云南省不同海拔地区急性呼吸窘迫综合征患者脉搏血氧饱和度/吸入氧浓度与动脉血氧分压/吸入氧浓度评估氧合的对比研究
该研究纳入2019年1月至2020年12月云南省不同海拔地区(约1800米、2200米、3200米)的ARDS患者,按海拔分三组,分别给予不同氧疗并记录SpO2、FiO2、PaO2。结果显示三组PaO2/FiO2与SpO2/FiO2均高度相关(r分别为0.830、0.951、0.828,均P<0.05),并拟合出各组回归方程。ROC分析给出各组在不同PaO2/FiO2阈值下对应的SpO2/FiO2界值及敏感度和特异度。结论认为无创SpO2/FiO2可替代PaO2/FiO2评估不同海拔ARDS患者的氧合。
要点
- 三组ARDS患者PaO2/FiO2与SpO2/FiO2均高度相关:组1 r=0.830、组2 r=0.951、组3 r=0.828,均P<0.05。
- 组1(约1800米)PaO2/FiO2为100 mmHg和200 mmHg时,对应SpO2/FiO2界值分别为155和252,敏感度84.9%和100%,特异度87.2%和70.6%。
- 组2(约3200米)PaO2/FiO2为100 mmHg和200 mmHg时,对应SpO2/FiO2界值分别为219和432,敏感度100%和85.2%,特异度82.5%和100%。
- 组3(约2200米)PaO2/FiO2为200 mmHg和300 mmHg时,对应SpO2/FiO2界值分别为319和452,敏感度均为100%,特异度80.9%和86.2%。
- PEEP、FiO2和动脉血pH可影响SpO2/FiO2与PaO2/FiO2之间的相关性。
适用人群与场景
- 组1:昆明医科大学第一附属医院重症医学科中重度ARDS患者,平均海拔约1800米,接受机械通气。
- 组2:迪庆藏族自治州人民医院重症医学科中重度ARDS患者,平均海拔约3200米。
- 组3:丽江市人民医院急诊科收治的轻度至中重度ARDS患者,平均海拔约2200米。
诊断标准与关键阈值
- 组1:机械通气维持SpO2在0.90-0.96、低FiO2超过30分钟后记录SpO2、FiO2、PaO2。
- 组2:储氧面罩吸氧维持SpO2在0.90-0.96共10分钟后记录SpO2、FiO2、PaO2。
- 组3:SpO2<0.90时给予储氧面罩吸氧,记录维持SpO2≥0.90所需FiO2,吸氧10分钟后记录SpO2、FiO2、PaO2。
研究设计与关键结果
- 研究类型为不同海拔地区的对比研究;组1纳入24例ARDS患者、采集271次血气分析,组2纳入14例、采集47次,组3纳入76例、采集76次。
- 组1、2、3的PaO2/FiO2分别为103(79,130)、168(98,195)、232(146,271)mmHg,SpO2/FiO2分别为157(128,190)、419(190,445)、319(228,446);组1两者最低,组3最高。
- 回归方程:组1 SpO2/FiO2=58+0.97×PaO2/FiO2(R2=0.548,P<0.001);组2 SpO2/FiO2=6+2.13×PaO2/FiO2(R2=0.938,P<0.001);组3 SpO2/FiO2=53+1.33×PaO2/FiO2(R2=0.828,P<0.001)。
- ROC分析:组1中重度ARDS的AUC为0.848和0.916;组2中重度ARDS的AUC为0.945和0.977;组3轻至中重度ARDS的AUC为0.903和0.936。
- PEEP、FiO2和动脉血pH可影响SpO2/FiO2与PaO2/FiO2的相关性。
证据类型、等级与局限
- 证据类型:单篇对比研究(不同海拔分组观察)。
- 局限:原文未报告局限性。
对床旁实践的改变
- 作者认为,云南省不同海拔地区ARDS患者的SpO2/FiO2与PaO2/FiO2有良好相关性,无创SpO2/FiO2可用于替代PaO2/FiO2评估氧合。
- PEEP、FiO2和动脉血pH可影响SpO2/FiO2与PaO2/FiO2的相关性,解读时需结合这些因素。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
OBJECTIVE: To investigate and evaluate if pulse oxygen saturation/fraction of inhaled oxygen (SpO2/FiO2) can be used, as replacement of arterial partial pressure of oxygen/fraction of inhaled oxygen (PaO2/FiO2), to assess oxygenation in acute respiratory distress syndrome (ARDS) patients at different high altitudes in Yunnan Province, and to find a rapid and non-invasive method for the diagnosis of ARDS at different altitudes.
