文献速递复苏、休克与脓毒症创伤与烧伤

失血性休克条件下完全与部分复苏性血管内球囊阻断主动脉时脑灌注是否维持

Is cerebral perfusion maintained during full and partial resuscitative endovascular balloon occlusion of the aorta in hemorrhagic shock conditions?
PubMed 文献 · J Trauma Acute Care Surg · 2021-01-01
一句话结论猪失血性休克模型中,完全与部分充盈pREBOA时颈动脉血流增加或维持,且与近端平均动脉压及手持COMPASS装置相关性良好。

本研究为猪失血性损伤模型,共10头猪,经动脉置管监测颈动脉与髂动脉压,多普勒血流探头监测颈动脉与主动脉血流,放置COMPASS监测近端压力。pREBOA充盈15分钟后部分放气使主动脉血流率维持0.7 L/min共45分钟,随后完全放气。结果显示完全充盈时颈动脉血流率增加240%,部分放气期间颈动脉血流率维持于基线的100%至150%,完全放气后短暂降至基线的45%至95%。颈动脉血流率与近端平均动脉压及COMPASS测量值均呈正相关。作者认为部分pREBOA放气期间颈动脉灌注似可维持,且可用手持COMPASS装置监测。

要点

  • 猪失血性损伤模型中,pREBOA完全充盈时颈动脉血流率增加240%。
  • 部分放气使主动脉血流率维持0.7 L/min的45分钟内,颈动脉血流率维持于基线100%至150%。
  • 完全放气后颈动脉血流率短暂降至基线45%至95%。
  • 完全充盈后颈动脉血流率与近端平均动脉压强正相关(r>0.85),部分充盈时正相关(r>0.7)。
  • 颈动脉血流率与COMPASS装置在完全REBOA时强相关(r>0.85),在部分REBOA时正相关(r>0.65)。

适用人群与场景

  • 猪失血性损伤模型,共10头猪,建立颈动脉与髂动脉置管及多普勒血流探头监测。

处置流程与药物剂量

  • pREBOA充盈15分钟后部分放气,调整至主动脉血流率0.7 L/min并维持45分钟,随后完全放气。
  • 近端平均动脉压经动脉置管测量,近端压力另用COMPASS(Mirador Biomedical,西雅图,华盛顿州)手持装置监测。

研究设计与关键结果

  • 研究类型:猪失血性损伤模型实验,样本量10头猪。
  • 干预:pREBOA充盈15分钟,部分放气至主动脉血流率0.7 L/min维持45分钟,随后完全放气。
  • 主要结果:完全充盈时颈动脉血流率增加240%;部分放气期间颈动脉血流率维持于基线100%至150%;完全放气后颈动脉血流率短暂降至基线45%至95%。
  • 相关性:完全充盈后颈动脉血流率与近端平均动脉压强正相关(r>0.85),部分充盈时正相关(r>0.7);颈动脉血流率与COMPASS在完全REBOA时强相关(r>0.85),在部分REBOA时正相关(r>0.65)。

证据类型、等级与局限

  • 证据类型:动物实验(猪失血性损伤模型)。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为,部分pREBOA放气期间颈动脉灌注似可维持,且可用手持便携COMPASS装置而非标准动脉置管装置方便地监测。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

BACKGROUND: Partial resuscitative endovascular balloon occlusion of the aorta (pREBOA) is a technology that occludes aortic flow and allows for controlled deflation and restoration of varying distal perfusion. Carotid flow rates (CFRs) during partial deflation are unknown. Our aim was to measure CFR with the different pREBOA balloon volumes and correlate those to the proximal mean arterial pressure (PMAP) and a handheld pressure monitoring device (COMPASS; Mirador Biomedical, Seattle, WA).

METHODS: Ten swine underwent a hemorrhagic injury model with carotid and iliac arterial pressures monitored via arterial lines. Carotid and aortic flow rates were monitored with Doppler flow probes. A COMPASS was placed to monitor proximal pressure. The pREBOA was inflated for 15 minutes then partially deflated for an aortic flow rate of 0.7 L/min for 45 minutes. It was then completely deflated. Proximal mean arterial pressures and CFR were measured, and correlation was evaluated. Correlation between CRF and COMPASS measurements was evaluated.

RESULTS: Carotid flow rate increased 240% with full inflation. Carotid flow rate was maintained at 100% to 150% of baseline across a wide range of partial deflation. After full deflation, CFR transiently decreased to 45% to 95% of baseline. There was strong positive correlation (r > 0.85) between CFR and PMAP after full inflation, and positive correlation with partial inflation (r > 0.7). Carotid flow rate had strong correlation with the COMPASS with full REBOA (r > 0.85) and positive correlation with pREBOA (r > 0.65).

CONCLUSION: Carotid flow rate is increased in a hemorrhagic model during full and partial inflation of the pREBOA and correlates well with PMAP. Carotid perfusion appears maintained across a wide range of pREBOA deflation and could be readily monitored with a handheld portable COMPASS device instead of a standard arterial line setup.

来源:J Trauma Acute Care Surg,查看原文。版权归原作者所有。

参考来源

  1. Benham DA, Calvo RY, Carr MJ, et al. Is cerebral perfusion maintained during full and partial resuscitative endovascular balloon occlusion of the aorta in hemorrhagic shock conditions? J Trauma Acute Care Surg. 2021. PMID: 33605703. doi:10.1097/TA.0000000000003124

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。