文献速递呼吸衰竭与机械通气重症综合管理与镇静镇痛

不同潮气量机械通气对急性呼吸窘迫综合征大鼠右心室血流动力学的影响

[Effects of mechanical ventilation with different tidal volumes on right ventricular hemodynamics in acute respiratory distress syndrome rats].
PubMed 文献 · Zhonghua Wei Zhong Bing Ji Jiu Yi Xue · 2021-01-01
一句话结论油酸诱导的ARDS大鼠中,6 mL/kg小潮气量通气4小时较轻者改善血气与右心血流动力学,20 mL/kg大潮气量则恶化右心功能。

研究将60只成年雄性SD大鼠分为对照组、ARDS模型组、低潮气量组与高潮气量组,经颈静脉注射油酸0.15 mL/kg复制ARDS模型。建模2小时后低潮气量组与高潮气量组分别以6 mL/kg或20 mL/kg潮气量机械通气4小时,对照组与模型组保持自主呼吸。低潮气量组血气指标及心率、血压、右心室压力上升最大速率均优于模型组与高潮气量组,右心室收缩压低于后两组。结论认为小潮气量机械通气可改善ARDS大鼠右心室血流动力学并保护右心功能。

要点

  • 低潮气量组血气优于模型组与高潮气量组:pH 7.36±0.02 vs 7.24±0.02、7.13±0.01(均P<0.05)。
  • 低潮气量组PaO2 92.4±2.1 mmHg、PaO2/FiO2 440.0±10.2 mmHg,均高于模型组(61.8±2.3、274.3±21.4)与高潮气量组(76.6±2.2、364.7±10.5),均P<0.05。
  • 低潮气量组右心室收缩压31.3±0.4 mmHg,低于模型组34.0±1.0 mmHg与高潮气量组38.8±0.9 mmHg,均P<0.05。
  • 低潮气量组心率346.9±5.4 bpm、血压125.4±2.2 mmHg、右心室压力上升最大速率1393.3±30.3 mmHg/s,均高于模型组与高潮气量组(均P<0.05)。
  • 作者结论认为小潮气量机械通气可改善ARDS大鼠右心室血流动力学并保护右心功能。

适用人群与场景

  • 成年雄性Sprague-Dawley(SD)大鼠,经颈静脉注射油酸0.15 mL/kg复制ARDS模型;对照组注射等量生理盐水。

诊断标准与关键阈值

  • 建模后2小时以氧合指数(PaO2/FiO2)判断造模成功。
  • ARDS模型组PaO2/FiO2 294.3±5.9 mmHg显著低于对照组459.0±4.4 mmHg(P<0.01)。
  • ARDS模型组肺湿/干重比8.24±0.25、肺损伤评分0.60±0.03,均显著高于对照组4.48±0.13、0.12±0.02(均P<0.01)。

处置流程与药物剂量

  • 建模2小时后,低潮气量组以潮气量6 mL/kg机械通气4小时,高潮气量组以20 mL/kg机械通气4小时。
  • 对照组与ARDS模型组保持自主呼吸。
  • 机械通气4小时后测定心率、右心室收缩压、右心室压力上升最大速率、血压,并行动脉血气分析(pH、PaO2、PaCO2、PaO2/FiO2)。

红旗征与不能漏的情况

  • ARDS模型组大鼠建模后1小时出现呼吸窘迫症状,建模后2小时肺组织标本可见明显斑片状出血,对照组无此类改变。

研究设计与关键结果

  • 研究类型为动物实验,60只成年雄性SD大鼠按随机数字表分为对照组(n=20)、ARDS模型组(n=20)、低潮气量组(n=10)、高潮气量组(n=10)。
  • 低潮气量组pH 7.36±0.02,高于ARDS模型组7.24±0.02与高潮气量组7.13±0.01(均P<0.05)。
  • 低潮气量组PaO2 92.4±2.1 mmHg,高于ARDS模型组61.8±2.3 mmHg与高潮气量组76.6±2.2 mmHg(均P<0.05)。
  • 低潮气量组PaCO2 49.6±1.7 mmHg,低于ARDS模型组61.8±1.8 mmHg、高于高潮气量组33.6±1.3 mmHg(均P<0.05)。
  • 低潮气量组PaO2/FiO2 440.0±10.2 mmHg,高于ARDS模型组274.3±21.4 mmHg与高潮气量组364.7±10.5 mmHg(均P<0.05)。
  • 低潮气量组心率346.9±5.4 bpm,高于ARDS模型组302.3±10.1 bpm与高潮气量组265.5±12.2 bpm(均P<0.05)。
  • 低潮气量组血压125.4±2.2 mmHg,高于ARDS模型组110.0±2.5 mmHg与高潮气量组89.2±2.8 mmHg(均P<0.05)。
  • 低潮气量组右心室压力上升最大速率1393.3±30.3 mmHg/s,高于ARDS模型组1236.4±20.5 mmHg/s与高潮气量组896.1±19.5 mmHg/s(均P<0.05);右心室收缩压31.3±0.4 mmHg,低于ARDS模型组34.0±1.0 mmHg与高潮气量组38.8±0.9 mmHg(均P<0.05)。

