早期高氧血症对符合Sepsis-3标准的机械通气脓毒性休克患者死亡率的影响:MIMIC-III数据库分析
两组ICU住院时长无差异。结论提示早期高氧血症对该人群死亡率无独立影响。
要点
- 研究人群为符合Sepsis-3标准、机械通气的脓毒性休克患者,比较入ICU首个24小时TWA-PaO2 70–120 mmHg与>120 mmHg两组。
- 两组ICU住院时长无差异(8.0 vs 8.4天,P=0.82)。
- 该回顾性队列结果不支持将早期高氧血症作为独立危险因素用于床旁决策。
适用人群与场景
- 符合Sepsis-3标准的脓毒性休克患者,接受机械通气,入住ICU。
- 数据来源为MIMIC-III数据库记录的ICU入院,属回顾性队列。
诊断标准与关键阈值
- 脓毒性休克诊断依据Sepsis-3标准(原文未列出具体条件与界值)。
- 氧暴露分组依据入ICU首个24小时平均PaO2(TWA-PaO2):正常氧组70–120 mmHg,高氧组>120 mmHg。
处置流程与药物剂量
- 原文未提及
红旗征与不能漏的情况
- 原文未提及
研究设计与关键结果
- 正常氧组中位TWA-PaO2为99.1(88.9–107.6)mmHg,高氧组为151.5(133.6–180.2)mmHg。
- 次要终点ICU住院时长两组无差异(8.0 vs 8.4天,P=0.82)。
证据类型、等级与局限
- 证据类型:回顾性队列研究(基于MIMIC-III数据库分析)。
对床旁实践的改变
- 该研究结果不支持仅依据入ICU首个24小时TWA-PaO2>120 mmHg来预判脓毒性休克机械通气患者的ICU死亡风险。
- 单因素分析中高氧组死亡率较低,但多因素分析后无差异,提示不应将单因素结果直接用于床旁决策。
- 原文未提及对氧疗目标或FiO2调整的具体推荐,不能据此改变氧疗策略。
指南或共识出处
- 原文未提及
以上提炼依据论文摘要(全文未开放获取,或许可不允许翻译转载);全文请点「阅读原文」。
英文原文(摘要)· 点击展开
BACKGROUND AND IMPORTANCE: Hyperoxemia may be associated with increased mortality in emergency room or ICU patients. However, its effect during septic shock is still debated.
OBJECTIVE: To evaluate the effect of hyperoxemia on ICU mortality, during the first 24 h of ICU stay, in mechanically ventilated patients with septic shock according to SEPSIS-3 criteria.
DESIGN, SETTINGS AND PARTICIPANTS: A retrospective cohort study of ICU admissions recorded in the Medical Information Mart for Intensive Care-III, a retrospective ICU database, was performed.
INTERVENTION: Two oxygen exposures during the first 24 h were compared: average PaO2 (TWA-PaO2) between 70 and 120 mmHg in the normoxemia group and above 120 mmHg in the hyperoxemia group.
OUTCOME MEASURES AND ANALYSIS: The primary outcome was mortality during ICU stay.
MAIN RESULTS: Four hundred eighty-eight ICU admissions met the inclusion criteria: 214 in the normoxemia group and 274 in the hyperoxemia group. The median TWA-PaO2 was 99.1 (88.9-107.6) mmHg in the normoxemia group and 151.5 (133.6-180.2) mmHg in the hyperoxemia group. ICU mortality was lower in the hyperoxemia group than in the normoxemia group in univariate analysis [29.6 vs. 39.7%, respectively; OR 0.64 (0.44-0.93); P = 0.024], but not in multivariate analysis [OR 0.98 (0.62-1.56); P = 0.93]. There was no difference between the two groups in ICU length of stay [8.0 (4.3-15.0) vs. 8.4 (4.7-15.0) days; P = 0.82].
CONCLUSION: We did not find any impact of early hyperoxemia on mortality in this population of mechanically ventilated patients with SEPSIS-3 septic shock criteria.
参考来源
- Popoff B, Besnier E, Dureuil B, et al. Effect of early hyperoxemia on mortality in mechanically ventilated septic shock patients according to Sepsis-3 criteria: analysis of the MIMIC-III database. Eur J Emerg Med. 2021. PMID: 34285171. doi:10.1097/MEJ.0000000000000854
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。