-0.978),截断值559.37 μg/L时敏感度85.7%、特异度81.8%。
- B线数联合SDC-1的AUC 0.958(95%CI 0.890-1.000),敏感度92.9%、特异度91.8%。
证据类型、等级与局限
- 证据类型:单中心观察性研究。
- 局限:样本量小(50例)、单中心、观察性设计,联合指标的预测价值需前瞻性验证。
对床旁实践的改变
- 在已置入PiCCO的ARDS患者中,可用肺超声B线数与血浆SDC-1联合无创评估血管外肺水程度,减少对PiCCO的单一依赖。
- B线数或SDC-1单独升高提示肺水肿可能较重,但联合两项指标预测价值更高(AUC 0.958)。
- 该研究为单中心小样本,截断值不宜直接作为临床决策阈值,需结合临床综合判断。
指南或共识出处
- 原文未提及
以上提炼依据论文摘要(全文未开放获取,或许可不允许翻译转载);全文请点「阅读原文」。
英文原文(摘要)· 点击展开
OBJECTIVE: To investigate the value of plasma syndecan-1 (SDC-1) combined with lung ultrasonography in evaluating the degree of extravascular lung water in patients with acute respiratory distress syndrome (ARDS).
METHODS: From July 2018 to July 2019, 50 patients with ARDS admitted to the department of intensive care unit of Wuxi People's Hospital Affiliated to Nanjing Medical University were enrolled. After admission, pulse indicator continuous cardiac output (PiCCO) catheter was established for all patients. PiCCO indexes, including extravascular lung water index (EVLWI) and pulmonary vascular permeability index (PVPI) were monitored by one doctor. Another doctor performed lung ultrasound examination, and calculated the sum of the number of B-lines under 10 ultrasound sections of upper blue point, lower blue point, diaphragm point, Plaps point and rear blue point of both lungs. Then the level of plasma SDC-1 was detected by enzyme linked immunosorbent assay (ELISA). Pearson correlation method was used to analyze the correlation between the number of ultrasonic B-lines, plasma SDC-1 level and EVLWI and PVPI. Taking 10 mL/kg EVLWI as the boundary value, the degree of pulmonary edema in patients with ARDS was divided into mild pulmonary edema and severe pulmonary edema. The receiver operator characteristic curve (ROC curve) was drawn, and the number of B-lines, SDC-1 and the predictive value of the combination of the above two indicators on the severity of pulmonary edema in patients with ARDS were analyzed.
RESULTS: The cardiac index (CI) and central venous pressure (CVP) of 50 patients with ARDS were (46.84±6.00) mL×s-1×m-2 and (8.12±1.80) mmHg (1 mmHg = 0.133 kPa), cardiogenic pulmonary edema was excluded. In 50 patients with ARDS, EVLWI was (10.82±2.92) mL/kg, PVPI was 3.02±0.69, the number of ultrasound B-lines was 40.90±13.05, and plasma SDC-1 was (568.25±118.14) μg/L. Pearson correlation analysis showed that the number of ultrasound B-lines in patients with ARDS was significantly positively correlated with EVLWI and PVPI (r1 = 0.802, r2 = 0.799, both P < 0.01). Plasma SDC-1 was also positively correlated with EVLWI and PVPI (r1 = 0.732, r2 = 0.576, both P < 0.01). ROC curve analysis showed that the number of B-lines and SDC-1 had good predictive value for the severity of pulmonary edema in patients with ARDS. The area under ROC curve (AUC) and 95% confidence interval (95%CI) were 0.891 (0.803-0.979) and 0.875 (0.772-0.978), respectively. When the cut-off of B-lines was 40.50, the sensitivity and specificity were 82.1% and 86.4%, respectively. When the cut-off of SDC-1 was 559.37 μg/L, the sensitivity and specificity were 85.7% and 81.8%, respectively. Combining the number of B-lines with SDC-1 could further improve the predictive value of pulmonary water in patients with ARDS. The AUC (95%CI) was 0.958 (0.890-1.000), and the sensitivity and specificity were 92.9% and 91.8%, respectively.
CONCLUSIONS: The level of plasma SDC-1 and the number of pulmonary ultrasonic B-lines have a good correlation with the degree of extravascular lung water in patients with ARDS. The combined application of the two noninvasive indexes can be used to evaluate the degree of extravascular lung water in patients with ARDS.
参考来源
- Gao S, Wu D, Gao F, et al. [Evaluation of extravascular lung water in patients with acute respiratory distress syndrome by syndecan-1 combined with lung ultrasonography]. Zhonghua Wei Zhong Bing Ji Jiu Yi Xue. 2021. PMID: 34590569. doi:10.3760/cma.j.cn121430-20200121-00235
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。