文献速递儿科与产科急症心脑血管急症

儿童视盘抬高床旁超声检测颅内压升高:一项先导研究

Pediatric point-of-care ultrasound of optic disc elevation for increased intracranial pressure: A pilot study.
PubMed 文献 · Am J Emerg Med · 2021-05-21
一句话结论儿童眼部床旁超声测量双眼视盘抬高均值(ODE-B),以0.66 mm为界值检测颅内压升高,敏感度96%、特异度93%。

该研究回顾性分析了2011至2016年在一家三级儿童急诊科接受眼部床旁超声(POCUS)的0至18岁患者的病历,纳入超声图像质量高且在POCUS后48小时内明确颅内压(ICP)状态者,由盲法POCUS专家测量视盘抬高(ODE)、视盘中高宽度(ODWAMH)和视神经鞘直径(ONSD)。共纳入40例患者76只眼,其中26例颅内压升高。双眼ODE均值(ODE-B)的曲线下面积最大(0.962,95%CI 0.890-1),最佳界值0.66 mm,敏感度96%(95%CI 79-100%)、特异度93%(95%CI 79-100%)。作者认为ODE-B可能是检测儿童颅内压升高的最佳眼部POCUS指标,未来前瞻性研究可更准确描述不同儿童ODE-B界值的诊断性能。

要点

  • 在40例患儿76只眼中,双眼ODE均值(ODE-B)检测颅内压升高的曲线下面积为0.962(95%CI 0.890-1)。
  • ODE-B最佳界值为0.66 mm,敏感度96%(95%CI 79-100%),特异度93%(95%CI 79-100%)。
  • ODE-B < 0.66 mm的患者中仅1/40(2.5%)存在颅内压升高。
  • 该研究为回顾性先导研究,作者指出未来前瞻性研究可更准确描述不同儿童ODE-B界值的诊断性能。

适用人群与场景

  • 0至18岁、在一家三级儿童急诊科接受眼部床旁超声(POCUS)的患者。
  • 纳入条件:存档POCUS图像经POCUS专家判定为高质量,且在眼部POCUS后48小时内进行了颅内压(ICP)测定。

诊断标准与关键阈值

  • 双眼视盘抬高均值(ODE-B)最佳界值0.66 mm,用于检测儿童颅内压升高。
  • ODE-B < 0.66 mm的患者中1/40(2.5%)存在颅内压升高。

研究设计与关键结果

  • 研究类型:回顾性病历审查(先导研究),纳入2011至2016年一家三级儿童急诊科40例患者共76只眼,其中26例颅内压升高。
  • 由盲法POCUS专家测量ODE、视盘中高宽度(ODWAMH)和视神经鞘直径(ONSD),并进行受试者工作特征曲线分析。
  • 双眼ODE均值(ODE-B)的曲线下面积最大,为0.962(95%CI 0.890-1)。
  • ODE-B最佳界值0.66 mm,敏感度96%(95%CI 79-100%),特异度93%(95%CI 79-100%)。
  • ODE-B < 0.66 mm的患者中1/40(2.5%)存在颅内压升高。

证据类型、等级与局限

  • 证据类型:回顾性先导研究。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为ODE-B可能是检测儿童颅内压升高的最佳眼部POCUS测量指标。
  • 作者指出未来前瞻性研究可更准确描述不同儿童ODE-B界值的诊断性能。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

OBJECTIVE: Papilledema is often difficult to detect in children. Ocular point-of-care ultrasound (POCUS) measurement of the optic nerve sheath diameter (ONSD) is a non-invasive test for increased intracranial pressure (ICP), but no consensus exists on normal pediatric ONSD values. Detection of optic disc elevation (ODE, a component of papilledema) using POCUS has recently been qualitatively described. We sought to establish the diagnostic accuracy of different ODE cutoffs to detect increased ICP in children who underwent ocular POCUS in our pediatric emergency department (PED).

METHODS: We retrospectively reviewed charts of patients ages 0-18 years who received ocular POCUS in our tertiary PED between 2011 and 2016. Patients were included if their archived POCUS examinations were deemed high-quality by a POCUS expert and they underwent ICP determination within 48 h after ocular POCUS. A blinded POCUS expert measured ODE, optic disc width at mid-height (ODWAMH), and ONSD. Receiver-operator curve analysis was performed for various cutoffs for these measurements in detecting increased ICP.

RESULTS: 76 eyes from 40 patients met study criteria. 26 patients had increased ICP. The mean ODE of both eyes (ODE-B) generated the largest area under the curve (0.962, 95% CI 0.890-1). The optimal ODE-B cutoff was 0.66 mm, with a sensitivity of 96% (95% CI 79-100%) and a specificity of 93% (95% CI 79-100%). 1/40 (2.5%) of patients with ODE-B < 0.66 had increased ICP.

CONCLUSIONS: ODE-B may represent the optimal ocular POCUS measurement for detecting increased ICP in children, and future prospective studies could more accurately describe the diagnostic performance of different pediatric ODE-B cutoffs.

来源:Am J Emerg Med,查看原文。版权归原作者所有。

参考来源

  1. Tessaro MO, Friedman N, Al-Sani F, et al. Pediatric point-of-care ultrasound of optic disc elevation for increased intracranial pressure: A pilot study. Am J Emerg Med. 2021. PMID: 34051397. doi:10.1016/j.ajem.2021.05.051

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。