重型颅脑创伤后第一周动脉血二氧化碳分压的管理:CENTER-TBI研究结果
本文为CENTER-TBI前瞻性多中心观察性队列研究的二次分析,纳入1100例重型TBI患者,共11791次PaCO2测量(5931个日最低值和5860个日最高值)。第一周平均PaCO2为38.9±5.2 mmHg,平均最低PaCO2为35.2±5.3 mmHg;ICP监测组日最低PaCO2显著更低(34.5 vs 36.7 mmHg,p<0.001),颅内高压患者日PaCO2谷值也更低(33.8 vs 35.7 mmHg,p<0.001),且中心间异质性明显。在更频繁使用深度过度通气(PaCO2<30 mmHg)的中心管理并未增加6个月死亡率(OR=1.06,95%CI 0.77-1.45,p=0.7166)或不良神经结局(OR=1.12,95%CI 0.90-1.38,p=0.3138)。
要点
- 重型TBI第一周平均PaCO2为38.9±5.2 mmHg,平均日最低PaCO2为35.2±5.3 mmHg,整体通气管理接近正常碳酸血症。
- ICP监测组日最低PaCO2显著低于无ICP监测组(34.5 vs 36.7 mmHg,p<0.001),颅内高压患者日PaCO2谷值亦更低(33.8 vs 35.7 mmHg,p<0.001)。
- 各中心间PaCO2管理异质性明显,提示缺乏统一通气目标。
- 在更频繁使用深度过度通气(PaCO2<30 mmHg)的中心管理,6个月死亡率(OR=1.06,95%CI 0.77-1.45)和不良神经结局(OR=1.12,95%CI 0.90-1.38)均未显著增加。
- 该研究为观察性分析,深度过度通气与结局的关联不能等同于因果推荐。
适用人群与场景
- 重型颅脑创伤(TBI)患者,纳入CENTER-TBI前瞻性多中心观察性队列,分析ICU第一周内PaCO2管理。
诊断标准与关键阈值
- 深度过度通气定义为PaCO2<30 mmHg。
- 颅内高压:原文提及按有无颅内高压分组,但未给出具体ICP阈值。
处置流程与药物剂量
- 原文未提及
红旗征与不能漏的情况
- 原文未提及
研究设计与关键结果
- 研究类型:CENTER-TBI多中心前瞻性观察性队列研究的二次分析;样本量1100例,共11791次PaCO2测量(5931个日最低值、5860个日最高值)。
- 第一周平均PaCO2为38.9±5.2 mmHg,平均最低PaCO2为35.2±5.3 mmHg。
- ICP监测组日最低PaCO2显著低于无ICP监测组(34.5 vs 36.7 mmHg,p<0.001);颅内高压患者日PaCO2谷值低于无颅内高压者(33.8 vs 35.7 mmHg,p<0.001)。
- 中心间PaCO2管理异质性明显。
- 在更频繁使用深度过度通气(PaCO2<30 mmHg)的中心管理,6个月死亡率无显著增加(OR=1.06,95%CI 0.77-1.45,p=0.7166),不良神经结局无显著增加(OR=1.12,95%CI 0.90-1.38,p=0.3138)。
证据类型、等级与局限
- 证据类型:多中心前瞻性观察性队列研究的二次分析;原文未给出证据等级或推荐强度。
- 局限:为观察性研究,中心层面过度通气使用频率与结局的关联可能受混杂影响,不能推断因果;原文未报告其他局限。
对床旁实践的改变
- 原文提示各中心PaCO2管理差异大,ICP监测和颅内高压患者PaCO2常更低,但中心层面更频繁使用深度过度通气(PaCO2<30 mmHg)未显示与6个月死亡或不良神经结局相关,不能据此常规推荐或禁止深度过度通气。
- 原文未给出适用或不适用人群的具体建议,临床决策仍需结合个体情况。
指南或共识出处
- CENTER-TBI研究(Intensive Care Med),原文未提及具体指南或共识名称。
以上提炼依据论文摘要(全文未开放获取,或许可不允许翻译转载);全文请点「阅读原文」。
英文原文(摘要)· 点击展开
PURPOSE: To describe the management of arterial partial pressure of carbon dioxide (PaCO2) in severe traumatic brain-injured (TBI) patients, and the optimal target of PaCO2 in patients with high intracranial pressure (ICP).
METHODS: Secondary analysis of CENTER-TBI, a multicentre, prospective, observational, cohort study. The primary aim was to describe current practice in PaCO2 management during the first week of intensive care unit (ICU) after TBI, focusing on the lowest PaCO2 values. We also assessed PaCO2 management in patients with and without ICP monitoring (ICPm), and with and without intracranial hypertension. We evaluated the effect of profound hyperventilation (defined as PaCO2 < 30 mmHg) on long-term outcome.
RESULTS: We included 1100 patients, with a total of 11,791 measurements of PaCO2 (5931 lowest and 5860 highest daily values). The mean (± SD) PaCO2 was 38.9 (± 5.2) mmHg, and the mean minimum PaCO2 was 35.2 (± 5.3) mmHg. Mean daily minimum PaCO2 values were significantly lower in the ICPm group (34.5 vs 36.7 mmHg, p < 0.001). Daily PaCO2 nadir was lower in patients with intracranial hypertension (33.8 vs 35.7 mmHg, p < 0.001). Considerable heterogeneity was observed between centers. Management in a centre using profound hyperventilation (HV) more frequently was not associated with increased 6 months mortality (OR = 1.06, 95% CI = 0.77-1.45, p value = 0.7166), or unfavourable neurological outcome (OR 1.12, 95% CI = 0.90-1.38, p value = 0.3138).
CONCLUSIONS: Ventilation is manipulated differently among centers and in response to intracranial dynamics. PaCO2 tends to be lower in patients with ICP monitoring, especially if ICP is increased. Being in a centre which more frequently uses profound hyperventilation does not affect patient outcomes.
参考来源
- Citerio G, Robba C, Rebora P, et al. Management of arterial partial pressure of carbon dioxide in the first week after traumatic brain injury: results from the CENTER-TBI study. Intensive Care Med. 2021. PMID: 34302517. doi:10.1007/s00134-021-06470-7
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。