VqSOFA对急诊疑似脓毒症患者28天死亡率的预后准确性
该研究在Ramathibodi医院急诊科纳入1,139例疑似脓毒症患者,用初始生命体征和实验室值计算VqSOFA、qSOFA和SOFA评分,以28天死亡为主要终点比较预后准确性。VqSOFA的AUROC为0.851(95%CI 0.813-0.889),高于qSOFA的0.813(95%CI 0.772-0.854)和SOFA的0.728(95%CI 0.671-0.784)。以VqSOFA≥3为界值,敏感度74.6%、特异度82.5%、阳性似然比4.25。VqSOFA≥3与28天生存概率低及24小时内使用血管活性药和呼吸机几率升高相关。结论认为VqSOFA对28天死亡及血管活性药和机械通气使用的预测优于qSOFA和SOFA。
要点
- 急诊疑似脓毒症患者中,VqSOFA预测28天死亡的AUROC为0.851(95%CI 0.813-0.889),优于qSOFA的0.813和SOFA的0.728。
- VqSOFA≥3为界值时,敏感度74.6%、特异度82.5%、阳性似然比4.25,可作为急诊风险分层参考。
- VqSOFA≥3与28天生存概率低及24小时内使用血管活性药和机械通气几率升高相关。
- 该研究为单中心急诊队列,VqSOFA的界值及临床推广需外部验证。
- 原文未报告VqSOFA的具体计算公式中乳酸的单位和阈值,使用时需对照原研究定义。
适用人群与场景
- 在Ramathibodi医院急诊科就诊的疑似脓毒症患者,共纳入1,139例。
诊断标准与关键阈值
- VqSOFA评分由静脉乳酸水平联合qSOFA评分构成,具体计算方法和乳酸阈值原文未详细说明。
- 以VqSOFA≥3作为预测28天死亡的界值,敏感度74.6%、特异度82.5%、阳性似然比4.25。
- qSOFA和SOFA评分使用初始生命体征和实验室值计算。
处置流程与药物剂量
- 原文未提及基于VqSOFA的具体处置流程或药物剂量方案。
红旗征与不能漏的情况
- VqSOFA≥3提示28天生存概率低,且24小时内使用血管活性药和机械通气的几率升高,需警惕病情恶化。
研究设计与关键结果
- 研究类型为单中心急诊队列研究,纳入1,139例疑似脓毒症患者,其中118例在28天内死亡。
- VqSOFA预测28天死亡的AUROC为0.851(95%CI 0.813-0.889),qSOFA为0.813(95%CI 0.772-0.854),SOFA为0.728(95%CI 0.671-0.784)。
- VqSOFA≥3的敏感度74.6%、特异度82.5%、阳性似然比4.25。
- VqSOFA≥3与28天生存概率低及24小时内使用血管活性药和呼吸机几率升高相关。
证据类型、等级与局限
- 证据类型为单中心观察性队列研究,原文未报告证据等级或推荐强度。
- 局限性包括单中心设计,原文未提及外部验证。
对床旁实践的改变
- 在急诊疑似脓毒症患者中,可考虑使用VqSOFA评分(静脉乳酸联合qSOFA)辅助预测28天死亡风险,VqSOFA≥3提示高风险。
- VqSOFA不能替代临床判断,其界值和预测效能需在本地人群中验证。
- 原文未提供基于VqSOFA改变治疗决策的具体建议。
指南或共识出处
- 原文未提及
以上提炼依据论文摘要(全文未开放获取,或许可不允许翻译转载);全文请点「阅读原文」。
英文原文(摘要)· 点击展开
BACKGROUND: Sepsis screening in the emergency department (ED) is challenging. The quick Sequential Organ Failure Assessment (qSOFA) score had poor accuracy for predicting mortality in both the intensive care unit and ED. High lactate levels were associated with an increased mortality. However, a previous study using lactate levels in combination with the qSOFA score did not observe a meaningful improvement in predictive accuracy. This study assessed the prognostic accuracy of venous lactate levels plus the qSOFA (VqSOFA) score for predicting 28-day mortality.
METHODS: Patients who visited the Ramathibodi ED with suspected sepsis were enrolled. The VqSOFA, qSOFA, and Sequential Organ Failure Assessment (SOFA) scores were calculated using the initial vital signs and laboratory values. Prognostic accuracy was measured using the area under the receiver operating characteristic (AUROC) curve of the VqSOFA score and Sepsis-3 criteria for predicting 28-day mortality.
RESULTS: In total, 1,139 patients were enrolled, 118 of whom died within 28 days of admission. The AUROCs of the VqSOFA, qSOFA, and SOFA scores were 0.851 (95% CI 0.813-0.889), 0.813 (95% CI 0.772-0.854), and 0.728 (95% CI 0.671-0.784), respectively. Using VqSOFA score ≥ 3 as the cutoff, the sensitivity, specificity, and positive likelihood ratio were 74.6%, 82.5%, and 4.25%, respectively. VqSOFA ≥ 3 was linked to a low probability of 28-day survival and higher odds of vasopressor and ventilator use within 24 h.
CONCLUSIONS: VqSOFA was more predictive of 28-day mortality and vasopressor and mechanical ventilator use than the qSOFA and SOFA scores.
参考来源
- Suttapanit K, Wisan M, Sanguanwit P, et al. Prognostic Accuracy of VqSOFA for Predicting 28-day Mortality in Patients with Suspected Sepsis in the Emergency Department. Shock. 2021. PMID: 33577246. doi:10.1097/SHK.0000000000001754
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。