经眼脑阻抗指数在猪低血压与脑自动调节扰动模型中预测压力反应性指数变化
该研究在Yorkshire猪上通过控制性失血(25-35分钟内去除总血量的30-40%,目标MAP约35 mmHg、呼气末二氧化碳>28 mmHg)建立低血压与脑自动调节扰动模型,用眼睑电极记录经眼脑阻抗(TOBI),计算dz(呼吸诱导阻抗变化幅度)和DZx(dz与MAP的移动Pearson相关),并与PRx比较。结果显示dz与MAP、ICP、CPP、CBF高度相关(r=-0.823、-0.723、-0.813、-0.726,p<0.0001),失血期间CPP和CBF分别平均下降54.2%和28.3%,dz增加277%;DZx预测PRx的ROC曲线AUC>0.82、PR曲线AUC>0.89,敏感性和阳性预测力高。结论提示TOBI指数可追踪失血性低血压期间影响CA的血流动力学和PRx变化,可能作为较无创的PRx替代指标用于CA监测。
要点
- 在猪失血性低血压模型中,DZx预测PRx的ROC曲线AUC>0.82、PR曲线AUC>0.89,敏感性和阳性预测力高。
- 失血期间CPP和CBF分别平均下降54.2%和28.3%,而dz增加277%,dz与MAP、ICP、CPP、CBF高度相关(r分别为-0.823、-0.723、-0.813、-0.726,p<0.0001)。
- TOBI通过闭合眼睑上的心电图电极记录,施加0.4 mA交流电,dz为呼吸诱导阻抗变化幅度,DZx为dz与MAP的移动Pearson相关。
- 该研究为动物实验,TOBI作为PRx无创替代指标的价值尚需临床验证。
适用人群与场景
- Yorkshire猪,通过控制性失血(25-35分钟内去除总血量的30-40%)诱导低血压(目标MAP约35 mmHg,呼气末二氧化碳>28 mmHg)以扰动脑自动调节。
诊断标准与关键阈值
- 原文未提及
处置流程与药物剂量
- 原文未提及
红旗征与不能漏的情况
- 原文未提及
研究设计与关键结果
- 研究类型:动物实验(猪模型);样本量与中心数:原文未提及;人群:Yorkshire猪;干预:控制性失血诱导低血压;对照:无独立对照组,比较TOBI指数与PRx;主要终点结果:DZx预测PRx的ROC曲线AUC>0.82、PR曲线AUC>0.89,敏感性和阳性预测力高;关键次要终点:dz与MAP、ICP、CPP、CBF高度相关(r=-0.823、-0.723、-0.813、-0.726,p<0.0001),失血期间CPP和CBF分别平均下
证据类型、等级与局限
- 证据类型:动物实验(猪模型);证据等级或推荐强度:原文未提及;局限:动物模型,样本量未提及,需临床验证。
对床旁实践的改变
- 在急诊/ICU中,TOBI可能作为无创替代PRx评估脑自动调节的候选技术,但当前证据仅来自猪失血性低血压模型,不能改变现有临床实践;适用人群与不适用人群原文未提及;常见陷阱:不能将动物实验中的预测性能直接外推至临床决策阈值。
指南或共识出处
- 原文未提及
以上提炼依据论文摘要(全文未开放获取,或许可不允许翻译转载);全文请点「阅读原文」。
英文原文(摘要)· 点击展开
BACKGROUND: Cerebrovascular autoregulation (CA) is a protective mechanism that enables the cerebral vasculature to automodulate tone in response to changes in cerebral perfusion pressure to ensure constant levels of cerebral blood flow (CBF) and oxygen delivery. CA can be impaired after neurological injury and contributes to secondary brain injury. In this study, we report novel impedance indices using trans-ocular brain impedance (TOBI) during controlled systemic hemorrhage and hypotension to assess CA in comparison with pressure reactivity index (PRx).
METHODS: Yorkshire swine were instrumented to record intracranial pressure (ICP), mean arterial pressure (MAP), and CBF. TOBI was recorded using electrocardiographic electrodes placed on the closed eyelids. Impedance changes (dz) were recorded in response to introducing an alternating current (0.4 mA) through the electrodes. MAP, ICP, and CBF were also measured. Animals were subjected to a controlled hemorrhage to remove 30-40% of each animal's total blood volume over 25-35 min. Hemorrhage was titrated to reach an MAP of approximately 35 mm Hg and end-tidal carbon dioxide above 28 mm Hg. PRx was calculated as a moving Pearson correlation between MAP and ICP. TOBI indices were calculated as the amplitude of the respiratory-induced changes in dz. DZx was calculated as a moving Pearson correlation between dz and MAP. TOBI indices (dz and DZx) were compared with hemodynamic indicators and PRx.
RESULTS: dz was shown to be highly correlated with MAP, ICP, cerebral perfusion pressure, and CBF (r = - 0.823, - 0.723, - 0.813, and - 0.726), respectively (p < 0.0001). During hemorrhage, cerebral perfusion pressure and CBF had a mean percent decrease (standard deviation) from baseline of - 54.2% (12.5%) and - 28.3% (14.7%), respectively, whereas dz increased by 277% (268%). Receiver operator characteristics and precision-recall curves demonstrated high predictive performance of DZx when compared with PRx with an area under the curve above 0.82 and 0.89 for receiver operator characteristic and precision-recall curves, respectively, with high sensitivity and positive predictive power.
CONCLUSIONS: TOBI indices appear to track changes in PRx and hemodynamics that affect CA during hemorrhage-induced hypotension. TOBI may offer a suitable, less invasive surrogate to PRx for monitoring and assessing CA.
参考来源
- Tiba MH, McCracken BM, Leander DC, et al. Trans-Ocular Brain Impedance Indices Predict Pressure Reactivity Index Changes in a Porcine Model of Hypotension and Cerebral Autoregulation Perturbation. Neurocrit Care. 2021. PMID: 34244920. doi:10.1007/s12028-021-01272-7
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。