文献速递心脑血管急症重症综合管理与镇静镇痛

心脏死亡的电脑特征

Electrocerebral Signature of Cardiac Death.
PubMed 文献 · Neurocrit Care · 2021-06-28
一句话结论心脏骤停死亡过程中,脑电静息多出现在估计脑血流停止后,极少数患者在心电图最后QRS波后仍有短暂电脑活动(不足5分钟)。

该回顾性研究分析了19例在ICU接受标准脑电监测期间死于心脏骤停的患者(排除脑死亡先于心脏死亡者),以最后记录到的QRS波(QRS0)、估计脑血流停止(CBF0,血压和心率降至设定阈值以下)和脑电静息(EEG0)三个时间点评估脑电频谱功率、相干性和排列熵。EEG0在5例与QRS0同时出现、2例在QRS0之后出现(队列中位数-2.0,四分位距-8.0至0.0);EEG0在6例与CBF0同时出现、11例在CBF0之后出现(队列中位数2.0分钟,四分位距-1.5至6.0)。CBF0后全频谱对数功率(p<0.001)和相干性(p<0.001)下降,而delta(p=0.007)和theta(p<0.001)排列熵升高。作者认为这些结果可能对心肺复苏和器官捐献的讨论有启示。

要点

  • 19例心脏骤停死亡患者中,EEG0在5例与QRS0同时、2例在QRS0之后出现(队列中位数-2.0,四分位距-8.0至0.0)。
  • EEG0在6例与CBF0同时、11例在CBF0之后出现(队列中位数2.0分钟,四分位距-1.5至6.0)。
  • CBF0后全频谱对数功率(p<0.001)和相干性(p<0.001)下降,delta(p=0.007)和theta(p<0.001)排列熵升高。
  • 19例中7例(37%)为仅舒适照护状态,18例(95%)死亡时已签署不复苏医嘱。
  • 作者认为,少数患者在心电图最后QRS波后(不足5分钟)和估计脑血流停止后仍可能有短暂电脑活动,可能对心肺复苏和器官捐献讨论有启示。

适用人群与场景

  • 在ICU接受标准脑电监测期间死于心脏骤停的患者;排除脑死亡先于心脏死亡者。
  • 19例中7例(37%)死亡时为仅舒适照护状态,18例(95%)死亡时已签署不复苏医嘱。

诊断标准与关键阈值

  • 以最后记录到的QRS波(QRS0)、估计脑血流停止(CBF0,血压和心率降至设定阈值以下)和脑电静息(EEG0)为三个事件时间点。

研究设计与关键结果

  • 回顾性分析19例在ICU接受标准脑电监测期间死于心脏骤停的患者(排除脑死亡先于心脏死亡者),评估QRS0、CBF0和EEG0时间点的脑电频谱功率、相干性和排列熵。
  • EEG0在5例与QRS0同时出现、2例在QRS0之后出现(队列中位数-2.0,四分位距-8.0至0.0);EEG0在6例与CBF0同时出现、11例在CBF0之后出现(队列中位数2.0分钟,四分位距-1.5至6.0)。
  • CBF0后全频谱对数功率(p<0.001)和相干性(p<0.001)下降,delta(p=0.007)和theta(p<0.001)排列熵升高。

证据类型、等级与局限

  • 回顾性研究;作者认为少数患者在心电图最后QRS波后(不足5分钟)和估计脑血流停止后仍可能有短暂电脑活动,这些结果可能对心肺复苏和器官捐献的讨论有启示。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为,这些结果可能对心肺复苏和器官捐献的讨论有启示。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

BACKGROUND: Electroencephalography (EEG) findings following cardiovascular collapse in death are uncertain. We aimed to characterize EEG changes immediately preceding and following cardiac death.

METHODS: We retrospectively analyzed EEGs of patients who died from cardiac arrest while undergoing standard EEG monitoring in an intensive care unit. Patients with brain death preceding cardiac death were excluded. Three events during fatal cardiovascular failure were investigated: (1) last recorded QRS complex on electrocardiogram (QRS0), (2) cessation of cerebral blood flow (CBF0) estimated as the time that blood pressure and heart rate dropped below set thresholds, and (3) electrocerebral silence on EEG (EEG0). We evaluated EEG spectral power, coherence, and permutation entropy at these time points.

RESULTS: Among 19 patients who died while undergoing EEG monitoring, seven (37%) had a comfort-measures-only status and 18 (95%) had a do-not-resuscitate status in place at the time of death. EEG0 occurred at the time of QRS0 in five patients and after QRS0 in two patients (cohort median - 2.0, interquartile range - 8.0 to 0.0), whereas EEG0 was seen at the time of CBF0 in six patients and following CBF0 in 11 patients (cohort median 2.0 min, interquartile range - 1.5 to 6.0). After CBF0, full-spectrum log power (p < 0.001) and coherence (p < 0.001) decreased on EEG, whereas delta (p = 0.007) and theta (p < 0.001) permutation entropy increased.

CONCLUSIONS: Rarely may patients have transient electrocerebral activity following the last recorded QRS (less than 5 min) and estimated cessation of cerebral blood flow. These results may have implications for discussions around cardiopulmonary resuscitation and organ donation.

来源:Neurocrit Care,查看原文。版权归原作者所有。

参考来源

  1. Matory AL, Alkhachroum A, Chiu WT, et al. Electrocerebral Signature of Cardiac Death. Neurocrit Care. 2021. PMID: 34184175. doi:10.1007/s12028-021-01233-0

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。