床旁超声判断儿童前臂骨折复位充分性的准确性
本研究在儿童急诊环境下评估床旁超声(POCUS)判断儿童前臂骨折闭合复位(CR)充分性的准确性。由骨科顾问依据X线确定需要CR后,在复位尝试前后行POCUS,探头纵向置于桡骨与尺骨的背侧、掌侧和外侧观察骨折部位,记录成角、移位或骨折端嵌插。共纳入62例患者、评估96块骨。POCUS判断CR充分性的敏感度95.8%(95%CI 88.3-99.1)、特异度95.8%(95%CI 78.8-99.8),阳性预测值98.5%(95%CI 91.0-99.7)、阴性预测值88.4%(95%CI 71.6-95.8),阳性似然比23(3.37-156.77)、阴性似然比0.04(0.01-0.12);POCUS与X线判断CR充分性高度一致(κ=0.892,±0.053),两者复位前后测量的成角和移位显著相关(p<0.001)。作者认为POCUS可用于儿童急诊前臂骨折管理,能减少辐射暴露,似乎是复位尝试的替代且准确的工具。
要点
- 在儿童急诊,骨科顾问依据X线确定需闭合复位后,床旁超声判断复位充分性的敏感度95.8%、特异度95.8%。
- 床旁超声阳性预测值98.5%、阴性预测值88.4%,阳性似然比23、阴性似然比0.04。
- 床旁超声与X线判断闭合复位充分性高度一致,κ=0.892(±0.053)。
- 床旁超声与X线在复位前后测量的成角和移位显著相关(p<0.001)。
- 作者认为床旁超声可减少辐射暴露,似乎是儿童前臂骨折复位尝试的替代且准确的工具。
适用人群与场景
- 儿童急诊环境中因前臂骨折需行闭合复位的儿童患者,共纳入62例患者、评估96块骨。
- 由骨科顾问依据X线图像确定需要闭合复位者。
诊断标准与关键阈值
- 床旁超声探头纵向置于桡骨和尺骨的背侧、掌侧及外侧表面观察骨折部位,记录骨折端成角、移位或嵌插。
- 以骨科顾问的最终判断作为复位充分性的参照。
处置流程与药物剂量
- 骨科顾问依据X线确定需要闭合复位后,在复位尝试前和复位尝试后分别行床旁超声检查。
- 床旁超声探头纵向置于桡骨和尺骨的背侧、掌侧和外侧表面,观察骨折部位,记录成角、移位或骨折端嵌插。
- 分别记录依据床旁超声判断的复位充分性和骨科顾问的最终判断。
研究设计与关键结果
- 研究类型为在儿童急诊环境下评估床旁超声判断儿童前臂骨折闭合复位充分性准确性的研究,纳入62例患者、评估96块骨。
- 床旁超声判断闭合复位充分性的敏感度95.8%(95%CI 88.3-99.1)、特异度95.8%(95%CI 78.8-99.8)。
- 阳性预测值98.5%(95%CI 91.0-99.7),阴性预测值88.4%(95%CI 71.6-95.8)。
- 阳性似然比23(3.37-156.77),阴性似然比0.04(0.01-0.12)。
- 床旁超声与X线判断闭合复位充分性高度一致,κ=0.892(±0.053)。
- 床旁超声与X线在复位前后测量的成角和移位显著相关(p<0.001)。
证据类型、等级与局限
- 证据类型:在儿童急诊环境下评估床旁超声准确性的临床研究。
- 局限:原文未报告局限性。
对床旁实践的改变
- 作者认为,床旁超声可用于儿童急诊前臂骨折的管理,能减少辐射暴露,似乎是复位尝试的替代且准确的工具。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
BACKGROUND: The objective of the present study was to the determine the accuracy of point-of-care ultrasound (POCUS) in assessing closed reduction (CR) of pediatric forearm fractures in a pediatric emergency setting.
METHODS: After determination of the need for CR using X-ray images by an orthopedic consultant, POCUS examinations were performed just before and after the reduction attempt. The transducer was positioned longitudinally over the dorsal, volar, and lateral surfaces of the radius and ulna to view the fracture site. The presence of angulation, displacement, or bayonetting of the fracture fragments was recorded. The adequacy of realignment according to the POCUS and the orthopedic consultant's final determination were recorded.
RESULTS: Sixty-two patients were enrolled in the study and 96 bones were evaluated. The sensitivity and specificity of POCUS for adequacy of CR were 95.8% [95% confidence interval (CI): 88.3-99.1)] and 95.8% (95% CI: 78.8-99.8), the positive predictive value was 98.5% (95% CI: 91.0-99.7), and the negative predictive value was 88.4% (95% CI: 71.6-95.8). The corresponding positive and negative likelihood ratios were 23 (3.37-156.77) and 0.04 (0.01-0.12). There was high agreement between POCUS and X-ray images for predicting adequacy of CR [κ: 0.892 (±0.053)]. There was also a significant correlation between POCUS and X-ray measurements of angulation and displacement performed before and after CR, respectively (p < 0.001).
CONCLUSION: Our study has reported the successful use of POCUS for the management of pediatric forearm fractures in a pediatric emergency department. Point-of-care ultrasound can minimize radiation exposure and appears to be an alternative and accurate tool for reduction attempts.
参考来源
- Şık N, Öztürk A, Koşay MC, et al. Accuracy of point-of-care ultrasound for determining the adequacy of pediatric forearm fracture reductions. Am J Emerg Med. 2021. PMID: 33992985. doi:10.1016/j.ajem.2021.05.021
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。