文献速递重症综合管理与镇静镇痛心脑血管急症

COVID-19患者床旁血管超声自发性回声对比与主要血栓事件发生的关系

Presence of Spontaneous Echo Contrast on Point-of-Care Vascular Ultrasound and the Development of Major Clotting Events in Coronavirus Disease 2019 Patients.
PubMed 文献 · Crit Care Explor · 2021-01-08
一句话结论COVID-19 ICU患者床旁静脉超声发现自发性回声对比提示高粘滞血症和血栓事件风险增加。

该回顾性队列研究纳入39例ICU确诊COVID-19成人患者,回顾48次静脉超声检查,由两名评审盲法评估自发性回声对比。自发性回声对比与血清粘度升高(p=0.0056)和高纤维蛋白原血症(p=0.0045)相关。致密自发性回声对比患者36%、阳性自发性回声对比患者33%发生显著血栓事件,而阴性者仅17%;19%的自发性回声对比患者在主要血栓事件后发生心脏骤停,阴性组无血栓相关心脏骤停。床旁静脉超声易于操作且判读可靠,自发性回声对比可作为COVID-19患者高凝状态和血栓风险的床旁警示信号。

要点

  • COVID-19 ICU患者床旁静脉超声发现自发性回声对比时,致密者36%、阳性者33%发生显著血栓事件,阴性者17%。
  • 自发性回声对比患者中19%在主要血栓事件后发生心脏骤停,阴性组无血栓相关心脏骤停。
  • 自发性回声对比与血清粘度相关:致密、阳性、阴性组均值分别为2.64、2.54、2.04 cP(阳性 vs 阴性 p=0.0056)。
  • 自发性回声对比与高纤维蛋白原血症相关:致密、阳性、阴性组均值分别为726.6、668.5、566.6 mg/dL(致密 vs 阴性 p=0.0045)。
  • 自发性回声对比与左右心功能及D-二聚体、外部血栓弹力图最大溶解、血小板计数、C反应蛋白、白介素-6无关联。

适用人群与场景

  • ICU收治的成人确诊COVID-19患者,且在ICU期间接受过血管超声检查。
  • 回顾性分析39例患者共48次静脉超声检查。

诊断标准与关键阈值

  • 原文未提及

处置流程与药物剂量

  • 原文未提及

红旗征与不能漏的情况

  • 床旁静脉超声发现自发性回声对比(尤其致密自发性回声对比)提示高粘滞血症和血栓事件风险增加,需警惕后续主要血栓事件及血栓后心脏骤停。

研究设计与关键结果

  • 研究类型:回顾性队列研究;样本量:39例成人患者、48次静脉超声;中心数:单中心(大型三级学术医疗中心)。
  • 干预/暴露:床旁静脉超声评估自发性回声对比,由两名评审盲法判读;对照:无自发性回声对比。
  • 主要终点:自发性回声对比与血清粘度相关(致密、阳性、阴性组均值2.64、2.54、2.04 cP;阳性 vs 阴性 p=0.0056)。
  • 主要终点:自发性回声对比与高纤维蛋白原血症相关(致密、阳性、阴性组均值726.6、668.5、566.6 mg/dL;致密 vs 阴性 p=0.0045)。
  • 血栓事件:致密自发性回声对比患者36%、阳性自发性回声对比患者33%发生显著血栓事件,阴性者17%。
  • 心脏骤停:19%的自发性回声对比患者在主要血栓事件后发生心脏骤停,阴性组无血栓相关心脏骤停。
  • 无关联:自发性回声对比与左右心功能及D-二聚体、外部血栓弹力图最大溶解、血小板计数、C反应蛋白、白介素-6无关联。

证据类型、等级与局限

  • 证据类型:回顾性队列研究(单中心)。
  • 局限:样本量小(39例患者、48次超声),回顾性设计,单中心,未提及盲法以外的混杂控制。

对床旁实践的改变

  • 在COVID-19 ICU患者中,床旁静脉超声可常规用于观察自发性回声对比,作为高粘滞血症和血栓风险的床旁提示。
  • 发现自发性回声对比(尤其致密)时,应提高对主要血栓事件及血栓后心脏骤停的警惕。
  • 自发性回声对比与D-二聚体、血小板计数、C反应蛋白、白介素-6等实验室指标无关联,不能以这些指标替代超声评估。

指南或共识出处

  • 原文未提及

以上提炼依据论文摘要(全文未开放获取,或许可不允许翻译转载);全文请点「阅读原文」。

英文原文(摘要)· 点击展开

UNLABELLED: The presence of spontaneous echo contrast on ultrasonography is a predisposition to increased thromboembolic risk. The purpose of this study was to assess for the prevalence and consequences of spontaneous echo contrast on point-of-care vascular ultrasound in coronavirus disease 2019.

DESIGN SETTING AND PATIENTS: This was a retrospective cohort study of 39 adult patients admitted to the ICU with a confirmed coronavirus disease 2019 diagnosis at a large tertiary-care academic medical center. Patients were included if they had undergone a vascular ultrasound examination during their ICU admission. Overall, 48 venous ultrasound studies among the 39 patients were reviewed in blinded fashion by two reviewers for the presence of venous spontaneous echo contrast, and charts were analyzed for laboratory data and outcomes.

MEASUREMENTS AND MAIN RESULTS S: pontaneous echo contrast correlated with serum viscosity (mean values of 2.64, 2.54, and 2.04 cP for dense spontaneous echo contrast, spontaneous echo contrast , and no spontaneous echo contrast, respectively, with a p value of 0.0056 for spontaneous echo contrast compared with negative spontaneous echo contrast) and hyperfibrinogenemia (mean values of 726.6, 668.5, and 566.6 mg/dL for dense spontaneous echo contrast, positive spontaneous echo contrast, and negative spontaneous echo contrast, respectively, with a p value of 0.0045 for dense spontaneous echo contrast compared with negative spontaneous echo contrast). About 36% of patients with dense spontaneous echo contrast and 33% of individuals with positive spontaneous echo contrast experienced significant clotting events compared with 17% of those with negative spontaneous echo contrast. A total of 19% of patients with spontaneous echo contrast suffered a cardiac arrest following a major clotting event, and there were no cardiac arrests from clotting events in the negative spontaneous echo contrast group. There was no association with the presence of spontaneous echo contrast and right or left cardiac function or other laboratory values such as d-dimer, external thromboelastometry - maximum lysis, platelet counts, C-reactive protein, or interleukin-6.

CONCLUSIONS: Point-of-care venous ultrasonography is easily performed and reliably interpreted for visualization of spontaneous echo contrast. The presence of spontaneous echo contrast in patients with coronavirus disease 2019 is associated with hyperviscosity and increased rates of thrombotic events and complications.

来源:Crit Care Explor,查看原文。版权归原作者所有。

参考来源

  1. Connor-Schuler R, Daniels L, Coleman C, et al. Presence of Spontaneous Echo Contrast on Point-of-Care Vascular Ultrasound and the Development of Major Clotting Events in Coronavirus Disease 2019 Patients. Crit Care Explor. 2021. PMID: 33458687. doi:10.1097/CCE.0000000000000320

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。