快速浅呼吸指数预测成功拔管的价值:系统评价与Meta分析
该系统评价与Meta分析检索六个数据库至2019年9月,纳入48项研究、10,946例患者的RSBI测量,评估RSBI预测成功拔管的准确性。RSBI<105预测拔管成功的汇总敏感度为0.83(95%CI 0.78-0.87,中等确定性),特异度差为0.58(95%CI 0.49-0.66,中等确定性),诊断OR为5.91(95%CI 4.09-8.52);RSBI<80与80-105阈值的敏感度、特异度和诊断OR相似,多个亚组分析结果一致。作者认为RSBI作为独立试验预测拔管成功敏感度中等、特异度差,未来研究应评估其作为允许性标准用于中等验前概率通过自主呼吸试验的患者。
要点
- RSBI<105预测拔管成功汇总敏感度0.83(95%CI 0.78-0.87,中等确定性),特异度仅0.58(95%CI 0.49-0.66,中等确定性)。
- RSBI<105的诊断OR为5.91(95%CI 4.09-8.52)。
- RSBI<80与80-105两个阈值的敏感度、特异度和诊断OR相似。
- 结果在反映不同患者特征和RSBI测量操作差异的多个亚组分析中一致。
- 作者认为RSBI作为独立试验敏感度中等、特异度差,未来应评估其作为允许性标准用于中等验前概率通过SBT的患者。
适用人群与场景
- 接受机械通气、评估拔管可能性的患者(48项研究中10,946例患者的RSBI测量)。
诊断标准与关键阈值
- RSBI<105预测拔管成功:汇总敏感度0.83(95%CI 0.78-0.87,中等确定性),特异度0.58(95%CI 0.49-0.66,中等确定性),诊断OR 5.91(95%CI 4.09-8.52)。
- RSBI<80与RSBI 80-105两个阈值的敏感度、特异度和诊断OR相似。
研究设计与关键结果
- 系统评价与Meta分析,检索六个数据库(自建库至2019年9月),纳入48项报告RSBI预测成功拔管准确性的研究,共10,946例患者的RSBI测量。
- RSBI<105预测拔管成功的汇总敏感度0.83(95%CI 0.78-0.87,中等确定性),特异度0.58(95%CI 0.49-0.66,中等确定性),诊断OR 5.91(95%CI 4.09-8.52)。
- RSBI<80或80-105阈值产生的敏感度、特异度和诊断OR相似。
- 上述结果在反映不同患者特征和RSBI测量操作差异的多个亚组分析中一致。
证据类型、等级与局限
- 证据类型:系统评价与Meta分析(PROSPERO注册号CRD42020149196)。
- 证据确定性:敏感度和特异度均为中等确定性。
- 局限:原文未报告局限性。
对床旁实践的改变
- 作者认为RSBI作为独立试验预测拔管成功敏感度中等、特异度差,未来研究应评估其作为允许性标准用于中等验前概率通过自主呼吸试验(SBT)的患者。
指南或共识出处
- PROSPERO;No. CRD42020149196;网址:www.crd.york.ac.uk/prospero/。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「处置流程与药物剂量」「红旗征与不能漏的情况」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
BACKGROUND: Clinicians use several measures to ascertain whether individual patients will tolerate liberation from mechanical ventilation, including the rapid shallow breathing index (RSBI).
RESEARCH QUESTION: Given varied use of different thresholds, patient populations, and measurement characteristics, how well does RSBI predict successful extubation?
STUDY DESIGN AND METHODS: We searched six databases from inception through September 2019 and selected studies reporting the accuracy of RSBI in the prediction of successful extubation. We extracted study data and assessed quality independently and in duplicate.
RESULTS: We included 48 studies involving RSBI measurements of 10,946 patients. Pooled sensitivity for RSBI of < 105 in predicting extubation success was moderate (0.83 [95% CI, 0.78-0.87], moderate certainty), whereas specificity was poor (0.58 [95% CI, 0.49-0.66], moderate certainty) with diagnostic ORs (DORs) of 5.91 (95% CI, 4.09-8.52). RSBI thresholds of < 80 or 80 to 105 yielded similar sensitivity, specificity, and DOR. These findings were consistent across multiple subgroup analyses reflecting different patient characteristics and operational differences in RSBI measurement.
INTERPRETATION: As a stand-alone test, the RSBI has moderate sensitivity and poor specificity for predicting extubation success. Future research should evaluate its role as a permissive criterion to undergo a spontaneous breathing trial (SBT) for patients who are at intermediate pretest probability of passing an SBT.
TRIAL REGISTRY: PROSPERO; No.: CRD42020149196; URL: www.crd.york.ac.uk/prospero/.
参考来源
- Trivedi V, Chaudhuri D, Jinah R, et al. The Usefulness of the Rapid Shallow Breathing Index in Predicting Successful Extubation: A Systematic Review and Meta-analysis. Chest. 2021. PMID: 34181953. doi:10.1016/j.chest.2021.06.030
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。