文献速递儿科与产科急症消化、代谢与肾脏急症

急诊医师床旁超声检测儿童肠套叠的评价

Evaluation of bedside sonography performed by emergency physicians to detect intussusception in children in the emergency department.
PubMed 文献 · Acad Emerg Med · 2021-03-14
一句话结论急诊医师经1小时培训后行床旁超声诊断儿童肠套叠,敏感度0.87、特异度0.97;排除不确定检查后敏感度升至0.98。

本研究为三级儿科急诊前瞻性队列研究的亚分析,纳入疑似肠套叠需腹部超声的5岁以下儿童131例,由24名不同超声经验的急诊医师在体检后、影像学评估前行床旁超声,以儿科放射科医师的超声判读为标准。肠套叠45例(34%),床旁超声敏感度0.87(95%CI 0.74–0.94),特异度0.97(95%CI 0.90–0.99);排除28例医师报告不确定的检查后,敏感度0.98(95%CI 0.97–1.00)、特异度0.94(95%CI 0.85–0.99)。经验丰富者诊断准确率42/43(98%),新手81/88(92%)。作者结论为床旁超声对儿童肠套叠具有很好的敏感度和特异度。

要点

  • 131例疑似肠套叠的5岁以下儿童中45例(34%)确诊,床旁超声敏感度0.87(95%CI 0.74–0.94)、特异度0.97(95%CI 0.90–0.99)。
  • 排除28例医师报告不确定的检查后,敏感度升至0.98(95%CI 0.97–1.00)、特异度0.94(95%CI 0.85–0.99)。
  • 经验丰富者床旁超声诊断准确率42/43(98%),新手81/88(92%)。
  • 医师接受1小时肠套叠超声讲授与实操培训,床旁超声在初次体检后、进一步影像学评估前完成。
  • 24名急诊医师共完成1至25例床旁超声检查,最终结局由儿科放射科医师影像评估确定。

适用人群与场景

  • 三级儿科急诊中因疑似肠套叠需行腹部超声的5岁以下儿童。
  • 由不同床旁超声经验的急诊医师在初次体检后、进一步影像学评估前实施检查。

研究设计与关键结果

  • 前瞻性队列研究亚分析,共131例儿童接受床旁超声,45例(34%)为肠套叠,24名医师每人完成1至25例检查。
  • 床旁超声识别45例肠套叠中的39例,敏感度0.87(95%CI 0.74–0.94);86例阴性检查中83例报告正常或不确定,特异度0.97(95%CI 0.90–0.99)。
  • 排除28例医师报告不确定的检查后,敏感度0.98(95%CI 0.97–1.00),特异度0.94(95%CI 0.85–0.99)。
  • 经验丰富者床旁超声诊断准确率42/43(98%),新手81/88(92%)。

证据类型、等级与局限

  • 证据类型:前瞻性队列研究的亚分析。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者结论认为,由不同床旁超声经验的多名急诊医师操作时,床旁超声对儿童肠套叠具有很好的敏感度和特异度。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

OBJECTIVE: The aim of our study was to evaluate the test characteristics of point-of-care ultrasound (POCUS) performed by emergency physicians with varying levels of experience among children having undergone diagnostic radiology ultrasound for intussusception in a pediatric emergency department (PED).

METHODS: This was a subanalysis of a prospective cohort study conducted at a tertiary care PED. The study population was a sample of children younger than 5 years old who required an abdominal ultrasound for suspected intussusception. Participating physicians had varying levels of POCUS experience. They received a 1-hour didactic and practical training session on intussusception ultrasound. All POCUS was performed following the initial physical examination and prior to further radiologic evaluation. The final outcome was determined by radiologic evaluation performed by a pediatric radiologist. Test characteristics were calculated for POCUS compared with the criterion standard of ultrasound read by a pediatric radiologist. A secondary analysis compared test characteristics of POCUS performed by physicians with different level of POCUS training.

RESULTS: A total of 131 children were evaluated by POCUS, of whom 45 (34%) had an intussusception. Twenty-four physicians performed between one and 25 POCUS procedures. POCUS identified 39 of 45 intussusception cases, with a sensitivity of 0.87 (95% confidence interval [CI] = 0.74 to 0.94). A normal or inconclusive POCUS was reported for 83 of the 86 negative studies, with a specificity of 0.97 (95% CI = 0.90 to 0.99). When excluding the 28 patients for whom the physician reported an inconclusive examination, the sensitivity improved to 0.98 (95% CI = 0.97 to 1.00) and the specificity to 0.94 (95% CI = 0.85 to 0.99). The accuracy of diagnosis using POCUS was 42 of 43 (98%) for experienced sonographers in comparison to 81 of 88 (92%) for novices.

CONCLUSION: This study demonstrated a very good sensitivity and specificity of POCUS for intussusception in children when performed by multiple emergency physicians with varying POCUS experience.

来源:Acad Emerg Med,查看原文。版权归原作者所有。

参考来源

  1. Tonson la Tour A, Desjardins MP, Gravel J, et al. Evaluation of bedside sonography performed by emergency physicians to detect intussusception in children in the emergency department. Acad Emerg Med. 2021. PMID: 33548161. doi:10.1111/acem.14226

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。