文献速递复苏、休克与脓毒症

同步在线与面对面心肺复苏培训对胸外按压质量的影响:一项模拟人随机预试验

Effect of synchronous online vs. face-to-face cardiopulmonary resuscitation training on chest compression quality: A pilot randomized manikin study.
PubMed 文献 · Am J Emerg Med · 2021-07-09
一句话结论同步在线联合视听反馈装置培训的胸外按压质量与面对面培训相近,可作为替代方案。

该随机模拟人预试验纳入118名四年级医学生,比较同步在线(腾讯会议直播)与面对面心肺复苏培训对胸外按压质量的影响,并进一步随机分为有无视听反馈装置(AVF)亚组。结果显示同步在线与面对面培训组间按压质量差异很小;面对面培训中AVF组按压深度、合适深度比例、按压频率及合适频率比例显著更优;同步在线培训中AVF对按压频率影响小、合适频率比例有升高但无统计学意义。结论认为同步在线联合AVF装置可作为面对面胸外按压培训的潜在替代方案。

要点

  • 同步在线培训组与面对面培训组胸外按压质量差异很小,无统计学显著性。
  • 面对面培训中,使用AVF装置的组按压深度、合适深度比例、按压频率及合适频率比例显著优于无AVF组。
  • 面对面培训使用AVF组合适按压频率比例高于同步在线使用AVF组(p=0.045)。
  • 同步在线培训中,AVF装置对按压频率影响小(p=0.851),合适频率比例升高但无统计学意义(p=0.178)。
  • 同步在线联合AVF装置可作为面对面胸外按压培训的潜在替代方案。

适用人群与场景

  • 四年级医学生,共118名,参与模拟人心肺复苏培训研究。
  • 排除标准原文未提及。

诊断标准与关键阈值

  • 胸外按压质量指标:按压深度、按压频率、合适深度比例(50-60 mm)、合适频率比例(100-120/min)、正确手位置百分比、完全胸廓回弹百分比。
  • 模拟心脏骤停场景下进行2分钟连续胸外按压,且不使用视听反馈装置。

处置流程与药物剂量

  • 第一步:面对面培训组由导师现场进行45分钟心肺复苏培训并提供反馈指导。
  • 第二步:同步在线培训组通过腾讯会议直播接受在线讲座培训。
  • 第三步:培训后参与者在不使用视听反馈装置的情况下进行2分钟连续胸外按压。
  • 药物剂量原文未提及。

红旗征与不能漏的情况

  • 原文未提及

研究设计与关键结果

  • 研究类型:随机模拟人预试验;样本量:118名四年级医学生;单中心(原文未明确中心数)。
  • 干预与对照:同步在线培训 vs 面对面培训,并进一步随机分为有无AVF装置亚组(TF n=30,TN n=29,FF n=30,FN n=29)。
  • 主要终点结果:同步在线与面对面培训组间胸外按压质量差异很小,无统计学显著性差异。
  • 关键次要终点:面对面培训中AVF组按压深度、合适深度比例、按压频率及合适频率比例显著优于无AVF组;FF组合适按压频率比例高于TF组(p=0.045)。
  • 不良事件原文未提及。

证据类型、等级与局限

  • 证据类型:随机模拟人预试验。
  • 证据等级或推荐强度原文未提及。
  • 局限:预试验、样本量小、单中心(原文未明确)、模拟人模型、医学生人群,结论需进一步验证。

对床旁实践的改变

  • 同步在线联合AVF装置培训可作为面对面胸外按压培训的潜在替代方案,适用于医学生 bystander CPR 培训。
  • 面对面培训中推荐使用AVF装置以改善按压深度和频率。
  • 同步在线培训中AVF装置对按压频率改善有限,需注意。
  • 不适用人群和常见陷阱原文未提及。

指南或共识出处

  • 原文未提及

以上提炼依据论文摘要(全文未开放获取,或许可不允许翻译转载);全文请点「阅读原文」。

英文原文(摘要)· 点击展开

OBJECTIVES: The aim of the study was to compare the effect of synchronous online and face-to-face cardiopulmonary resuscitation (CPR) training on chest compressions quality in a manikin model.

METHODS: A total of 118 fourth-year medical students participated in this study. The participants were divided into two groups: the online synchronous teaching group and the face-to-face group. Then, the participants were further randomly distributed to 1 of 2 feedback groups: online synchronous teaching and training with feedback devices (TF, n = 30) or without feedback devices (TN, n = 29) and face-to-face teaching and training with feedback devices (FF, n = 30) or without feedback devices (FN, n = 29). In the FN group and FF group, instructors delivered a 45-min CPR training program and gave feedback and guidance during training on site. In the TN group and TF group, the participants were trained with an online lecture via Tencent Meeting live broadcasting. Finally, participants performed a 2-min continuous chest compression (CC) during a simulated cardiopulmonary arrest scene without the audiovisual feedback (AVF) device. The outcome measures included CC depth, CC rate, proportions of appropriate depth (50-60 mm) and CC rate (100-120/min), percentage of correct hand location position, and percentage of complete chest recoil.

RESULTS: There was little difference in the CC quality between the synchronous online training groups and the face-to-face training groups. There was no statistically significant difference in CC quality between the TN group and FN group. There were also no statistically significant differences between the TF and FF groups in terms of correct hand position, CC depth, appropriate CC depth, complete chest recoil or CC rate. However, the FF group had a higher appropriate CC rate than the TF group (p = 0.045). In the face-to-face training groups, the AVF device group had a significantly greater CC depth, appropriate CC depth, CC rate, and appropriate CC rate. However, there was a lack of statistically significant differences in terms of correct hand position (p = 0.191) and appropriate CC depth (p = 0.123). In the synchronous online training groups, the AVF device had little effect on the CC rate (p = 0.851) and increased the appropriate CC rate, but the difference was not statistically significant (p = 0.178).

CONCLUSIONS: Synchronous online training with an AVF device would be a potential alternative approach to face-to-face chest compression training. Synchronous online training with AVF devices seems to be a suitable replacement for face-to-face training to offer adequate bystander CPR chest compression training.

来源:Am J Emerg Med,查看原文。版权归原作者所有。

参考来源

  1. Lin L, Ni S, Cheng J, et al. Effect of synchronous online vs. face-to-face cardiopulmonary resuscitation training on chest compression quality: A pilot randomized manikin study. Am J Emerg Med. 2021. PMID: 34314941. doi:10.1016/j.ajem.2021.07.009

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。