证据类型、等级与局限

  • 证据类型:动物实验(大鼠ARDS模型),原文未给出证据等级。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为,小潮气量机械通气可改善ARDS大鼠右心室血流动力学参数并保护右心功能。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

OBJECTIVE: To explore the effect of different tidal volumes (VT) on the hemodynamics of right heart in acute respiratory distress syndrome (ARDS) rats induced by oleic acid (OA).

METHODS: Sixty adult male Sprague-Dawley (SD) rats were divided into control group (n = 20), ARDS model group (n = 20), low VT (LVT) group (n = 10) and high VT (HVT) group (n = 10) by random number table. ARDS model was reproduced by injecting OA 0.15 mL/kg through a jugular vein. The control group was given the same amount of normal saline. The success of modeling was judged by the oxygenation index (PaO2/FiO2) 2 hours after modeling, at the same time, the lung tissues were collected, the wet/dry weight (W/D) ratio was determined, and the lung histopathological changes were measured by lung injury score. The rats in the LVT group and HVT group were given mechanical ventilation with VT of 6 mL/kg or 20 mL/kg for 4 hours, respectively at 2 hours after modeling. The rats in the control group and the ARDS model group maintained spontaneous breathing. After mechanical ventilation for 4 hours, the heart rate (HR), right ventricular systolic pressure (RVSP), the maximum rate of rising of right ventricular pressure (dp/dt max), and the blood pressure (BP) were measured. Meanwhile, arterial blood samples were collected for blood gas analysis, including pH value, arterial partial pressure of oxygen (PaO2), arterial partial pressure of carbon dioxide (PaCO2) and PaO2/FiO2.

RESULTS: The rats in the ARDS model group showed symptoms of respiratory distress 1 hour after modeling, and the lung tissue samples showed obvious patchy bleeding 2 hours after modeling, while the control group showed no such changes. The PaO2/FiO2 in the ARDS model group was significantly lower than that in the control group [mmHg (1 mmHg = 0.133 kPa): 294.3±5.9 vs. 459.0±4.4, P < 0.01], and the lung W/D ratio and lung injury score were significantly higher (lung W/D ratio: 8.24±0.25 vs. 4.48±0.13, lung injury score: 0.60±0.03 vs. 0.12±0.02, both P < 0.01). It indicated that ARDS model was successfully reproduced. The arterial blood gas analysis and hemodynamic parameters of the ARDS model group were significantly worse than those of the control group. After 4-hour mechanical ventilation, the blood gas parameters of the LVT group were better than those of the ARDS model group and the HVT group [pH value: 7.36±0.02 vs. 7.24±0.02, 7.13±0.01; PaO2 (mmHg): 92.4±2.1 vs. 61.8±2.3, 76.6±2.2; PaCO2 (mmHg): 49.6±1.7 vs. 61.8±1.8, 33.6±1.3; PaO2/FiO2 (mmHg): 440.0±10.2 vs. 274.3±21.4, 364.7±10.5; all P < 0.05]. HR, BP and dp/dt max in the LVT group were significantly higher than those in the ARDS model group and the HVT group [HR (bpm): 346.9±5.4 vs. 302.3±10.1, 265.5±12.2; BP (mmHg): 125.4±2.2 vs. 110.0±2.5, 89.2±2.8; dp/dt max (mmHg/s): 1 393.3±30.3 vs. 1 236.4±20.5, 896.1±19.5; all P < 0.05], and RVSP was significantly lower than that in the ARDS model group and the HVT group (mmHg: 31.3±0.4 vs. 34.0±1.0, 38.8±0.9, both P < 0.05).

CONCLUSIONS: Mechanical ventilation with low VT can improve the hemodynamic parameters of the right ventricle and protect the function of the right heart in ARDS rats.

来源:Zhonghua Wei Zhong Bing Ji Jiu Yi Xue,查看原文。版权归原作者所有。

参考来源

  1. Liu J, Zhang H, Shi Y, et al. [Effects of mechanical ventilation with different tidal volumes on right ventricular hemodynamics in acute respiratory distress syndrome rats]. Zhonghua Wei Zhong Bing Ji Jiu Yi Xue. 2021. PMID: 33565400. doi:10.3760/cma.j.cn121430-20200710-00513

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。