文献速递呼吸衰竭与机械通气重症综合管理与镇静镇痛

COVID-19患者对肺保护性通气的依从性

Adherence to Lung Protective Ventilation in Patients With Coronavirus Disease 2019.
PubMed 文献 · Crit Care Explor · 2021-08-10
一句话结论回顾性队列显示,COVID-19相关ARDS患者前72小时低潮气量通气依从性高于非COVID-19 ARDS患者。

这项回顾性队列研究在单一医疗系统5家医院开展,纳入333例COVID-19机械通气患者和234例非COVID-19 ARDS患者。COVID-19组初始潮气量为6.4 cc/kg预测体重,非COVID-19组为6.8 cc/kg预测体重;前72小时内潮气量≤6.5 cc/kg预测体重的时间占比分别为70%和52%(未校正P<0.001)。校正身高、性别、入院医院和是否入住内科专科ICU后,COVID-19诊断与前72小时潮气量≤6.5 cc/kg预测体重时间占比高21%相关(95%CI 14-28%,P<0.001)。提示COVID-19相关ARDS可能是理解肺保护性通气实施促进因素的窗口。

要点

  • COVID-19组前72小时潮气量≤6.5 cc/kg预测体重的时间占比为70%,非COVID-19 ARDS组为52%(未校正P<0.001)。
  • 初始潮气量:COVID-19组平均6.4 cc/kg预测体重,非COVID-19 ARDS组平均6.8 cc/kg预测体重。
  • 校正身高、性别、入院医院和内科专科ICU入住后,COVID-19诊断与前72小时达标时间占比高21%独立相关(95%CI 14-28%,P<0.001)。
  • 研究纳入333例COVID-19和234例非COVID-19 ARDS机械通气患者,ARDS由临床在用的自动化电子ARDS查找器识别。
  • 两组均未完全达到低潮气量目标,非COVID-19 ARDS组依从性更低,提示诊断不确定性可能是实施障碍。

适用人群与场景

  • 单一医疗系统5家医院中,经自动化电子ARDS查找器识别的机械通气COVID-19或非COVID-19 ARDS患者。
  • 研究为回顾性队列,无排除标准描述。

诊断标准与关键阈值

  • ARDS由研究医院临床在用的自动化电子ARDS查找器识别。
  • 低潮气量依从性以潮气量≤6.5 cc/kg预测体重的时间占比衡量,评价窗口为机械通气前72小时。

处置流程与药物剂量

  • 原文未提及

红旗征与不能漏的情况

  • 原文未提及

研究设计与关键结果

  • 研究类型:回顾性队列研究,5家医院,333例COVID-19患者和234例非COVID-19 ARDS患者。
  • 干预:无;比较两组低潮气量通气依从性。
  • 主要结果:COVID-19组初始潮气量6.4 cc/kg预测体重,非COVID-19组6.8 cc/kg预测体重;前72小时潮气量≤6.5 cc/kg预测体重时间占比分别为70%和52%(未校正P<0.001)。
  • 校正后:COVID-19诊断与前72小时达标时间占比高21%相关(95%CI 14-28%,P<0.001),校正因素包括身高、性别、入院医院和是否入住内科专科ICU。

证据类型、等级与局限

  • 证据类型:回顾性队列研究。
  • 局限:单医疗系统5家医院、回顾性设计、依赖自动化电子ARDS查找器识别ARDS、样本量有限、未描述排除标准。

对床旁实践的改变

  • 提示COVID-19相关ARDS患者低潮气量通气依从性高于非COVID-19 ARDS,但不能据此认为非COVID-19 ARDS无需加强低潮气量实施。
  • 两组均未完全达标(非COVID-19组仅52%时间达标),应继续在床旁监测潮气量是否≤6.5 cc/kg预测体重。
  • 研究为观察性关联,不能推断COVID-19诊断本身改善依从性,适用与不适用人群原文未明确界定。

指南或共识出处

  • 原文未提及

以上提炼依据论文摘要(全文未开放获取,或许可不允许翻译转载);全文请点「阅读原文」。

英文原文(摘要)· 点击展开

UNLABELLED: Prior studies have demonstrated suboptimal adherence to lung protective ventilation among patients with acute respiratory distress syndrome. A common barrier to providing this evidence-based practice is diagnostic uncertainty. We sought to test the hypothesis that patients with acute respiratory distress syndrome due to coronavirus disease 2019, in whom acute respiratory distress syndrome is easily recognized, would be more likely to receive low tidal volume ventilation than concurrently admitted acute respiratory distress syndrome patients without coronavirus disease 2019.

DESIGN: Retrospective cohort study.

SETTING: Five hospitals of a single health system.

PATIENTS: Mechanically ventilated patients with coronavirus disease 2019 or noncoronavirus disease 2019 acute respiratory distress syndrome as identified by an automated, electronic acute respiratory distress syndrome finder in clinical use at study hospitals.

INTERVENTIONS: None.

MEASUREMENTS AND MAIN RESULTS: Among 333 coronavirus disease 2019 patients and 234 noncoronavirus disease 2019 acute respiratory distress syndrome patients, the average initial tidal volume was 6.4 cc/kg predicted body weight and 6.8 cc/kg predicted body weight, respectively. Patients had tidal volumes less than or equal to 6.5 cc/kg predicted body weight for a mean of 70% of the first 72 hours of mechanical ventilation in the coronavirus disease 2019 cohort, compared with 52% in the noncoronavirus disease 2019 cohort (unadjusted p < 0.001). After adjusting for height, gender, admitting hospital, and whether or not the patient was admitted to a medical specialty ICU, coronavirus disease 2019 diagnosis was associated with a 21% higher percentage of time receiving tidal volumes less than or equal to 6.5 cc/kg predicted body weight within the first 72 hours of mechanical ventilation (95% CI, 14-28%; p < 0.001).

CONCLUSIONS: Adherence to low tidal volume ventilation during the first 72 hours of mechanical ventilation is higher in patients with coronavirus disease 2019 than with acute respiratory distress syndrome without coronavirus disease 2019. This population may present an opportunity to understand facilitators of implementation of this life-saving evidence-based practice.

来源:Crit Care Explor,查看原文。版权归原作者所有。

参考来源

  1. Levy E, Scott S, Tran T, et al. Adherence to Lung Protective Ventilation in Patients With Coronavirus Disease 2019. Crit Care Explor. 2021. PMID: 34396146. doi:10.1097/CCE.0000000000000512

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。