文献速递呼吸衰竭与机械通气重症综合管理与镇静镇痛

自适应支持通气与非常规压力控制通气的机械功率比较——一项先导研究

Comparison of Mechanical Power During Adaptive Support Ventilation Versus Nonautomated Pressure-Controlled Ventilation-A Pilot Study.
PubMed 文献 · Crit Care Explor · 2021-02-15
一句话结论在被动机械通气的危重患者中,自适应支持通气相比压力控制通气可降低机械功率(15.1 vs 22.9 J/min),差异源于应用压力和呼吸频率的降低,而非潮气量。

该单中心、观察性前瞻性先导研究在荷兰一家非学术教学医院的ICU进行,纳入24例预计次日仍需有创通气的被动机械通气危重患者,比较自适应支持通气(仅由医护人员设置呼气末正压和吸入氧浓度,其余参数由呼吸机控制)与压力控制通气(由医护人员设置最大气道压、呼气末正压、吸入氧浓度和呼吸频率)的机械功率。每日计算机械功率3次,自适应支持通气的机械功率低于压力控制通气(15.1 [10.5-25.7] vs 22.9 [18.7-28.8] J/min;p=0.04),潮气量无差异,但最大气道压(p=0.012)和呼吸频率(p=0.012)在自适应支持通气下更低。作者认为自适应支持通气在降低呼吸机传递给呼吸系统的机械功率方面可能优于压力控制通气,该观察性先导研究结果需在更大规模、最好为随机临床试验中证实。

要点

  • 在被动机械通气的危重患者中,自适应支持通气的机械功率低于压力控制通气(15.1 [10.5-25.7] vs 22.9 [18.7-28.8] J/min;p=0.04)。
  • 自适应支持通气降低机械功率并非由于潮气量差异,而是最大气道压(p=0.012)和呼吸频率(p=0.012)更低。
  • 自适应支持通气下医护人员仅设置呼气末正压和吸入氧浓度,其余呼吸机参数由呼吸机控制;压力控制通气下还需设置最大气道压和呼吸频率。
  • 该研究为单中心观察性前瞻性先导研究,纳入24例预计次日仍需有创通气的被动机械通气患者,结果需在更大规模随机临床试验中证实。

适用人群与场景

  • 纳入24例预计次日仍需有创通气的被动机械通气危重患者,来自荷兰一家非学术教学医院的ICU。

处置流程与药物剂量

  • 自适应支持通气组:医护人员仅设置呼气末正压和吸入氧浓度,其余呼吸机参数由呼吸机控制。
  • 压力控制通气组:医护人员设置最大气道压、呼气末正压、吸入氧浓度和呼吸频率。
  • 机械功率每日计算3次。

研究设计与关键结果

  • 研究类型:单中心、观察性前瞻性先导研究,共纳入24例被动机械通气的危重患者。
  • 主要结果:自适应支持通气的机械功率低于压力控制通气(15.1 [10.5-25.7] vs 22.9 [18.7-28.8] J/min;p=0.04)。
  • 次要结果:潮气量无差异;最大气道压(p=0.012)和呼吸频率(p=0.012)在自适应支持通气下更低。

证据类型、等级与局限

  • 证据类型:单中心、观察性前瞻性先导研究。
  • 局限:作者指出该观察性先导研究结果需在更大规模、最好为随机临床试验中证实。

对床旁实践的改变

  • 作者认为,在被动机械通气的危重患者中,自适应支持通气在降低呼吸机传递给呼吸系统的机械功率方面可能优于压力控制通气。
  • 作者指出,机械功率的差异并非源于潮气量差异,而是应用压力和呼吸频率的降低。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

OBJECTIVES: The aim of this pilot study was to compare the amount of "mechanical power of ventilation" under adaptive support ventilation with nonautomated pressure-controlled ventilation.

DESIGN: Single-center, observational prospective pilot study adjoining unitwide implementation of adaptive support ventilation in our department.

SETTING: The ICU of a nonacademic teaching hospital in the Netherlands.

PATIENTS: Twenty-four passive invasively ventilated critically ill patients expected to need of invasive ventilation beyond the following calendar day.

MEASUREMENTS AND MAIN RESULTS: In patients under adaptive support ventilation, only positive end-expiratory pressure and Fio2 were set by the caregivers-all other ventilator settings were under control of the ventilator; in patients under pressure-controlled ventilation, maximum airway pressure (Pmax), positive end-expiratory pressure, Fio2, and respiratory rate were set by the caregivers. Mechanical power of ventilation was calculated three times per day. Compared with pressure-controlled ventilation, mechanical power of ventilation with adaptive support ventilation was lower (15.1 [10.5-25.7] vs 22.9 [18.7-28.8] J/min; p = 0.04). Tidal volume was not different, but Pmax (p = 0.012) and respiratory rate (p = 0.012) were lower with adaptive support ventilation.

CONCLUSIONS: This study suggests adaptive support ventilation may have benefits compared with pressure-controlled ventilation with respect to the mechanical power of ventilation transferred from the ventilator to the respiratory system in passive invasively ventilated critically ill patients. The difference in mechanical power of ventilation is not a result of a difference in tidal volume, but the reduction in applied pressures and respiratory rate. The findings of this observational pilot study need to be confirmed in a larger, preferably randomized clinical trial.

来源:Crit Care Explor,查看原文。版权归原作者所有。

参考来源

  1. Buiteman-Kruizinga LA, Mkadmi HE, Schultz MJ, et al. Comparison of Mechanical Power During Adaptive Support Ventilation Versus Nonautomated Pressure-Controlled Ventilation-A Pilot Study. Crit Care Explor. 2021. PMID: 33604578. doi:10.1097/CCE.0000000000000335

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。