电阻抗断层成像指导ARDS患者个体化PEEP与潮气量的初步可行性研究
该初步可行性研究纳入20例ARDS机械通气患者,先按ARDS Network推荐设置潮气量6 ml/kg预测体重、PEEP按低PEEP/FiO2表调整,随后每30分钟按基于电阻抗断层成像(EIT)的方案调整呼吸机参数,持续4小时。结果显示PEEP由10 [8-10] mbar升至16.5 [14-18] mbar(p=0.0001),潮气量相似(5.7±0.92 ml/kg vs 5.8±0.47 ml/kg,p=0.96);全部患者全局肺应力低于27 mbar,19/20例全局肺应变低于2.0;顺应性相似,氧合显著改善,肺泡周期减少。作者结论认为该EIT方案可实现呼吸机参数个体化而不引起全局过度膨胀。
要点
- 按EIT方案每30分钟调整一次、持续4小时,PEEP由10 [8-10] mbar升至16.5 [14-18] mbar(p=0.0001)。
- 潮气量在优化前后相似:5.7±0.92 ml/kg vs 5.8±0.47 ml/kg(p=0.96)。
- 全局肺应力全部患者低于27 mbar,全局肺应变19/20例低于2.0。
- 氧合显著改善、肺泡周期减少,呼吸系统顺应性保持相似。
- 该研究为初步可行性研究,样本量20例,结论需在更大样本中验证。
适用人群与场景
- 纳入20例急性呼吸窘迫综合征(ARDS)机械通气患者。
- 研究场景为床旁EIT监测下调整呼吸机参数。
诊断标准与关键阈值
- 以全局肺应力低于27 mbar、全局肺应变低于2.0作为评估全局过度膨胀的界值。
- 初始通气按ARDS Network推荐:潮气量6 ml/kg预测体重,PEEP按低PEEP/FiO2表调整。
处置流程与药物剂量
- 初始按ARDS Network推荐设置潮气量6 ml/kg预测体重、PEEP按低PEEP/FiO2表调整。
- 随后按基于EIT的方案每30分钟调整一次PEEP和潮气量,持续4小时。
- 调整依据为EIT衍生的可复张性、过度膨胀和肺泡周期信息。
研究设计与关键结果
- 研究类型为初步可行性研究,纳入20例ARDS患者。
- EIT优化后PEEP为16.5 [14-18] mbar,优化前为10 [8-10] mbar(p=0.0001)。
- 潮气量优化后5.7±0.92 ml/kg,优化前5.8±0.47 ml/kg(p=0.96)。
- 全局肺应力全部患者低于27 mbar;全局肺应变19/20例低于2.0。
- 呼吸系统顺应性保持相似,氧合显著改善,肺泡周期减少。
证据类型、等级与局限
- 证据类型:初步可行性研究(pilot feasibility study)。
- 试验注册:clinicaltrials.gov(NCT02703012),2016年3月9日注册。
- 局限:原文未报告局限性;本研究为初步可行性研究,样本量20例,作者结论需进一步验证。
对床旁实践的改变
- 作者认为,使用基于EIT的方案调整PEEP和潮气量可实现呼吸机参数个体化,改善氧合、减少肺泡周期而不引起全局过度膨胀。
- 该方案为每30分钟调整一次、持续4小时的EIT监测流程,需在具备EIT设备的床旁环境下实施。
- 本研究为初步可行性研究,尚不能据此将EIT方案作为ARDS常规通气策略。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
BACKGROUND: In mechanically ventilated patients with acute respiratory distress syndrome (ARDS), electrical impedance tomography (EIT) provides information on alveolar cycling and overdistension as well as assessment of recruitability at the bedside. We developed a protocol for individualization of positive end-expiratory pressure (PEEP) and tidal volume (VT) utilizing EIT-derived information on recruitability, overdistension and alveolar cycling. The aim of this study was to assess whether the EIT-based protocol allows individualization of ventilator settings without causing lung overdistension, and to evaluate its effects on respiratory system compliance, oxygenation and alveolar cycling.
METHODS: 20 patients with ARDS were included. Initially, patients were ventilated according to the recommendations of the ARDS Network with a VT of 6 ml per kg predicted body weight and PEEP adjusted according to the lower PEEP/FiO2 table. Subsequently, ventilator settings were adjusted according to the EIT-based protocol once every 30 min for a duration of 4 h. To assess global overdistension, we determined whether lung stress and strain remained below 27 mbar and 2.0, respectively.
RESULTS: Prospective optimization of mechanical ventilation with EIT led to higher PEEP levels (16.5 [14-18] mbar vs. 10 [8-10] mbar before optimization; p = 0.0001) and similar VT (5.7 ± 0.92 ml/kg vs. 5.8 ± 0.47 ml/kg before optimization; p = 0.96). Global lung stress remained below 27 mbar in all patients and global strain below 2.0 in 19 out of 20 patients. Compliance remained similar, while oxygenation was significantly improved and alveolar cycling was reduced after EIT-based optimization.
CONCLUSIONS: Adjustment of PEEP and VT using the EIT-based protocol led to individualization of ventilator settings with improved oxygenation and reduced alveolar cycling without promoting global overdistension. Trial registrationThis study was registered at clinicaltrials.gov (NCT02703012) on March 9, 2016 before including the first patient.
参考来源
- Becher T, Buchholz V, Hassel D, et al. Individualization of PEEP and tidal volume in ARDS patients with electrical impedance tomography: a pilot feasibility study. Ann Intensive Care. 2021. PMID: 34080074. doi:10.1186/s13613-021-00877-7
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。