文献速递呼吸衰竭与机械通气重症综合管理与镇静镇痛

电阻抗断层成像测量的通气血流失配可预测ARDS结局

Unmatched ventilation and perfusion measured by electrical impedance tomography predicts the outcome of ARDS.
PubMed 文献 · Crit Care · 2021-06-03
一句话结论在ARDS患者中,电阻抗断层成像(EIT)测得的通气血流失配单位百分比是非死亡者的独立预测因子(OR 1.22,95%CI 1.07-1.39,p=0.004),曲线下面积0.88。

这项前瞻性观察研究纳入50例轻度(36%)、中度(46%)和重度(18%)ARDS患者,在临床通气设置下用EIT通过5%盐水中心静脉团注法测量区域通气与血流分布。失配单位百分比(仅通气单位百分比+仅灌注单位百分比)在死亡者中显著高于存活者(32[27-47]% vs. 21[17-27]%,p<0.001),且为死亡的独立预测因子(OR 1.22,95%CI 1.07-1.39,p=0.004),ROC曲线下面积0.88(95%CI 0.79-0.97,p<0.001)。通气向腹侧区域分布高于背侧(32[27-38]% vs. 18[13-21]%,p<0.001),血流灌注则相反(28[22-38]% vs. 36[32-44]%,p<0.001)。仅灌注单位百分比越高,与背侧通气越低(r=-0.486,p<0.001)及PaO2/FiO2越低(r=-0.293,p=0.039)相关。

要点

  • 死亡者失配单位百分比为32[27-47]%,显著高于存活者的21[17-27]%(p<0.001)。
  • 失配单位百分比是死亡的独立预测因子:OR 1.22(95%CI 1.07-1.39,p=0.004),ROC曲线下面积0.88(95%CI 0.79-0.97,p<0.001)。
  • 通气向腹侧区域分布高于背侧(32[27-38]% vs. 18[13-21]%,p<0.001),血流灌注则相反(28[22-38]% vs. 36[32-44]%,p<0.001)。
  • 仅灌注单位百分比越高,与背侧通气越低(r=-0.486,p<0.001)及PaO2/FiO2越低(r=-0.293,p=0.039)相关。
  • EIT可在床旁通过5%盐水中心静脉团注法于吸气末暂停时测量区域通气与血流分布,评估通气血流失配。

适用人群与场景

  • 接受机械通气的轻度(36%)、中度(46%)、重度(18%)ARDS患者,在临床通气设置下进行研究。

诊断标准与关键阈值

  • 失配单位定义为仅通气单位百分比加上仅灌注单位百分比。

研究设计与关键结果

  • 前瞻性观察研究纳入50例轻至重度ARDS患者,在临床通气设置下用EIT测量区域通气与血流分布。
  • 死亡者失配单位百分比为32[27-47]%,存活者为21[17-27]%,死亡者显著高于存活者(p<0.001)。
  • 失配单位百分比是死亡的独立预测因子(OR 1.22,95%CI 1.07-1.39,p=0.004),ROC曲线下面积0.88(95%CI 0.79-0.97,p<0.001)。
  • 通气向腹侧区域分布为32[27-38]%,高于背侧的18[13-21]%(p<0.001);血流灌注向腹侧区域分布为28[22-38]%,低于背侧的36[32-44]%(p<0.001)。
  • 仅灌注单位百分比越高,与背侧通气越低相关(r=-0.486,p<0.001),与PaO2/FiO2越低相关(r=-0.293,p=0.039)。

证据类型、等级与局限

  • 证据类型:前瞻性观察研究;局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为,测量失配单位可识别死亡风险较高的患者,并可能指导个体化治疗。
  • EIT可在床旁评估机械通气ARDS患者的通气血流失配。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

BACKGROUND: In acute respiratory distress syndrome (ARDS), non-ventilated perfused regions coexist with non-perfused ventilated regions within lungs. The number of unmatched regions might reflect ARDS severity and affect the risk of ventilation-induced lung injury. Despite pathophysiological relevance, unmatched ventilation and perfusion are not routinely assessed at the bedside. The aims of this study were to quantify unmatched ventilation and perfusion at the bedside by electrical impedance tomography (EIT) investigating their association with mortality in patients with ARDS and to explore the effects of positive end-expiratory pressure (PEEP) on unmatched ventilation and perfusion in subgroups of patients with different ARDS severity based on PaO2/FiO2 and compliance.

METHODS: Prospective observational study in 50 patients with mild (36%), moderate (46%), and severe (18%) ARDS under clinical ventilation settings. EIT was applied to measure the regional distribution of ventilation and perfusion using central venous bolus of saline 5% during end-inspiratory pause. We defined unmatched units as the percentage of only ventilated units plus the percentage of only perfused units.

RESULTS: Percentage of unmatched units was significantly higher in non-survivors compared to survivors (32[27-47]% vs. 21[17-27]%, p < 0.001). Percentage of unmatched units was an independent predictor of mortality (OR 1.22, 95% CI 1.07-1.39, p = 0.004) with an area under the ROC curve of 0.88 (95% CI 0.79-0.97, p < 0.001). The percentage of ventilation to the ventral region of the lung was higher than the percentage of ventilation to the dorsal region (32 [27-38]% vs. 18 [13-21]%, p < 0.001), while the opposite was true for perfusion (28 [22-38]% vs. 36 [32-44]%, p < 0.001). Higher percentage of only perfused units was correlated with lower dorsal ventilation (r = - 0.486, p < 0.001) and with lower PaO2/FiO2 ratio (r = - 0.293, p = 0.039).

CONCLUSIONS: EIT allows bedside assessment of unmatched ventilation and perfusion in mechanically ventilated patients with ARDS. Measurement of unmatched units could identify patients at higher risk of death and could guide personalized treatment.

来源:Crit Care,查看原文。版权归原作者所有。

参考来源

  1. Spinelli E, Kircher M, Stender B, et al. Unmatched ventilation and perfusion measured by electrical impedance tomography predicts the outcome of ARDS. Crit Care. 2021. PMID: 34082795. doi:10.1186/s13054-021-03615-4

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。