一句话结论护士穿戴生物安全二级防护服模拟儿童COVID-19复苏时,NIO-P与EZ-IO骨髓腔通路首次尝试成功率均100%,显著高于Jamshidi针和静脉通路,且建立时间更短。

该前瞻性、随机、交叉、单盲模拟试验纳入65名参加美国心脏协会认证高级心血管生命支持课程的护理人员,在穿戴生物安全二级防护服条件下比较NIO-P、EZ-IO、Jamshidi针三种骨髓腔装置与静脉通路在模拟儿童COVID-19复苏中的效果。结果显示NIO-P和EZ-IO首次尝试成功率均为100%,显著高于Jamshidi针(80.0%,p=0.02)和静脉通路(69.2%,p=0.005)。连接输液管时间NIO-P为33±4秒,短于EZ-IO的37±6.7秒(p<0.001)、Jamshidi的43±7秒(p<0.001)和静脉通路的98.5±10秒(p<0.001)。操作简易度评分NIO-P与EZ-IO均为2±1分(p=1.0),优于Jamshidi的5±3分(p<0.001)和静脉通路的7±2分(p<0.001)。作者认为NIO-P是最有效的血管通路方法,但需进一步临床试验证实。

要点

  • 穿戴生物安全二级防护服模拟儿童COVID-19复苏时,NIO-P和EZ-IO首次尝试成功率均为100%,显著高于Jamshidi针80.0%(p=0.02)和静脉通路69.2%(p=0.005)。
  • 连接输液管时间NIO-P为33±4秒,短于EZ-IO的37±6.7秒(p<0.001)、Jamshidi的43±7秒(p<0.001)和静脉通路的98.5±10秒(p<0.001)。
  • 操作简易度视觉模拟评分(1分容易,10分困难)NIO-P与EZ-IO均为2±1分(p=1.0),优于Jamshidi的5±3分(p<0.001)和静脉通路的7±2分(p<0.001)。
  • 作者认为NIO-P骨髓腔装置是穿戴生物安全二级防护服护士最有效的血管通路方法,但需进一步临床试验证实。

适用人群与场景

  • 参加美国心脏协会认证高级心血管生命支持课程的护理人员,共65名,随机分入不同研究组。
  • 模拟儿童COVID-19复苏场景,参与者穿戴生物安全二级防护服进行血管通路操作。

处置流程与药物剂量

  • 参与者接受使用不同装置进行血管通路的标准培训后,在穿戴生物安全二级防护服的条件下,依次以NIO-P、EZ-IO、Jamshidi针三种骨髓腔装置及静脉通路四种方法各进行一次血管通路操作;参与者和操作方法的顺序均随机。

研究设计与关键结果

  • 研究类型为前瞻性、随机、交叉、单盲模拟试验,共纳入65名护理人员,每名参与者均使用四种方法各完成一次血管通路操作。
  • 首次尝试成功率:NIO-P为100%,EZ-IO为100%,均显著高于Jamshidi针的80.0%(p=0.02)和静脉通路的69.2%(p=0.005)。
  • 从取出血管装置至连接输液管的时间:NIO-P为33±4秒,EZ-IO为37±6.7秒(与NIO-P比p<0.001),Jamshidi为43±7秒(p<0.001),静脉通路为98.5±10秒(p<0.001)。
  • 操作简易度视觉模拟评分(1分容易,10分困难):NIO-P为2±1分,EZ-IO为2±1分(两者比p=1.0),Jamshidi为5±3分(p<0.001),静脉通路为7±2分(p<0.001)。

证据类型、等级与局限

  • 证据类型:前瞻性、随机、交叉、单盲模拟试验。
  • 局限:作者指出需进一步临床试验证实结果。

对床旁实践的改变

  • 在模拟儿童COVID-19复苏中,穿戴生物安全二级防护服的护士采用骨髓腔通路(NIO-P、EZ-IO)较静脉通路能更快、更有效地建立血管通路。
  • 作者认为NIO-P骨髓腔装置是最有效的血管通路方法,但需进一步临床试验证实。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

BACKGROUND: Prehospital emergency care of children is challenging. In the era of the COVID-19 pandemic, when medical personnel should use personal protective equipment against aerosol-generating procedures, the efficiency of medical procedures may decrease. The study objective was to evaluate the effectiveness of different intravascular access methods applied by nurses wearing biosafety Level-2 suits in simulated paediatric COVID-19 resuscitation.

METHODS: A prospective, randomized, crossover, single-blinded simulation trial was performed. Nursing staff attending Advanced Cardiovascular Life Support courses accredited by the American Heart Association participated in the study. A total of 65 nurses were recruited and randomly assigned to different study groups. They received standard training on intravascular access methods employing distinct devices. The participants wore biosafety Level-2 suits and performed vascular access with the following intraosseous devices: NIO-P, EZ-IO, and Jamshidi needle; intravenous (IV) access was used as a reference method. Both the order of participants and the access methods were random. Each participant performed intravascular access with each of the four methods tested. The effectiveness of the first attempt to obtain intravascular access and the following time parameters were analysed: the time between grasping the intravascular device out of the original packing until infusion line connection. The ease of the procedure was measured with a visual analogue scale (1 - easy; 10 - difficult).

RESULTS: The first attempt success rate of intravascular access by using NIO-P and EZ-IO equalled 100% and was statistically significantly higher than that with the Jamshidi needle (80.0%; p = 0.02) and with the IV method (69.2%; p = 0.005). The time required to connect the infusion line varied and amounted to 33 ± 4 s for NIO-P compared to 37 ± 6.7 s for EZ-IO (p<0.001), 43 ± 7 s for Jamshidi (p<0.001), and 98.5 ± 10 s for IV access (p<0.001). The procedure was easiest in the case of NIO-P and EZ-IO (2 ± 1 points; p=1.0) compared with Jamshidi (5 ± 3 points; p<0.001) and IV access (7 ± 2 points; p<0.001).

CONCLUSION: The study provides evidence that nurses wearing biosafety Level-2 suits were able to obtain intraosseous access faster and more effectively as compared with IV access during simulated COVID-19 paediatric resuscitation. The most effective method of intravascular access was the NIO-P intraosseous device. Further clinical trials are necessary to confirm the results.