自动瞳孔测量有助于监测心肺复苏效果并预测自主循环恢复
该研究在16头雄性家猪心脏骤停模型中,持续监测冠脉灌注压、呼气末二氧化碳、脑组织氧饱和度和颈动脉血流等传统指标,并在基线、骤停后1/4/7分钟及CPR中1/4/7分钟用自动定量瞳孔测量仪测瞳孔参数。11/16头实现ROSC。复苏成功动物的CPP、ETCO2、rSO2、CBF在CPR中显著更高,Init和End更小、%PLR更大;传统指标与瞳孔参数呈中度至良好相关(|r|=0.46-0.78,均P<0.001)。自动瞳孔测量预测ROSC的AUC为0.821-0.873,与传统指标(AUC 0.809-0.946)相当。提示自动瞳孔测量可能作为监测CPR效果和预测ROSC的替代方法,但证据仅来自动物模型。
要点
- 猪心脏骤停模型中,复苏成功组CPR期间CPP、ETCO2、rSO2、CBF显著高于未复苏组。
- 复苏成功组CPR期间Init和End减小、%PLR增大,与未复苏组相比有差异。
- Init、End、%PLR预测ROSC的AUC分别为0.821、0.873、0.821(均P<0.05)。
- 传统指标与瞳孔参数中度至良好相关(|r|=0.46-0.78,均P<0.001)。
- 证据仅来自16头猪的动物实验,不能直接外推为临床推荐。
适用人群与场景
- 16头雄性家猪心脏骤停模型,用于研究CPR监测与ROSC预测,非人类临床人群。
诊断标准与关键阈值
- 原文未提及
处置流程与药物剂量
- 原文未提及
红旗征与不能漏的情况
- 原文未提及
研究设计与关键结果
- 研究类型:动物实验(猪心脏骤停模型),样本量16头雄性家猪,单中心(原文未提及中心数)。
- 11/16头动物实现ROSC;复苏成功组CPR期间CPP、ETCO2、rSO2、CBF显著高于未复苏组。
- 复苏成功组CPR期间Init和End减小、%PLR增大,与未复苏组相比有差异。
- 传统指标与Init、End、%PLR呈中度至良好相关(|r|=0.46-0.78,均P<0.001)。
- 自动瞳孔测量预测ROSC的AUC:Init 0.821、End 0.873、%PLR 0.821(均P<0.05);传统指标AUC 0.809-0.946。
- 原文未提及关键次要终点和不良事件的具体数据。
证据类型、等级与局限
- 证据类型:动物实验(猪心脏骤停模型);原文未给出证据等级或推荐强度。
- 局限:样本量小(16头猪)、动物模型结果不能直接外推至临床、原文未提及盲法与随机化等设计细节。
对床旁实践的改变
- 原文提示自动瞳孔测量可能作为监测CPR效果和预测ROSC的替代方法,但证据仅来自猪模型,尚不能改变临床实践。
- 适用与不适用人群:原文仅纳入雄性家猪心脏骤停模型,未涉及人类适用或不适用人群。
指南或共识出处
- 原文未提及
以上提炼依据论文摘要(全文未开放获取,或许可不允许翻译转载);全文请点「阅读原文」。
英文原文(摘要)· 点击展开
BACKGROUND: We investigated the effectiveness of automated pupillometry on monitoring cardiopulmonary resuscitation (CPR) and predicting return of spontaneous circulation (ROSC) in a swine model of cardiac arrest (CA).
METHODS: Sixteen male domestic pigs were included. Traditional indices including coronary perfusion pressure (CPP), end-tidal carbon dioxide (ETCO2), regional cerebral tissue oxygen saturation (rSO2) and carotid blood flow (CBF) were continuously monitored throughout the experiment. In addition, the pupillary parameters including the initial pupil size before constriction (Init, maximum diameter), the end pupil size at peak constriction (End, minimum diameter), and percentage of change (%PLR) were measured by an automated quantitative pupillometer at baseline, at 1, 4, 7 min during CA, and at 1, 4, 7 min during CPR.
RESULTS: ROSC was achieved in 11/16 animals. The levels of CPP, ETCO2, rSO2 and CBF were significantly greater during CPR in resuscitated animals than those non-resuscitated ones. Init and End were decreased and %PLR was increased during CPR in resuscitated animals when compared with those non-resuscitated ones. There were moderate to good significant correlations between traditional indices and Init, End, and %PLR (|r| = 0.46-0.78, all P < 0.001). Furthermore, comparable performance was also achieved by automated pupillometry (AUCs of Init, End and %PLR were 0.821, 0.873 and 0.821, respectively, all P < 0.05) compared with the traditional indices (AUCs = 0.809-0.946).
CONCLUSION: The automated pupillometry may serve as an effective surrogate method to monitor cardiopulmonary resuscitation efficacy and predict ROSC in a swine model of cardiac arrest.
参考来源
- Shi L, Xu J, Wang J, et al. Automated pupillometry helps monitor the efficacy of cardiopulmonary resuscitation and predict return of spontaneous circulation. Am J Emerg Med. 2021. PMID: 34246167. doi:10.1016/j.ajem.2021.06.058
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。