文献速递呼吸衰竭与机械通气重症综合管理与镇静镇痛

液体平衡与重症监护病房患者呼吸机相关事件的关系:一项巢式病例对照研究

Fluid Balance and Ventilator-Associated Events Among Patients Admitted to ICUs in China: A Nested Case-Control Study.
PubMed 文献 · Crit Care Med · 2022-01-01
一句话结论4天累积液体平衡在-1至0 L时呼吸机相关事件风险最低,正平衡增加风险且呈剂量依赖,负平衡未见风险增加。

该研究为基于华西医院ICU医疗保健相关感染登记系统的巢式病例对照研究,纳入1528例呼吸机相关事件病例和3038例匹配对照,均机械通气至少4天。计算事件发生前4天累积液体平衡,采用加权Cox比例风险模型及限制性立方样条分析剂量反应关系。结果显示液体平衡与全部三层级呼吸机相关事件均呈非线性关系,-1至0 L风险最低(非线性检验P<0.05);正平衡显著增加风险(4天累积1 L:HR 1.19;3 L:1.92;5 L:2.58;7 L:3.24),负平衡未见风险增加(-5 L:1.34;-3 L:1.14;-1 L:0.98)。提示ICU机械通气患者应避免正液体平衡。

要点

  • 机械通气≥4天的ICU患者,事件前4天累积液体平衡在-1至0 L时呼吸机相关事件风险最低。
  • 正液体平衡增加呼吸机相关事件风险且呈剂量依赖:4天累积1 L HR 1.19,3 L HR 1.92,5 L HR 2.58,7 L HR 3.24。
  • 负液体平衡未见呼吸机相关事件风险增加:4天累积-5 L HR 1.34,-3 L HR 1.14,-1 L HR 0.98。
  • 液体平衡与全部三层级呼吸机相关事件均呈非线性关系(非线性检验P<0.05)。
  • 该研究为观察性巢式病例对照,不能确立液体平衡与呼吸机相关事件的因果关系。

适用人群与场景

  • 纳入1528例呼吸机相关事件病例与3038例匹配对照。

诊断标准与关键阈值

  • 呼吸机相关事件按原文所述三层级定义判定(原文未给出具体各层级诊断界值)。
  • 累积液体平衡计算窗口为呼吸机相关事件发生前4天。
  • 液体平衡与呼吸机相关事件风险最低的区间为-1至0 L。

处置流程与药物剂量

  • 原文未提及具体液体治疗药物、剂量、给药途径或目标值。
  • 基于观察性结果,原文提示避免正液体平衡可能降低呼吸机相关事件风险,但未给出可执行的液体管理方案。

红旗征与不能漏的情况

  • 原文未提及红旗征或需要立刻处理的情况。

研究设计与关键结果

  • 研究类型为巢式病例对照研究,样本量1528例病例与3038例对照,单中心系统(华西医院ICU登记库)。
  • 液体平衡与全部三层级呼吸机相关事件呈非线性关系,-1至0 L风险最低(非线性检验P<0.05)。
  • 正液体平衡增加呼吸机相关事件风险:4天累积1 L HR 1.19;3 L HR 1.92;5 L HR 2.58;7 L HR 3.24。
  • 负液体平衡未见风险增加:4天累积-5 L HR 1.34;-3 L HR 1.14;-1 L HR 0.98。

证据类型、等级与局限

  • 证据类型:巢式病例对照研究(观察性研究)。
  • 局限:单中心登记系统来源、观察性设计不能确立因果、原文未提及其他局限。

对床旁实践的改变

  • 对机械通气≥4天的ICU患者,可关注避免正累积液体平衡,因正平衡与呼吸机相关事件风险增加相关。
  • 液体平衡-1至0 L与最低风险相关,但原文未推荐将负平衡作为目标,因负平衡未见风险增加亦未见获益。
  • 该研究为观察性设计,不能据此改变液体复苏或利尿的具体决策,需结合患者容量状态个体化判断。
  • 常见陷阱:将观察性剂量反应关系误读为因果或治疗阈值;原文未提供干预方案,不能据此设定液体管理目标。

指南或共识出处

  • 原文未提及

以上提炼依据论文摘要(全文未开放获取,或许可不允许翻译转载);全文请点「阅读原文」。

英文原文(摘要)· 点击展开

OBJECTIVES: Fluid therapy is an important component of intensive care management, however, optimal fluid management is unknown. The relationship between fluid balance and ventilator-associated events has not been well established. This study investigated the dose-response relationship between fluid balance and ventilator-associated events.

DESIGN: Nested case-control study.

SETTING: The study was based on a well-established, research-oriented registry of healthcare-associated infections at ICUs of West China Hospital system (Chengdu, China).

PATIENTS: A total of 1,528 ventilator-associated event cases with 3,038 matched controls, who consistently underwent mechanical ventilation for at least 4 days from April 1, 2015, to December 31, 2018, were included.

INTERVENTIONS: None.

MEASUREMENTS AND MAIN RESULTS: We calculated cumulative fluid balance within 4 days prior to ventilator-associated event occurrence. A weighted Cox proportional hazards model with restricted cubic splines was used to evaluate the dose-response relationship. A nonlinear relationship between fluid balance and all three tiers of ventilator-associated events, patients with fluid balance between -1 and 0 L had the lowest risk (p < 0.05 for nonlinear test). The risk of ventilator-associated event was significantly higher in patients with positive fluid balance (4 d cumulative fluid balance: 1 L: 1.19; 3 L: 1.92; 5 L: 2.58; 7 L: 3.24), but not in those with negative fluid balance (-5 L: 1.34; -3 L: 1.14; -1 L: 0.98).

CONCLUSIONS: There was nonlinear relationship between fluid balance and all three tiers of ventilator-associated event, with an fluid balance between -1 and 0 L corresponding to the lowest risk. Positive but not negative fluid balance increased the risk of ventilator-associated events, with higher positive fluid balance more likely to lead to ventilator-associated events.

来源:Crit Care Med,查看原文。版权归原作者所有。

参考来源

  1. Wang W, Zhu S, He Q, et al. Fluid Balance and Ventilator-Associated Events Among Patients Admitted to ICUs in China: A Nested Case-Control Study. Crit Care Med. 2022. PMID: 34473657. doi:10.1097/CCM.0000000000005227

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。