文献速递复苏、休克与脓毒症心脑血管急症

单手与双手成人胸外按压力量分布的生物力学分析:随机交叉观察研究

Biomechanical analysis of force distribution in one-handed and two-handed adult chest compression: a randomised crossover observational study.
PubMed 文献 · Emerg Med J · 2021-08-17
一句话结论标准双手胸外按压在按压深度、深度准确率、回弹不完全比例及操作者疲劳方面均优于单手按压,单手按压还导致更大的尺桡侧力量差。

该随机交叉观察研究纳入来自医院和消防救护队的参与者,在Resusci Anne模拟人上按2015标准分别行单手和双手胸外按压,用MatScan压力测量系统分析按压压力与力量分布。双手按压的按压深度中位数、深度准确率比例和回弹不完全比例均优于单手按压,最大力量和尺桡侧力量差在双手按压中更小,操作者感知疲劳也更低。结论提示单手胸外按压质量较差且更易致操作者疲劳,应调整单手按压培训以潜在改善转运期间心肺复苏质量。

要点

  • 双手胸外按压的按压深度中位数(IQR)为51.00(41.50–54.75)mm,优于单手按压的42.00(27.00–49.00)mm,p=0.018。
  • 双手按压的深度准确率比例(IQR)为82.05%(13.95%–99.86%),高于单手按压的11.17%(0.00%–42.13%),p=0.028。
  • 双手按压的回弹不完全比例(IQR)为0.23%(0.01%–0.44%),低于单手按压的2.42%(0.60%–4.21%),p=0.002。
  • 单手按压的尺桡侧力量差(IQR)为23.93(11.19–38.74)kgf,大于双手按压的7.13(-16.58–21.07)kgf,p<0.001,提示单手按压导致手部更大尺偏。
  • 操作者感知疲劳评分双手按压为5.00(3.00–6.00),低于单手按压的6.00(5.00–8.00),p<0.001。

适用人群与场景

  • 从国立成功大学医院和消防局救护队招募的参与者,在Resusci Anne模拟人上执行胸外按压;原文未提及患者人群的纳入或排除标准。

诊断标准与关键阈值

  • 按压操作依据2015标准胸外按压指南执行;原文未提及诊断标准或启动/停止阈值。

处置流程与药物剂量

  • 原文未提及具体处置流程或药物剂量;研究仅比较单手与双手胸外按压的技术操作。

红旗征与不能漏的情况

  • 原文未提及

研究设计与关键结果

  • 研究类型为随机交叉观察研究,参与者来自国立成功大学医院和消防局救护队,在Resusci Anne模拟人上按2015标准分别行单手和双手胸外按压,使用MatScan压力测量系统评估。
  • 双手按压对比单手按压:按压深度中位数(IQR)51.00(41.50–54.75)mm vs 42.00(27.00–49.00)mm,p=0.018;深度准确率比例82.05%(13.95%–99.86%)vs 11.17%(0.00%–42.13%),p=0.028;回弹不完全比例0.23%(0.01%–0.44%)vs 2.42%(0.60%–4.21%),p=0.002。
  • 最大力量(IQR)双手按压为45.72(36.10–80.84)kgf,单手按压为35.64(24.13–74.34)kgf,p<0.001;尺桡侧力量差(IQR)双手按压为7.13(-16.58–21.07)kgf,单手按压为23.93(11.19–38.74)kgf,p<0.001。
  • 操作者感知疲劳评分(IQR)双手按压为5.00(3.00–6.00),单手按压为6.00(5.00–8.00),p<0.001。

证据类型、等级与局限

  • 证据类型为随机交叉观察研究;原文未给出证据等级或推荐强度。
  • 局限:原文未明确说明样本量、中心数及盲法等信息;研究在模拟人上进行,结论外推至临床患者需谨慎。

对床旁实践的改变

  • 在临床或转运条件下,若考虑使用单手胸外按压,需认识到其按压深度、深度准确率和回弹质量均劣于标准双手按压,且更易导致操作者疲劳和手部尺偏。
  • 原文建议调整单手胸外按压的培训,以潜在改善转运期间心肺复苏的质量;未提及对双手按压标准实践的改变。

指南或共识出处

  • 原文未提及

以上提炼依据论文摘要(全文未开放获取,或许可不允许翻译转载);全文请点「阅读原文」。

英文原文(摘要)· 点击展开

INTRODUCTION: The standard method of chest compression for adults is a two-handed procedure. One-handed external chest compression (ECC) is used in some situations such as during transport of patients who had an out-of-hospital cardiac arrest, but the quality of one-handed ECC is still not well known. The distribution of force is related to the quality of chest compression and may affect the risk of injury. This study aimed to determine the differences in the quality and potential safety concern between one-handed ECC and two- handed ECC.

METHODS: In this randomised crossover study, participants recruited from National Cheng Kung University Hospital and the ambulance team from the fire bureau were asked to perform one-handed and two-handed ECC on the Resusci Anne manikin according to standard 2015 ECC guidelines. The MatScan Pressure Measurement system was used to investigate the compression pressure and force distribution.

RESULTS: Two-handed ECC had better results than one-handed ECC in terms of the median (IQR) depth (51.00 (41.50-54.75) mm vs 42.00 (27.00-49.00) mm, p=0.018), the proportion of depth accuracy (82.05% (13.95%-99.86%) vs 11.17% (0.00%-42.13%), p=0.028) and the proportion of incomplete recoil (0.23% (0.01%-0.44%) vs 2.42% (0.60%-4.21%), p=0.002). The maximum force (45.72 (36.10-80.84) kgf vs 35.64 (24.13-74.34) kgf, p<0.001) and ulnar-radial force difference (7.13 (-16.58 to 21.07) kgf vs 23.93 (11.19-38.74) kgf, p<0.001) showed statistically significant differences. The perceived fatigue of two-handed ECC versus one-handed ECC was 5.00 (3.00-6.00) vs 6.00 (5.00-8.00), p<0.001.

CONCLUSION: The quality of one-handed ECC, based on depth and recoil, is worse than that of standard two-handed ECC. The pressure and force distribution of one-handed ECC result in greater ulnar pronation of the hand than that of two-handed ECC. One-handed ECC more easily causes operator fatigue. Acknowledging these findings and adjusting training for one-handed ECC would potentially improve the quality of cardiopulmonary resuscitation during transport.

来源:Emerg Med J,查看原文。版权归原作者所有。

参考来源

  1. Kao CL, Tsou JY, Hong MY, et al. Biomechanical analysis of force distribution in one-handed and two-handed adult chest compression: a randomised crossover observational study. Emerg Med J. 2021. PMID: 34404678. doi:10.1136/emermed-2020-210363

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。