文献速递呼吸衰竭与机械通气重症综合管理与镇静镇痛

压力支持通气下双触发异步呼吸时的摆动气流容积:一项前瞻性生理学研究

[Pendelluft volume during double-triggered asynchronous breaths under pressure support ventilation: a prospective physiological study].
PubMed 文献 · Zhonghua Wei Zhong Bing Ji Jiu Yi Xue · 2021-01-01
一句话结论PSV下双触发呼吸时摆动气流容积显著增加,双触发越频繁摆动现象越严重,正常呼吸摆动容积和呼吸频率与双触发严重程度相关。

该前瞻性观察研究纳入北京天坛医院ICU术后接受有创机械通气PSV模式的患者40例,用电阻抗断层成像(EIT)同步采集并离线分析气道压-时间、流速-时间及全局/区域阻抗-时间曲线,测量双触发呼吸(首次触发呼吸、双触发呼吸、双触发后即刻呼吸)及正常呼吸的摆动气流容积。与正常呼吸相比,首次触发呼吸、双触发呼吸及双触发后正常呼吸的摆动容积均显著升高。严重双触发组(≥1次/min)正常呼吸及双触发呼吸的摆动容积、呼吸频率均显著高于非严重组。

要点

  • PSV模式下双触发呼吸时摆动气流容积显著高于正常呼吸:双触发呼吸8.3(3.6, 13.2)mL vs 正常呼吸1.4(0.7, 2.8)mL,P<0.05。
  • 双触发越频繁摆动现象越严重:严重双触发组(≥1次/min)双触发呼吸摆动容积8.5(3.9, 13.4)mL vs 非严重组2.0(0.6, 9.1)mL,P=0.008。
  • 严重双触发组正常呼吸摆动容积亦更高[1.8(0.9, 3.2)mL vs 1.1(0.5, 2.1)mL,P<0.001],呼吸频率更快(20.9±3.5 vs 15.2±3.7次/min,P<0.001)。
  • 双触发识别一致性高:观察者间Kappa 0.964(95%CI 0.946-0.982)。
  • 两组其他呼吸力学参数及主要临床结局无显著差异。

适用人群与场景

  • 北京天坛医院重症医学科2019年4月1日至2020年8月31日收治的术后患者,接受有创机械通气且为PSV模式。

诊断标准与关键阈值

  • 双触发呼吸由经过培训的研究者识别。
  • 根据双触发频率分为严重双触发组(≥1次/min)与非严重双触发组。
  • 摆动气流容积定义为吸气开始时肺内气体异常运动的容积,通过EIT区域阻抗变化测量。

处置流程与药物剂量

  • 原文未提及

红旗征与不能漏的情况

  • 原文未提及

研究设计与关键结果

  • 双触发识别观察者间Kappa 0.964(95%CI 0.946-0.982)。
  • 222次双触发呼吸中7次(3.2%)无法测量摆动容积但EIT显示双触发吸气开始时存在区域阻抗反向变化即摆动现象;最终215次双触发呼吸测量了摆动容积;另选400次正常呼吸(每例随机10次)为对照。
  • 与正常呼吸相比,首次触发呼吸、双触发呼吸及双触发后正常呼吸的摆动容积均显著升高[mL:3.0(1.4, 6.4)、8.3(3.6, 13.2)、4.3(1.9, 9.1)vs 1.4(0.7, 2.8),均P<0.05]。
  • 严重双触发组正常呼吸及双触发呼吸摆动容积均显著高于非严重组[mL:1.8(0.9, 3.2)vs 1.1(0.5, 2.1),P<0.001;8.5(3.9, 13.4)vs 2.0(0.6, 9.1),P=0.008]。
  • 严重双触发组呼吸频率显著高于非严重组(次/min:20.9±3.5 vs 15.2±3.7,P<0.001)。
  • 两组其他呼吸力学参数及主要临床结局无显著差异。

证据类型、等级与局限

  • 证据类型:前瞻性观察性生理学研究(单中心、样本量40例)。
  • 局限:单中心、观察性设计、样本量小;摆动容积在3.2%双触发呼吸中无法测量;原文未提及盲法及前瞻性验证情况。

