文献速递创伤与烧伤重症综合管理与镇静镇痛

创伤后细胞外囊泡相关促凝活性在最初3小时最高,此后显著下降:一项前瞻性观察性初步研究

Extracellular vesicle-associated procoagulant activity is highest the first 3 hours after trauma and thereafter declines substantially: A prospective observational pilot study.
PubMed 文献 · J Trauma Acute Care Surg · 2021-01-01
一句话结论创伤患者伤后最初3小时EV相关促凝活性最高,7–12小时内凝血酶生成恢复正常,该活性与损伤严重度和不良预后相关。

该前瞻性观察性初步研究纳入33例便利招募的创伤患者,在创伤中心入院时及之后2、4、6、8小时采血,检测分离EV的凝血酶生成和PS暴露EV的促凝活性。结果显示EV相关促凝活性在伤后最初3小时最高,EV相关凝血酶生成在伤后7–12小时内恢复正常,PS暴露EV促凝活性降至略高于健康志愿者水平。入院时EV相关促凝活性升高与更高的NISS、更低的入院碱剩余、更高的入院INR、延长的入院APTT、更高的第0天SOFA评分和更少的无呼吸机天数相关。

要点

  • 创伤患者EV相关促凝活性在伤后最初3小时最高,随后下降,EV相关凝血酶生成在7–12小时内恢复正常。
  • 入院时EV相关促凝活性升高与更高NISS、更低碱剩余、更高INR、延长APTT、更高第0天SOFA评分和更少无呼吸机天数相关。
  • PS暴露EV促凝活性下降后仍略高于健康志愿者水平。
  • 该研究为前瞻性观察性初步研究,样本量33例,证据等级为预后/流行病学level V。
  • EV在创伤早期止血中可能起作用,但其在创伤诱导性凝血病和创伤后血栓形成中的作用需考虑这种时间模式进一步研究。

适用人群与场景

  • 便利招募的33例创伤患者,在创伤中心入院时及伤后2、4、6、8小时采集枸橼酸化血浆样本。

诊断标准与关键阈值

  • 原文未提及

处置流程与药物剂量

  • 原文未提及

红旗征与不能漏的情况

  • 原文未提及红旗征或需要立刻处理的情况。

研究设计与关键结果

  • 研究类型为前瞻性观察性初步研究,样本量33例,单中心,便利招募创伤患者。
  • EV相关促凝活性在伤后最初3小时最高,EV相关凝血酶生成在伤后7–12小时内恢复正常,PS暴露EV促凝活性下降至略高于健康志愿者水平。
  • 入院时EV相关促凝活性升高与更高NISS、更低入院碱剩余、更高入院INR、延长入院APTT、更高第0天SOFA评分和更少无呼吸机天数相关。

证据类型、等级与局限

  • 证据类型为前瞻性观察性初步研究,证据等级为预后/流行病学level V。
  • 局限包括样本量小(33例)、便利招募、单中心、观察性设计,原文未提及盲法或验证队列。

对床旁实践的改变

  • 该研究提示EV相关促凝活性在伤后最初3小时最高,7–12小时内凝血酶生成恢复正常,临床解读EV促凝标志物时需考虑采血时间窗。
  • 入院时EV相关促凝活性升高与损伤严重度、凝血指标异常和不良预后相关,但为观察性关联,不能作为决策阈值。
  • 原文未提及改变具体治疗或药物使用的推荐。

指南或共识出处

  • 原文未提及

以上提炼依据论文摘要(全文未开放获取,或许可不允许翻译转载);全文请点「阅读原文」。

英文原文(摘要)· 点击展开

BACKGROUND: Trauma patients have high concentrations of circulating extracellular vesicles (EVs) following injury, but the functional role of EVs in this setting is only partly deciphered. We aimed to describe in detail EV-associated procoagulant activity in individual trauma patients during the first 12 hours after injury to explore their putative function and relate findings to relevant trauma characteristics and outcome.

METHODS: In a prospective observational study of 33 convenience recruited trauma patients, citrated plasma samples were obtained at trauma center admission and 2, 4, 6, and 8 hours thereafter. We measured thrombin generation from isolated EVs and the procoagulant activity of phosphatidylserine (PS)-exposing EVs. Correlation and multivariable linear regression analyses were used to explore associations between EV-associated procoagulant activity and trauma characteristics as well as outcome measures.

RESULTS: EV-associated procoagulant activity was highest in the first 3 hours after injury. EV-associated thrombin generation normalized within 7 to 12 hours of injury, whereas the procoagulant activity of PS-exposing EVs declined to a level right above that of healthy volunteers. Increased EV-associated procoagulant activity at admission was associated with higher New Injury Severity Score, lower admission base excess, higher admission international normalized ratio, prolonged admission activated partial thromboplastin time, higher Sequential Organ Failure Assessment score at day 0, and fewer ventilator-free days.

CONCLUSION: Our data suggest that EVs have a transient hypercoagulable function and may play a role in the early phase of hemostasis after injury. The role of EVs in trauma-induced coagulopathy and posttraumatic thrombosis should be studied bearing in mind this novel temporal pattern.

LEVEL OF EVIDENCE: Prognostic/epidemiologic, level V.

来源:J Trauma Acute Care Surg,查看原文。版权归原作者所有。

参考来源

  1. Rognes IN, Hellum M, Ottestad W, et al. Extracellular vesicle-associated procoagulant activity is highest the first 3 hours after trauma and thereafter declines substantially: A prospective observational pilot study. J Trauma Acute Care Surg. 2021. PMID: 34225342. doi:10.1097/TA.0000000000003333

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。