文献速递呼吸衰竭与机械通气复苏、休克与脓毒症重症综合管理与镇静镇痛

根据基础病理确定目标动脉血氧分压:机械通气患者现有数据的微型综述

Target arterial PO2 according to the underlying pathology: a mini-review of the available data in mechanically ventilated patients.
PubMed 文献 · Ann Intensive Care · 2021-06-02
一句话结论机械通气患者避免PaO2长时间(>24 h)低于55-60 mmHg或高于100 mmHg,高氧血症的利弊取决于是否存在循环性休克及组织缺氧病因。

本文综述机械通气患者高氧血症(PaO2高于生理水平)与预后的现有数据。多项回顾性研究发现ICU患者PaO2与死亡率/发病率呈U形关系,ICU入住最初24小时内PaO2约150 mmHg时死亡率最低。近期大规模回顾性分析多针对普通ICU人群,但不同基础病理及内科/外科患者间存在重大差异。作者按是否需要机械通气及有无循环性休克分层,认为除避免长时间(>24 h)暴露于低氧血症(PaO2 < 55-60 mmHg)或超生理水平(PaO2 > 100 mmHg)外,似乎没有理想的目标PaO2,高氧血症是否有害可能取决于机械通气需求、循环性休克有无及组织缺氧病因。

要点

  • 避免长时间(>24 h)暴露于低氧血症(PaO2 < 55-60 mmHg)或超生理水平(PaO2 > 100 mmHg)。
  • 多项回顾性研究显示ICU患者PaO2与死亡率/发病率呈U形关系,ICU入住最初24小时PaO2约150 mmHg时死亡率最低。
  • 近期大规模回顾性分析多针对普通ICU人群,但不同基础病理及内科/外科患者间存在重大差异。
  • 高氧血症是否有害可能取决于机械通气需求、循环性休克有无及组织缺氧病因(宏/微循环氧输送障碍和/或细胞氧利用障碍)。
  • 高氧血症的临床应用受限,因活性氧(ROS)生成增加可致氧毒性,尤其在缺血/再灌注条件下。

适用人群与场景

  • 机械通气患者,按是否需要机械通气及有无循环性休克分层。
  • 近期大规模回顾性分析多针对普通ICU人群,但不同基础病理及内科/外科患者间存在重大差异。

研究设计与关键结果

  • 多项研究报道ICU患者PaO2与死亡率/发病率呈U形关系。
  • 这些多为回顾性研究,发现ICU入住最初24小时内PaO2约150 mmHg时死亡率最低,即超生理PaO2水平。
  • 近期大规模回顾性分析多针对普通ICU人群,但不同基础病理及内科/外科患者间存在重大差异。
  • 除避免长时间(>24 h)暴露于低氧血症(PaO2 < 55-60 mmHg)或超生理水平(PaO2 > 100 mmHg)外,似乎没有理想的目标PaO2。

证据类型、等级与局限

  • 证据类型:微型综述,汇总现有数据。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为,高氧血症是否有害可能取决于机械通气需求、循环性休克有无及组织缺氧病因(宏/微循环氧输送障碍和/或细胞氧利用障碍)。
  • 作者认为,除避免长时间(>24 h)暴露于低氧血症(PaO2 < 55-60 mmHg)或超生理水平(PaO2 > 100 mmHg)外,似乎没有理想的目标PaO2。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

There is an ongoing discussion whether hyperoxia, i.e. ventilation with high inspiratory O2 concentrations (FIO2), and the consecutive hyperoxaemia, i.e. supraphysiological arterial O2 tensions (PaO2), have a place during the acute management of circulatory shock. This concept is based on experimental evidence that hyperoxaemia may contribute to the compensation of the imbalance between O2 supply and requirements. However, despite still being common practice, its use is limited due to possible oxygen toxicity resulting from the increased formation of reactive oxygen species (ROS) limits, especially under conditions of ischaemia/reperfusion. Several studies have reported that there is a U-shaped relation between PaO2 and mortality/morbidity in ICU patients. Interestingly, these mostly retrospective studies found that the lowest mortality coincided with PaO2 ~ 150 mmHg during the first 24 h of ICU stay, i.e. supraphysiological PaO2 levels. Most of the recent large-scale retrospective analyses studied general ICU populations, but there are major differences according to the underlying pathology studied as well as whether medical or surgical patients are concerned. Therefore, as far as possible from the data reported, we focus on the need of mechanical ventilation as well as the distinction between the absence or presence of circulatory shock. There seems to be no ideal target PaO2 except for avoiding prolonged exposure (> 24 h) to either hypoxaemia (PaO2 < 55-60 mmHg) or supraphysiological (PaO2 > 100 mmHg). Moreover, the need for mechanical ventilation, absence or presence of circulatory shock and/or the aetiology of tissue dysoxia, i.e. whether it is mainly due to impaired macro- and/or microcirculatory O2 transport and/or disturbed cellular O2 utilization, may determine whether any degree of hyperoxaemia causes deleterious side effects.

来源:Ann Intensive Care,查看原文。版权归原作者所有。

参考来源

  1. Demiselle J, Calzia E, Hartmann C, et al. Target arterial PO2 according to the underlying pathology: a mini-review of the available data in mechanically ventilated patients. Ann Intensive Care. 2021. PMID: 34076802. doi:10.1186/s13613-021-00872-y

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。