文献速递呼吸衰竭与机械通气重症综合管理与镇静镇痛

机械通气患者膈肌回声密度:技术与结局描述

Diaphragm echodensity in mechanically ventilated patients: a description of technique and outcomes.
PubMed 文献 · Crit Care · 2021-02-16
一句话结论机械通气早期膈肌回声密度升高(ED50较基线增加≥10)与无呼吸机天数减少相关(中位46天 vs 53天,未校正P=0.03)。

该前瞻性研究开发了基于灰度值右偏分布(ED50、ED85)的膈肌超声回声密度定量技术,在34例机械通气患者中共采集104幅图像,并与10名年轻健康受试者比较。机械通气患者入ICU时膈肌ED85高于年轻健康受试者(中位56,IQR 42-84 vs 39,IQR 36-52,P=0.04)。早期ED50较基线增加≥10的患者至第60天无呼吸机天数更少(n=13,中位46天,IQR 0-52 vs n=21,中位53天,IQR 49-56,未校正P=0.03)。膈肌厚度增加和减少均与ED50随时间升高相关(校正P=0.03,条件R²=0.80),校正厚度变化后ED50升高与结局的关联仍存在。

要点

  • 机械通气患者入ICU时膈肌ED85高于年轻健康受试者(中位56,IQR 42-84 vs 39,IQR 36-52,P=0.04)。
  • 早期ED50较基线增加≥10的患者至第60天无呼吸机天数更少(n=13,中位46天,IQR 0-52 vs n=21,中位53天,IQR 49-56,未校正P=0.03)。
  • 膈肌厚度增加和减少均与ED50随时间升高相关(校正P=0.03,条件R²=0.80)。
  • 校正膈肌厚度变化后,ED50升高与不良结局的关联仍存在。
  • 该技术基于灰度值右偏分布定量(ED50、ED85),并报告了分析者内和分析者间测量可重复性。

适用人群与场景

  • 机械通气患者(前瞻性收集膈肌超声图像,共34例,104幅图像)
  • 10名年轻健康受试者作为对照

诊断标准与关键阈值

  • 膈肌回声密度基于灰度值右偏分布定量:第50百分位数(ED50)和第85百分位数(ED85)
  • 早期ED50较基线增加≥10定义为回声密度升高组

研究设计与关键结果

  • 研究类型:前瞻性收集膈肌超声图像,34例机械通气患者共104幅图像,并与10名年轻健康受试者比较
  • 基线(入ICU时)膈肌ED85在机械通气患者中高于年轻健康受试者(中位56,IQR 42-84 vs 39,IQR 36-52,P=0.04)
  • 早期ED50较基线增加≥10的患者至第60天无呼吸机天数更少(n=13,中位46天,IQR 0-52 vs n=21,中位53天,IQR 49-56,未校正P=0.03)
  • 膈肌厚度增加和减少均与ED50随时间升高相关(校正P=0.03,条件R²=0.80)
  • 校正膈肌厚度变化后,ED50升高与结局的关联仍存在
  • 记录了结局包括通气时长和ICU并发症(包括再插管、气管切开、延长通气或死亡)

证据类型、等级与局限

  • 证据类型:前瞻性观察性研究
  • 局限:原文未报告局限性

对床旁实践的改变

  • 作者认为机械通气早期膈肌回声密度升高与延长机械通气相关,膈肌厚度增加和减少均与回声密度升高相关。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

BACKGROUND: Acute increases in muscle sonographic echodensity reflect muscle injury. Diaphragm echodensity has not been measured in mechanically ventilated patients. We undertook to develop a technique to characterize changes in diaphragm echodensity during mechanical ventilation and to assess whether these changes are correlated with prolonged mechanical ventilation.

METHODS: Diaphragm ultrasound images were prospectively collected in mechanically ventilated patients and in 10 young healthy subjects. Echodensity was quantified based on the right-skewed distribution of grayscale values (50th percentile, ED50; 85th percentile, ED85). Intra- and inter-analyzer measurement reproducibility was determined. Outcomes recorded included duration of ventilation and ICU complications (including reintubation, tracheostomy, prolonged ventilation, or death).

RESULTS: Echodensity measurements were obtained serially in 34 patients comprising a total of 104 images. Baseline (admission) diaphragm ED85 was increased in mechanically ventilated patients compared to younger healthy subjects (median 56, interquartile range (IQR) 42-84, vs. 39, IQR 36-52, p = 0.04). Patients with an initial increase in median echodensity over time (≥ + 10 in ED50 from baseline) had fewer ventilator-free days to day 60 (n = 13, median 46, IQR 0-52) compared to patients without this increase (n = 21, median 53 days, IQR 49-56, unadjusted p = 0.03). Both decreases and increases in diaphragm thickness during mechanical ventilation were associated with increases in ED50 over time (adjusted p = 0.03, conditional R2 = 0.80) and the association between increase in ED50 and outcomes persisted after adjusting for changes in diaphragm thickness.

CONCLUSIONS: Many patients exhibit increased diaphragm echodensity at the outset of mechanical ventilation. Increases in diaphragm echodensity during the early course of mechanical ventilation are associated with prolonged mechanical ventilation. Both decreases and increases in diaphragm thickness during mechanical ventilation are associated with increased echodensity.

来源:Crit Care,查看原文。版权归原作者所有。

参考来源

  1. Coiffard B, Riegler S, Sklar MC, et al. Diaphragm echodensity in mechanically ventilated patients: a description of technique and outcomes. Crit Care. 2021. PMID: 33593412. doi:10.1186/s13054-021-03494-9

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。