膈肌增厚分数预测无创通气结局:一项初步生理学研究
该初步生理学研究在36个月内纳入18例急诊科新发急性呼吸衰竭并需无创通气治疗的患者,由2名经过培训的操作者在基线及无创通气1、4、12、24、48、72、96小时和/或直至停止无创通气或插管时测量DTF和呼吸频率/DTF比值。DTF评估总体重复性良好,组内相关系数(ICC)为0.82(95%CI 0.72-0.88)。预测无创通气失败的DTF截断值操作者1为<36.3%、操作者2为<37.1%(p<0.0001),呼吸频率/DTF比值截断值两操作者均为>0.6(p<0.0001)。作者认为DTF和呼吸频率/DTF比值可能均是预测新发急性呼吸衰竭患者无创通气结局的有效、可行且无创的工具。
要点
- 18例急诊科新发急性呼吸衰竭需无创通气患者中,DTF评估总体重复性良好,ICC为0.82(95%CI 0.72-0.88)。
- 预测无创通气失败的DTF截断值:操作者1为<36.3%(p<0.0001),操作者2为<37.1%(p<0.0001)。
- 预测无创通气失败的呼吸频率/DTF比值截断值两操作者均为>0.6(p<0.0001)。
- DTF和呼吸频率/DTF比值可能均是预测新发急性呼吸衰竭患者无创通气结局的有效、可行且无创的工具。
适用人群与场景
- 急诊科收治的新发急性呼吸衰竭并需要无创通气治疗的患者。
诊断标准与关键阈值
- 预测无创通气失败的DTF截断值:操作者1为<36.3%(p<0.0001),操作者2为<37.1%(p<0.0001)。
- 预测无创通气失败的呼吸频率/DTF比值截断值:两操作者均为>0.6(p<0.0001)。
处置流程与药物剂量
- 由2名经过培训的操作者在基线、无创通气1、4、12、24、48、72和96小时和/或直至无创通气停止或插管时测量DTF和呼吸频率/DTF比值。
研究设计与关键结果
- 研究类型为初步生理学研究,纳入18例急诊科新发急性呼吸衰竭需无创通气治疗的患者,研究期为36个月。
- DTF评估总体重复性良好,组内相关系数(ICC)为0.82(95%CI 0.72-0.88)。
- 预测无创通气失败的DTF截断值:操作者1为<36.3%(p<0.0001),操作者2为<37.1%(p<0.0001)。
- 预测无创通气失败的呼吸频率/DTF比值截断值:两操作者均为>0.6(p<0.0001)。
证据类型、等级与局限
- 证据类型:初步生理学研究。
- 局限:原文未报告局限性。
对床旁实践的改变
- 作者认为,DTF和呼吸频率/DTF比值可能均是预测新发急性呼吸衰竭患者无创通气结局的有效、可行且无创的工具。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
BACKGROUND: A correlation between unsuccessful noninvasive ventilation (NIV) and poor outcome has been suggested in de-novo Acute Respiratory Failure (ARF) patients. Consequently, it is of paramount importance to identify accurate predictors of NIV outcome. The aim of our preliminary study is to evaluate the Diaphragmatic Thickening Fraction (DTF) and the respiratory rate/DTF ratio as predictors of NIV outcome in de-novo ARF patients.
METHODS: Over 36 months, we studied patients admitted to the emergency department with a diagnosis of de-novo ARF and requiring NIV treatment. DTF and respiratory rate/DTF ratio were measured by 2 trained operators at baseline, at 1, 4, 12, 24, 48, 72 and 96 h of NIV treatment and/or until NIV discontinuation or intubation. Receiver operating characteristic (ROC) curve analysis was performed to evaluate the ability of DTF and respiratory rate/DTF ratio to distinguish between patients who were successfully weaned and those who failed.
RESULTS: Eighteen patients were included. We found overall good repeatability of DTF assessment, with Intra-class Correlation Coefficient (ICC) of 0.82 (95% confidence interval 0.72-0.88). The cut-off values of DTF for prediction of NIV failure were < 36.3% and < 37.1% for the operator 1 and 2 (p < 0.0001), respectively. The cut-off value of respiratory rate/DTF ratio for prediction of NIV failure was > 0.6 for both operators (p < 0.0001).
CONCLUSION: DTF and respiratory rate/DTF ratio may both represent valid, feasible and noninvasive tools to predict NIV outcome in patients with de-novo ARF. Trial registration ClinicalTrials.gov Identifier: NCT02976233, registered 26 November 2016.
参考来源
- Mercurio G, D'Arrigo S, Moroni R, et al. Diaphragm thickening fraction predicts noninvasive ventilation outcome: a preliminary physiological study. Crit Care. 2021. PMID: 34174903. doi:10.1186/s13054-021-03638-x
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。