低潮气量机械通气危重患者容量反应性预测因素的系统评价与Meta分析
该系统评价与Meta分析纳入33项研究共1352例成人患者,评估潮气量≤8 ml/kg机械通气、无自主呼吸努力及心律失常条件下,PPV、SVV、EEOT、PLR、Δ-IVC、m-FC和VtC对容量反应性的预测效能。各预测因素AUC分别为PPV 0.82、Δ-IVC 0.86、SVV 0.90、m-FC 0.84、PLR 0.84、EEOT 0.92、VtC 0.92。亚组分析显示,心输出量测量方法、呼吸系统顺应性、患者类型、容量反应性判定阈值及输注液量等因素可显著影响部分预测因素的效能。敏感性分析未发现PPV、SVV和EEOT的预测效能存在显著变化。
要点
- 在潮气量≤8 ml/kg机械通气的成人患者中,EEOT和VtC的AUC均为0.92,预测容量反应性效能最高。
- PPV的AUC为0.82,其预测效能受心输出量测量方法和呼吸系统顺应性显著影响(p<0.05和p=0.05)。
- SVV的AUC为0.90,其预测效能受心输出量测量方法、患者类型、判定阈值和输注液量显著影响(p<0.05、p<0.01、p=0.05和p=0.01)。
- PLR的AUC为0.84,其预测效能受用于判定心输出量变化的输注液量显著影响(p<0.01)。
- 敏感性分析显示PPV(p=0.39)、SVV(p=0.23)和EEOT(p=0.15)的预测效能无显著变化。
适用人群与场景
- 成人危重患者,机械通气潮气量≤8 ml/kg,无自主呼吸努力,无心律失常,研究发表于1999年至2020年。
研究设计与关键结果
- 系统评价与Meta分析,纳入33项研究,共1352例患者。
- 预测容量反应性的AUC:PPV=0.82,Δ-IVC=0.86,SVV=0.90,m-FC=0.84,PLR=0.84,EEOT=0.92,VtC=0.92。
- 亚组分析显示,心输出量测量方法及据此分类容量反应者有或无的方法显著影响PPV和SVV的预测效能(p<0.05)。
- PPV的预测效能还显著受呼吸系统顺应性影响(p=0.05)。
- SVV的预测效能显著受患者类型(p<0.01)和判定容量反应性的阈值(p=0.05)影响。
- 用于判定心输出量变化的输注液量显著影响SVV(p=0.01)和PLR(p<0.01)的预测效能。
- 基于QUADAS-2方法学质量的敏感性分析显示,PPV(p=0.39)、SVV(p=0.23)和EEOT(p=0.15)的预测效能无显著变化。
证据类型、等级与局限
- 证据类型:系统评价与Meta分析。
对床旁实践的改变
- 在潮气量≤8 ml/kg机械通气的成人患者中,多数容量反应性预测因素能可靠预测扩容后心输出量反应,但技术和临床变量可能明显影响其预测效能。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
INTRODUCTION: Dynamic predictors of fluid responsiveness have shown good performance in mechanically ventilated patients at tidal volumes (Vt) > 8 mL kg-1. Nevertheless, most critically ill conditions demand lower Vt. We sought to evaluate the operative performance of several predictors of fluid responsiveness at Vt ≤ 8 mL kg-1 by using meta-regression and subgroup analyses.
METHODS: A sensitive search was conducted in the Embase and MEDLINE databases. We searched for studies prospectively assessing the operative performance of pulse pressure variation (PPV), stroke volume variation (SVV), end-expiratory occlusion test (EEOT), passive leg raising (PLR), inferior vena cava respiratory variability (Δ-IVC), mini-fluid challenge (m-FC), and tidal volume challenge (VtC), to predict fluid responsiveness in adult patients mechanically ventilated at Vt ≤ 8 ml kg-1, without respiratory effort and arrhythmias, published between 1999 and 2020. Operative performance was assessed using hierarchical and bivariate analyses, while subgroup analysis was used to evaluate variations in their operative performance and sources of heterogeneity. A sensitivity analysis based on the methodological quality of the studies included (QUADAS-2) was also performed.
RESULTS: A total of 33 studies involving 1,352 patients were included for analysis. Areas under the curve (AUC) values for predictors of fluid responsiveness were: for PPV = 0.82, Δ-IVC = 0.86, SVV = 0.90, m-FC = 0.84, PLR = 0.84, EEOT = 0.92, and VtC = 0.92. According to subgroup analyses, variations in methods to measure cardiac output and in turn, to classify patients as responders or non-responders significantly influence the performance of PPV and SVV (p < 0.05). Operative performance of PPV was also significantly affected by the compliance of the respiratory system (p = 0.05), while type of patient (p < 0.01) and thresholds used to determine responsiveness significantly affected the predictability of SVV (p = 0.05). Similarly, volume of fluids infused to determine variation in cardiac output, significantly affected the performance of SVV (p = 0.01) and PLR (p < 0.01). Sensitivity analysis showed no variations in operative performance of PPV (p = 0.39), SVV (p = 0.23) and EEOT (p = 0.15).
CONCLUSION: Most predictors of fluid responsiveness reliably predict the response of cardiac output to volume expansion in adult patients mechanically ventilated at tidal volumes ≤ 8 ml kg-1. Nevertheless, technical and clinical variables might clearly influence on their operative performance.
参考来源
- Alvarado Sánchez JI, Caicedo Ruiz JD, Diaztagle Fernández JJ, et al. Predictors of fluid responsiveness in critically ill patients mechanically ventilated at low tidal volumes: systematic review and meta-analysis. Ann Intensive Care. 2021. PMID: 33555488. doi:10.1186/s13613-021-00817-5
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。