院外心肺复苏中通气时胸外按压导致气流碎裂

Chest compressions during ventilation in out-of-hospital cardiopulmonary resuscitation cause fragmentation of the airflow.
PubMed 文献 · Am J Emerg Med · 2021-08-17
一句话结论院外心脏骤停患者通气时同步胸外按压普遍造成气流碎裂,平均每次吸气3个碎片、每碎片214mL,可能削弱通气有效性,需进一步研究。

本研究为单中心观察性研究,在Ghent大学医院开展,纳入10例院前插管并由医疗急救团队复苏的成年心脏骤停患者,使用定制双向流量传感器量化通气量。患者通气和胸外按压同步进行,计算通气量及气流碎裂的数量和体积。结果显示所有患者均出现气流碎裂,平均每次吸气3个碎片(范围2-5),每碎片平均体积214mL(标准差65;范围112-341),患者间变异大。作者认为量化气流体积及碎裂对通气有效性的影响对改进心肺复苏技术可能至关重要,需进一步研究。

要点

  • 所有10例院前插管成年心脏骤停患者通气时同步胸外按压均出现气流碎裂,平均每次吸气3个碎片(范围2-5)。
  • 气流碎裂平均每碎片体积214mL(标准差65;范围112-341),患者间数量和体积变异大。
  • 平均通气频率12/min(标准差2;范围9-16),平均分钟通气量6.21L(标准差1.51;范围3.79-8.15),平均潮气量514mL(标准差99;范围422-682)。
  • 气流碎裂可能削弱通气有效性,但本研究未评估其对临床结局的影响。
  • 需进一步研究量化气流体积及碎裂对通气有效性的影响,以改进心肺复苏技术。

适用人群与场景

  • 成人心脏骤停患者,院前由医疗急救团队插管并复苏,且通气和胸外按压同步进行;单中心研究在Ghent大学医院开展。

诊断标准与关键阈值

  • 原文未提及

处置流程与药物剂量

  • 原文未提及

红旗征与不能漏的情况

  • 原文未提及

研究设计与关键结果

  • 单中心观察性研究,纳入10例患者(7例男性),平均年龄71岁(标准差14;范围51-87),使用定制双向流量传感器量化通气量。
  • 所有患者均出现气流碎裂,平均每次吸气3个碎片(标准差1;范围2-5),每碎片平均体积214mL(标准差65;范围112-341)。
  • 平均通气频率12/min(标准差2;范围9-16),平均分钟通气量6.21L(标准差1.51;范围3.79-8.15),平均潮气量514mL(标准差99;范围422-682)。
  • 患者间气流碎裂的数量和体积变异大。

证据类型、等级与局限

  • 单中心观察性研究,样本量小(10例),无对照组,未评估气流碎裂对临床结局的影响;原文未给出证据等级或推荐强度。

对床旁实践的改变

  • 提示在院前插管成年心脏骤停患者中,通气时同步胸外按压普遍导致气流碎裂,临床应关注通气有效性,但本研究未提供改变具体通气策略(如按压与通气时序)的证据。

指南或共识出处

  • 原文未提及

以上提炼依据论文摘要(全文未开放获取,或许可不允许翻译转载);全文请点「阅读原文」。

英文原文(摘要)· 点击展开

INTRODUCTION: When a patient suffers an out-of-hospital cardiac arrest, ventilation and chest compressions are often given simultaneously during cardiopulmonary resuscitation. These simultaneous chest compressions may cause a fragmentation of the airflow, which may lead to an ineffective ventilation. This study focusses on the occurrence and quantification of this fragmentation and its effect on ventilation.

MATERIALS AND METHODS: This study is a single-center observational study, held at Ghent University Hospital. A custom-built bidirectional flow sensor was used to quantify the volumes of ventilation. Adult cardiac arrest patients who were prehospitally intubated and resuscitated by the medical emergency team were eligible for inclusion. Data of the patients who were ventilated and received simultaneous chest compressions, was used to calculate the volumes of ventilation and the amount and volumes of fragmentation. All data in this study is reported as mean (standard deviation; range).

RESULTS: Data of 10 patients (7 male) with a mean age of 71 years (14;51-87) was used in this study. The mean ventilation frequency was 12/min (2;9-16), the mean minute volume and tidal volume were respectively 6.21 L (1.51;3.79-8.15) and 514 mL (99;422-682). Fragmentation of the airflow was observed in all patients, with an average of 3 (1;2-5) fragments per inspiration and a mean volume of 214 mL (65;112-341) per fragment.

DISCUSSION AND CONCLUSION: Chest compressions during ventilation caused fragmentation of the airflow in all patients. There was wide variation in the number and volume of the fragments between patients. The importance of quantification of airflow volumes and the effect fragmentation of the airflow on the efficacy of ventilation can be essential in improving cardiopulmonary resuscitation techniques and therefore needs further investigation.

来源:Am J Emerg Med,查看原文。版权归原作者所有。

参考来源

  1. Van Den Daele C, Vanwulpen M, Hachimi-Idrissi S, et al. Chest compressions during ventilation in out-of-hospital cardiopulmonary resuscitation cause fragmentation of the airflow. Am J Emerg Med. 2021. PMID: 34492591. doi:10.1016/j.ajem.2021.08.028

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。