一级创伤中心eFAST检查错误:一项回顾性队列研究
该研究为单中心回顾性队列,分析城市学术型一级创伤中心创伤激活患者的6年eFAST质控数据。共4860次eFAST检查,1450次(29.8%)因未记录、技术受限或不完整(缺图像)被排除,剩余3410次中真阳性180次(5.27%)、真阴性3128次(91.7%)、假阳性27次(0.79%)、假阴性75次(2.19%);经排除无CT或实时纸质记录一致者后,最终假阳性12次、假阴性42次。最常见错误来源为盆腔积液、双线征、心包脂肪垫和胸部eFAST部分。eFAST整体准确,但记录质量与技术完整性是质控关键。
要点
- 在创伤激活患者中,eFAST假阳性率0.79%、假阴性率2.19%,总体准确率高。
- 29.8%(1450/4860)的eFAST检查未记录、技术受限或不完整(缺图像),是质控主要问题。
- 最常见错误来源:盆腔积液、双线征、心包脂肪垫、胸部eFAST部分。
- 最终确认的假阳性12例、假阴性42例(经排除无CT或实时记录一致者后)。
- 研究为单中心回顾性队列,仅纳入与CT比较的假阳性/假阴性检查,不能推及所有eFAST。
适用人群与场景
- 城市学术型一级创伤中心接受创伤激活评估的患者。
- 仅纳入eFAST与CT比较被判定为假阳性或假阴性的检查;未记录、技术受限或不完整(缺图像)的检查被排除分析。
诊断标准与关键阈值
- 以CT影像为参考标准判定eFAST真阳性、真阴性、假阳性、假阴性。
- 原文未提及eFAST操作的具体诊断标准或阈值。
处置流程与药物剂量
- 原文未提及
红旗征与不能漏的情况
- 原文未提及
研究设计与关键结果
- 研究类型:单中心、观察性、回顾性队列,分析6年eFAST质控数据。
- 样本量:4860次eFAST检查;1450次(29.8%)因未记录、技术受限或不完整(缺图像)被排除,剩余3410次分析。
- 在3410次中:真阳性180次(5.27%)、真阴性3128次(91.7%)、假阳性27次(0.79%)、假阴性75次(2.19%)。
- 排除无CT或实时纸质记录一致者后,最终假阳性12次、假阴性42次。
- 最常见错误来源:盆腔积液、双线征、心包脂肪垫、胸部eFAST部分。
- 结论:eFAST在创伤激活患者中高度准确,但记录不全和技术受限/不完整占29.8%。
证据类型、等级与局限
- 证据类型:单中心回顾性队列研究。
- 局限:单中心、回顾性设计;仅分析假阳性/假阴性检查,未评估所有eFAST;部分检查因无CT或记录不一致被排除。
对床旁实践的改变
- eFAST判读时需特别关注盆腔积液、双线征、心包脂肪垫及胸部部分,这些是常见错误来源。
- 应加强eFAST记录完整性和图像留存,避免未记录或技术受限检查影响质控。
- 本研究不能改变eFAST作为创伤激活患者初始评估工具的地位,但提示需结合CT确认不明确或阳性发现。
指南或共识出处
- 原文未提及
以上提炼依据论文摘要(全文未开放获取,或许可不允许翻译转载);全文请点「阅读原文」。
英文原文(摘要)· 点击展开
OBJECTIVES: Extended Focused Assessment with Sonography for Trauma (eFAST) ultrasound exams are central to the care of the unstable trauma patient. We examined six years of eFAST quality assurance data to identify the most common reasons for false positive and false negative eFAST exams.
METHODS: This was an observational, retrospective cohort study of trauma activation patients evaluated in an urban, academic Level 1 trauma center. All eFAST exams that were identified as false positive or false negative exams compared with computed tomography (CT) imaging were included.
RESULTS: 4860 eFAST exams were performed on trauma patients. 1450 (29.8%) were undocumented, technically limited, or incomplete (missing images). Of the 3410 remaining exams, 180 (5.27%) were true positive and 3128 (91.7%) were true negative. 27 (0.79%) exams were identified as false positive and 75 (2.19%) were identified as false negative. Of the false positive scans, 7 had no CT scan and 8 had correct real-time trauma paper documentation of eFAST exam results when compared to CT and were excluded, leaving 12 false positive scans. Of the false negative scans, 11 were excluded for concordant documentation in real-time trauma room paper documentation, 20 were excluded for no CT scan, and 2 were excluded as incomplete, leaving 42 false negative scans. Pelvic fluid, double-line sign, pericardial fat pad, and the thoracic portion of the eFAST exam were the most common source of errors.
CONCLUSION: The eFAST exams in trauma activation patients are highly accurate. Unfortunately poor documentation and technically limited/incomplete studies represent 29.8% of our eFAST exams. Pelvic fluid, double-line sign, pericardial fat pad, and the thoracic portion of the eFAST exam are the most common source of errors.
参考来源
- Khosravian K, Boniface K, Dearing E, et al. eFAST exam errors at a level 1 trauma center: A retrospective cohort study. Am J Emerg Med. 2021. PMID: 34325179. doi:10.1016/j.ajem.2021.07.036
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。