文献速递呼吸衰竭与机械通气重症综合管理与镇静镇痛

共享呼吸机交叉污染评估

Evaluating cross contamination on a shared ventilator.
PubMed 文献 · Emerg Med J · 2020-12-04
一句话结论在特定管路配置下,单台呼吸机可同时支持4例模拟患者24小时而无路内交叉污染。

本研究用四套并联标准管路连接四个2L麻醉气囊模拟患者,每套管路含热湿交换过滤器及呼气支细菌/病毒过滤器。模拟肺1接种粘质沙雷菌,运行24小时。结果患者2、3、4的灌洗培养及呼气支远端、连接器、过滤器前管路培养在24和48小时均无粘质沙雷菌生长。结论认为该特定管路配置下,单台呼吸机维持4例患者24小时不产生交叉污染是合理的。

要点

  • 在每例患者管路含热湿交换过滤器且呼气支加装细菌/病毒过滤器的配置下,模拟肺2、3、4在24和48小时培养均无粘质沙雷菌生长。
  • 呼气支远端、呼气支连接器及呼气支过滤器前管路在24和48小时均无粘质沙雷菌生长。
  • 该研究为体外模拟实验,使用2L麻醉气囊模拟患者,运行时间为24小时,非真实临床人群。
  • 结论提示在特定管路配置下单台呼吸机支持4例患者24小时不产生交叉污染是合理的,但仅限该配置。

适用人群与场景

  • 原文为体外模拟实验,使用2L麻醉气囊模拟患者,非真实急诊或ICU患者;原文未明确临床适用人群与排除人群。

诊断标准与关键阈值

  • 原文未提及

处置流程与药物剂量

  • 管路配置:四套无菌、并联标准管路连接四个2L麻醉气囊,每例患者连接热湿交换过滤器(Heat and Moisture Exchange filter),呼气支另加细菌/病毒过滤器。
  • 模拟肺1接种粘质沙雷菌分离株,管路运行24小时。
  • 每例模拟肺及呼气支管路三个点用肉汤灌洗并培养,所有培养孵育48小时,24小时进行传代。

红旗征与不能漏的情况

  • 原文未提及

研究设计与关键结果

  • 研究类型:体外模拟实验;样本量:4个模拟肺(2L麻醉气囊);无多中心信息。
  • 干预:四套并联标准管路连接单台呼吸机,每例含热湿交换过滤器,呼气支加细菌/病毒过滤器;模拟肺1接种粘质沙雷菌。
  • 主要结果:模拟肺2、3、4灌洗培养在24和48小时均无粘质沙雷菌生长。
  • 次要结果:呼气支远端、呼气支连接器及呼气支过滤器前管路培养在24和48小时均无粘质沙雷菌生长。

证据类型、等级与局限

  • 证据类型:体外模拟实验(非RCT、非临床研究);原文未给出证据等级或推荐强度。
  • 局限:体外模拟使用2L麻醉气囊而非真实患者;单中心?原文未提及中心数;样本量小(4个模拟肺);仅测试一种细菌(粘质沙雷菌);仅运行24小时;结论仅适用于所描述的特定管路配置。

对床旁实践的改变

  • 该体外模拟结果提示,在每例患者管路含热湿交换过滤器且呼气支加装细菌/病毒过滤器的特定配置下,单台呼吸机支持4例患者24小时可能不产生路内交叉污染。
  • 原文未提供临床患者数据,不能直接推广至真实急诊或ICU患者;适用与不适用人群原文未明确。
  • 常见陷阱:将体外模拟结果等同于临床推荐;忽略原文限定的特定管路配置和24小时运行时间;原文未测试其他病原体或更长时间。

指南或共识出处

  • 原文未提及指南或共识;来源期刊:Emerg Med J(PubMed)。

以上提炼依据论文摘要(全文未开放获取,或许可不允许翻译转载);全文请点「阅读原文」。

英文原文(摘要)· 点击展开

BACKGROUND: Disasters have the potential to cause critical shortages of life-saving equipment. It has been postulated that during patient surge, multiple individuals could be maintained on a single ventilator. This was supported by a previous trial that showed one ventilator could support four sheep. The goal of our study is to investigate if cross contamination of pathological agents occurs between individuals on a shared ventilator with strategically placed antimicrobial filters.

METHODS: A multipatient ventilator circuit was assembled using four sterile, parallel standard tubing circuits attached to four 2 L anaesthesia bags, each representing a simulated patient. Each 'patient' was attached to a Heat and Moisture Exchange filter. An additional bacterial/viral filter was attached to each expiratory limb. 'Patient-Lung' number 1 was inoculated with an isolate of Serratia marcescens, and the circuit was run for 24 hours. Each 'lung' and three points in the expiratory limb tubing were washed with broth and cultured. All cultures were incubated for 48 hours with subcultures performed at 24 hours.

RESULTS: Washed cultures of patient 2, 3 and 4 failed to demonstrate growth of S. marcescens. Cultures of the distal expiratory tubing, expiratory limb connector and expiratory limb prefilter tubing yielded no growth of S. marcescens at 24 or 48 hours.

CONCLUSION: Based on this circuit configuration, it is plausible to maintain four individuals on a single ventilator for 24 hours without fear of cross contamination.

来源:Emerg Med J,查看原文。版权归原作者所有。