METHODS: Patients with ARDS at different high altitudes in Yunnan Province from January 2019 to December 2020 were enrolled. The patients were divided into three groups according to different altitudes, and received different oxygen therapies according to their respective medical conditions. Group 1 consisted of patients with moderate to severe ARDS from the department of critical care medicine of the First Affiliated Hospital of Kunming Medical University (average altitude approximately 1 800 m), and received mechanical ventilation to maintain SpO2 of 0.90-0.96 with a low FiO2 for more than 30 minutes, and SpO2, FiO2, PaO2 were recorded. Group 2 consisted of patients with moderate to severe ARDS at the department of critical care medicine of People's Hospital of Diqing Tibetan Autonomous Prefecture (mean altitude about 3 200 m), and received oxygen with an attached reservoir mask to maintain SpO2 of 0.90-0.96 for 10 minutes, and then SpO2, FiO2, and PaO2 were recorded. Group 3 consisted of patients with mild to moderate-severe ARDS who admitted to the emergency department of the People's Hospital of Lijiang (average altitude approximately 2 200 m); when SpO2 < 0.90, patients received oxygen with the oxygen storage mask, and the FiO2 required to maintain SpO2 ≥ 0.90 was recorded, and SpO2, FiO2, PaO2 were recorded after oxygen inhalation for 10 minutes. Spearman coefficient was used to analyze the correlation between SpO2/FiO2 and PaO2/FiO2 in each group. Linear analysis was used to derive the linear equation between SpO2/FiO2 and PaO2/FiO2, and to evaluate arterial pH, arterial partial pressure of carbon dioxide (PaCO2), FiO2, tidal volume (VT), positive end-expiratory pressure (PEEP) and other related factors which would change the correlation between SpO2/FiO2 and PaO2/FiO2. The receiver operator characteristic curve (ROC curve) was plotted to calculate the sensitivity and specificity of using SpO2/FiO2 instead of PaO2/FiO2 to assess oxygenation of ARDS patients.
RESULTS: Group 1 consisted of 24 ARDS patients from whom 271 blood gas analysis results were collected; group 2 consisted of 14 ARDS patients from whom a total of 47 blood gas analysis results were collected; group 3 consisted of 76 ARDS patients, and a total of 76 blood gas analysis results were collected. The PaO2/FiO2 (mmHg, 1 mmHg = 0.133 kPa) in groups 1, 2 and 3 were 103 (79, 130), 168 (98, 195) and 232 (146, 271) respectively, while SpO2/FiO2 were 157 (128, 190), 419 (190, 445) and 319 (228, 446) respectively. Among the three groups, patients in group 1 had the lowest PaO2/FiO2 and SpO2/FiO2, while patients in group 3 had the highest. Spearman correlation analysis showed that PaO2/FiO2 was highly correlated with SpO2/FiO2 in groups 1, 2 and 3 (r values were 0.830, 0.951, 0.828, all P < 0.05). Regression equation was fitted according to linear analysis: in group 1 SpO2/FiO2 = 58+0.97×PaO2/FiO2 (R2 = 0.548, P < 0.001); in group 2 SpO2/FiO2 = 6+2.13×PaO2/FiO2 (R2 = 0.938, P < 0.001); in group 3 SpO2/FiO2 = 53+1.33×PaO2/FiO2 (R2 = 0.828, P < 0.001). Further analysis revealed that PEEP, FiO2, and arterial blood pH could affect the correlation between SpO2/FiO2 and PaO2/FiO2. ROC curve analysis showed that the area under ROC curve (AUC) was 0.848 and 0.916 in group 1 with moderate to severe ARDS; based on the regression equation, the corresponding SpO2/FiO2 cut-off values at a PaO2/FiO2 of 100 mmHg and 200 mmHg were 155, 252 with a sensitivity of 84.9% and 100%, specificity of 87.2% and 70.6%, respectively. Patients with moderate to severe ARDS in group 2 (AUC was 0.945 and 0.977), the corresponding SpO2/FiO2 cut-off values at PaO2/FiO2 of 100 mmHg and 200 mmHg were 219 and 432 with the sensitivity of 100% and 85.2%, specificity of 82.5% and 100%, respectively. Patients with mild to moderate-severe ARDS in group 3 (AUC was 0.903 and 0.936), the corresponding SpO2/FiO2 cut-off values at a PaO2/FiO2 of 200 mmHg and 300 mmHg were 319 and 452 with the sensitivity of 100% and 100%, specificity of 80.9% and 86.2%, respectively.
CONCLUSIONS: SpO2/FiO2 and PaO2/FiO2 in ARDS patients at different high altitudes in Yunnan Province have a good correlation, and non-invasive SpO2/FiO2 can be used to replace PaO2/FiO2 to assess the oxygenation in ARDS patients.
参考来源
- Xu W, Li C, Chen Y, et al. [Comparison of pulse oxygen saturation/fraction of inhaled oxygen and arterial partial pressure of oxygen/fraction of inhaled oxygen in the assessment of oxygenation in acute respiratory distress syndrome patients at different high altitudes in Yunnan Province]. Zhonghua Wei Zhong Bing Ji Jiu Yi Xue. 2021. PMID: 34412752. doi:10.3760/cma.j.cn121430-20210301-00303
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。