对床旁实践的改变

  • PSV模式下双触发呼吸与摆动气流容积增加相关,双触发越频繁摆动现象越严重,提示床旁识别双触发对评估肺内气体异常运动有潜在意义。
  • 正常呼吸摆动容积较高及呼吸频率较快与双触发严重程度相关,原文未给出可用于决策的阈值。
  • 原文未提及基于摆动容积或双触发频率的具体干预措施及适用/不适用人群。

指南或共识出处

  • 原文未提及

以上提炼依据论文摘要(全文未开放获取,或许可不允许翻译转载);全文请点「阅读原文」。

英文原文(摘要)· 点击展开

OBJECTIVE: To investigate the relationship between double-triggering and abnormal movement of air in the lungs (pendelluft phenomenon) under pressure support ventilation (PSV).

METHODS: A prospective observational study was conducted, postoperative patients admitted to department of critical care medicine of Beijing Tiantan Hospital, Capital Medical University from April 1, 2019 to August 31, 2020 and received invasive mechanical ventilation with PSV mode were enrolled. Electrical impedance tomography (EIT) monitoring was performed. Airway pressure-time, flow-time, global and regional impedance-time curves were synchronously collected and analyzed offline. The volume of abnormal movement of air in the lungs at the beginning of inspiration was measured and defined as pendelluft volume. Double-triggered breaths were identified by trained researchers. Pendelluft volume during double-triggering was measured including the first triggered breath, the double-triggered breath, and the breath immediately following the double-triggered breath. Pendelluft volume was also measured for normal breath during the study. According to the frequency of double-triggering, patients were divided into severe (≥ 1 time/min) and non-severe double-triggering group. Pendelluft volume, parameters of respiratory mechanics, and clinical outcomes between the two groups were compared.

RESULTS: In 40 enrolled patients, a total of 9 711 breaths [(243±63) breaths/patient] were collected and analyzed, among which 222 breaths (2.3%) were identified as double-triggering. The Kappa of interobserver reliability to detect double-triggering was 0.964 [95% confidence interval (95%CI) was 0.946-0.982]. In 222 double-triggered breaths, pendelluft volume could not be measured in 7 breaths (3.2%), but the pendelluft phenomenon did exist as shown by opposite regional impedance change at the beginning of double-triggered inspiration. Finally, pendelluft volume was measured in 215 double-triggered breaths. Meanwhile, 400 normal breaths (10 normal breaths randomly selected for each patient) were identified as control. Compared with normal breath, pendelluft volume significantly increased in the first breath, the double-triggered breath, and the following normal breath [mL: 3.0 (1.4, 6.4), 8.3 (3.6, 13.2), 4.3 (1.9, 9.1) vs. 1.4 (0.7, 2.8), all P < 0.05]. Patients in severe double-triggering, pendelluft volume of normal breath and double-triggered breath were significantly higher than those in non-severe double-triggering group [mL: 1.8 (0.9, 3.2) vs. 1.1 (0.5, 2.1), P < 0.001; 8.5 (3.9, 13.4) vs. 2.0 (0.6, 9.1), P = 0.008]. Patients in severe double-triggering group had significantly higher respiratory rate than that in the non-severe double-triggering group (breaths/min: 20.9±3.5 vs. 15.2±3.7, P < 0.001). There were no significant differences in other respiratory mechanics parameters and main clinical outcomes between the two groups.

CONCLUSIONS: During PSV, the abnormal movement of air in the lungs (pendelluft phenomenon) was more likely to occur in double-triggering especially in double-triggered breath. The more frequent the double-triggering occurred, the more serious the pendelluft phenomenon was. A higher pendelluft volume of normal breath and a higher respiratory rate were related to severity of double-triggering.

来源:Zhonghua Wei Zhong Bing Ji Jiu Yi Xue,查看原文。版权归原作者所有。

参考来源

  1. Zhou Y, Luo X, Wang Y, et al. [Pendelluft volume during double-triggered asynchronous breaths under pressure support ventilation: a prospective physiological study]. Zhonghua Wei Zhong Bing Ji Jiu Yi Xue. 2021. PMID: 34296686. doi:10.3760/cma.j.cn121430-20210115-00064

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。