文献速递心脑血管急症重症综合管理与镇静镇痛

偏侧周期性放电相关的血流动力学变化:近红外光谱与连续脑电图研究

Hemodynamic Changes Associated with Lateralized Periodic Discharges: A Near-Infrared Spectroscopy and Continuous EEG Study.
PubMed 文献 · Neurocrit Care · 2020-12-01
一句话结论LPDs同侧大脑氧饱和度升高,频率越高氧饱和度越低,提示LPDs增加同侧氧耗,高频LPDs可能提示氧供不足。

结果发现LPDs侧大脑氧饱和度高于非LPDs侧(57% vs 52%,p=0.03);LPDs主频率越高,同侧脑氧饱和度(r=-0.55,p=0.022)和氧合血红蛋白浓度(r=-0.52,p=0.033)越低。记录期间出现癫痫发作的患者(64.7%)中,LPDs侧总血红蛋白和氧合血红蛋白更低。提示LPDs增加同侧氧耗,可能存在频率阈值使氧耗超过氧供。

要点

  • LPDs侧大脑氧饱和度高于对侧(57% vs 52%,p=0.03),提示LPDs增加同侧代谢需求。
  • LPDs主频率越高,同侧脑氧饱和度越低(r=-0.55,p=0.022),氧合血红蛋白也越低(r=-0.52,p=0.033)。
  • 记录期间出现癫痫发作的患者占64.7%,其LPDs侧总血红蛋白(28.2 vs 37.8 μmol/L,p=0.049)和氧合血红蛋白(15.5 vs 24.2 μmol/L,p=0.033)更低。
  • 总血红蛋白、氧合血红蛋白和脱氧血红蛋白在LPDs侧的变化趋势未达统计学显著。
  • 作者推断可能存在LPDs频率阈值,当氧需超过氧供时脑氧饱和度下降。

适用人群与场景

  • ICU收治的连续脑电图检出LPDs的成人患者(原文未提排除标准)。

诊断标准与关键阈值

  • LPDs诊断依据连续脑电图;原文未提及具体诊断标准或评分界值。

处置流程与药物剂量

  • 原文未提及

红旗征与不能漏的情况

  • 原文未提及

研究设计与关键结果

  • 干预与对照:无干预,比较LPDs侧与非LPDs侧半球,以及不同LPDs频率与NIRS参数的关系。
  • 主要终点结果:LPDs侧大脑氧饱和度高于非LPDs侧(57% vs 52%,p=0.03)。
  • 关键次要终点:LPDs主频率与同侧脑氧饱和度负相关(r=-0.55,p=0.022),与氧合血红蛋白负相关(r=-0.52,p=0.033);记录期间出现癫痫发作的患者(64.7%)中LPDs侧总血红蛋白(28.2 μmol/L vs 37.8 μmol/L,p=0.049)和氧合血红蛋白(15.5 μmol/L vs 24.2 μmol/L,p=0.033)更低。
  • 不良事件:原文未提及。

证据类型、等级与局限

  • 局限:样本量小、单中心、观察性设计无法确定因果关系;NIRS为无创监测,原文未提及阈值或验证。

对床旁实践的改变

  • 对ICU内连续脑电图检出LPDs的患者,可考虑同步NIRS监测双侧额区脑氧饱和度,以评估LPDs侧氧代谢变化。
  • LPDs频率较高时,同侧脑氧饱和度可能下降,提示需关注氧供是否充足;但原文未给出干预阈值或治疗建议,不能据此改变抗癫痫药物使用。
  • 记录期间出现癫痫发作的患者中LPDs侧总血红蛋白和氧合血红蛋白更低,提示需关注癫痫发作与脑氧代谢的关系。
  • 原文未提及LPDs频率阈值或NIRS阈值用于临床决策,不能将相关性数值作为决策阈值。

指南或共识出处

  • 原文未提及

以上提炼依据论文摘要(全文未开放获取,或许可不允许翻译转载);全文请点「阅读原文」。

英文原文(摘要)· 点击展开

BACKGROUND: Lateral periodic discharges (LPDs) have been recognized as a common electroencephalographic (EEG) pattern in critically ill patients. However, management decisions in these patients are still a challenge for clinicians. This study investigates hemodynamic changes associated with LPDs and evaluates if this pattern is likely to represent an ictal, interictal, or ictal-interictal continuum phenomenon via non-invasive near infra-red spectroscopy (NIRS) with concurrent with continuous EEG.

METHODS: Seventeen patients admitted to the intensive care unit with LPDs on continuous electroencephalogram (EEG) were included. Participants engaged in NIRS recording-with scalp probes on right and left frontal regions simultaneously. Associations between LPDs laterality, primary frequency, NIRS a of cerebral oxygen saturation (SO2), total hemoglobin concentration (tHb), oxygenated hemoglobin concentration (O2Hb), de-oxygenated hemoglobin concentration (HHb), and variables in participant medical history were studied.

RESULTS: Hemispheres with LPDs showed higher overall SO2 when compared to non-LPDs hemispheres (57% vs 52%, p = 0.03). Additionally, mildly increased tHb, O2Hb, and mildly decreased HHb concentrations were detected in the hemisphere showing LPDs, but changes were not statistically significant. A higher primary frequency of LPDs was associated with lower cerebral SO2 (Pearson correlation r = - 0.55, p = 0.022) and O2Hb (Pearson correlation r = - 0.52, p = 0.033). In patients with seizure during their EEG recording (64.7%), lower tHb (28.2 μmol/L vs 37.8 μmol/L, p = 0.049) and O2Hb (15.5 μmol/L vs 24.2 μmol/L, p = 0.033) were recorded in the LPDs hemisphere.

CONCLUSIONS: This study demonstrates an increased cerebral SO2 in the hemisphere with LPDs, and decreased SO2 and O2Hb when the frequency of LPDs increases. The findings indicate that LPDs increase oxygen demand on the ipsilateral hemisphere. We infer that a threshold of LPDs frequency might exit, when the cerebral oxygen demand begins to supersede the ability of delivery, and saturation decreases.

来源:Neurocrit Care,查看原文。版权归原作者所有。

参考来源

  1. Winslow N, George M, Michalos A, et al. Hemodynamic Changes Associated with Lateralized Periodic Discharges: A Near-Infrared Spectroscopy and Continuous EEG Study. Neurocrit Care. 2020. PMID: 33263144. doi:10.1007/s12028-020-01154-4

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。