COVID-19机械通气患者对较高呼气末正压的肺反应
结果显示5至15 cm H2O PEEP时氧合改善者36例(90%),但顺应性仅11例(28%)、Paco2仅14例(35%)改善。5至45 cm H2O复张351(161-462)mL、过度充气465(220-681)mL;5至15 cm H2O复张168(110-202)mL、过度充气121(63-270)mL。过度充气在所有患者中不同程度出现,且超过半数患者过度充气量大于复张量。提示高PEEP虽改善氧合,但可能因过度充气不改善顺应性和通气效率。
要点
- 5至15 cm H2O PEEP时氧合改善见于36例(90%),但顺应性仅11例(28%)、Paco2仅14例(35%)改善。
- 5至15 cm H2O PEEP时复张168(110-202)mL,过度充气121(63-270)mL;5至45 cm H2O时复张351(161-462)mL,过度充气465(220-681)mL。
- 过度充气在所有患者中不同程度出现,且超过半数患者过度充气量大于复张量。
- 早期COVID-19 ARDS仰卧位患者肺复张潜力大,但高PEEP下顺应性和Paco2不普遍改善,可能因过度充气。
- PEEP试验中需同时评估氧合、顺应性和Paco2,不应仅以氧合改善作为上调PEEP的依据。
适用人群与场景
- 插管3天内的COVID-19 ARDS患者,仰卧位通气。
诊断标准与关键阈值
- 复张定义为非充气肺区(密度高于-100 HU)体积减少;过度充气定义为过度充气肺区(密度低于-900 HU)体积增加。
- PEEP试验设置5、10、15 cm H2O,其他通气设置不变。
处置流程与药物剂量
- 第一步:对早期COVID-19 ARDS仰卧位患者进行PEEP试验,设置5、10、15 cm H2O,其他通气设置不变。
- 第二步:在每一PEEP水平测量氧合、顺应性和Paco2。
- 第三步:综合评估氧合、顺应性和Paco2变化,警惕过度充气;原文未给出具体PEEP调整阈值或目标值。
红旗征与不能漏的情况
- 高PEEP下氧合改善但顺应性和Paco2不改善,提示可能存在过度充气,原文未给出具体处理措施。
研究设计与关键结果
- 干预:PEEP试验(5、10、15 cm H2O),20例在5和45 cm H2O、另20例在5和15 cm H2O行全肺静态CT。
- 主要结果:5至15 cm H2O PEEP时氧合改善36例(90%),顺应性改善11例(28%),Paco2改善14例(35%)。
- CT结果:5至45 cm H2O复张351(161-462)mL、过度充气465(220-681)mL;5至15 cm H2O复张168(110-202)mL、过度充气121(63-270)mL。
- 过度充气在所有患者中不同程度出现,超过半数患者过度充气量大于复张量。
证据类型、等级与局限
- 证据类型:前瞻性观察性研究(非RCT);原文未给出证据等级或推荐强度。
对床旁实践的改变
- 对早期COVID-19 ARDS仰卧位患者,不应仅因氧合改善而常规上调PEEP至>10 cm H2O,需同时评估顺应性和Paco2以警惕过度充气。
- PEEP试验中应综合氧合、顺应性和Paco2判断肺反应,原文未给出具体决策阈值。
- 适用人群为插管3天内的COVID-19 ARDS仰卧位患者;原文未提及不适用人群。
指南或共识出处
- 原文未提及
以上提炼依据论文摘要(全文未开放获取,或许可不允许翻译转载);全文请点「阅读原文」。
英文原文(摘要)· 点击展开
BACKGROUND: International guidelines suggest using a higher (> 10 cm H2O) positive end-expiratory pressure (PEEP) in patients with moderate-to-severe ARDS due to COVID-19. However, even if oxygenation generally improves with a higher PEEP, compliance, and Paco2 frequently do not, as if recruitment was small.
RESEARCH QUESTION: Is the potential for lung recruitment small in patients with early ARDS due to COVID-19?
STUDY DESIGN AND METHODS: Forty patients with ARDS due to COVID-19 were studied in the supine position within 3 days of endotracheal intubation. They all underwent a PEEP trial, in which oxygenation, compliance, and Paco2 were measured with 5, 10, and 15 cm H2O of PEEP, and all other ventilatory settings unchanged. Twenty underwent a whole-lung static CT scan at 5 and 45 cm H2O, and the other 20 at 5 and 15 cm H2O of airway pressure. Recruitment and hyperinflation were defined as a decrease in the volume of the non-aerated (density above -100 HU) and an increase in the volume of the over-aerated (density below -900 HU) lung compartments, respectively.
RESULTS: From 5 to 15 cm H2O, oxygenation improved in 36 (90%) patients but compliance only in 11 (28%) and Paco2 only in 14 (35%). From 5 to 45 cm H2O, recruitment was 351 (161-462) mL and hyperinflation 465 (220-681) mL. From 5 to 15 cm H2O, recruitment was 168 (110-202) mL and hyperinflation 121 (63-270) mL. Hyperinflation variably developed in all patients and exceeded recruitment in more than half of them.
INTERPRETATION: Patients with early ARDS due to COVID-19, ventilated in the supine position, present with a large potential for lung recruitment. Even so, their compliance and Paco2 do not generally improve with a higher PEEP, possibly because of hyperinflation.
参考来源
- Protti A, Santini A, Pennati F, et al. Lung Response to a Higher Positive End-Expiratory Pressure in Mechanically Ventilated Patients With COVID-19. Chest. 2021. PMID: 34666011. doi:10.1016/j.chest.2021.10.012
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。